Showing results: 1396 - 1410 of 1667 items found.
-
40-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-877A-102 -
Pickering Interfaces Ltd.
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-877A-002 -
Pickering Interfaces Ltd.
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
SMX-4XXX (Matrix Switches) -
AMETEK VTI Instruments
The VTI SMX-4xxx Series of matrix cards deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Available models with software configurable switch subsystems increase flexibility and help control costs by allowing a single module to be used for different testing requirements. Embedded virtual schematic control further simplifies setup and debugging, allowing all relays to be engaged independent of application software.
-
42-585A-001 -
Pickering Interfaces Ltd.
Our model 40-585A, along with the following models 40-584A, 40-586B and 40-587A are high-density single pole PXI matrices each with 256 crosspoints. All models use gold-plated contact electromechanical relays. This module is also available in PXIe format (42-585A-001).
-
42-586B-001 -
Pickering Interfaces Ltd.
Our model 40-586B-001, along with the following models 40-584A, 40-585A and 40-587A are high-density single pole PXI or PXIe matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays.
-
42-584A-001 -
Pickering Interfaces Ltd.
Our model 40-584A, along with the following models 40-585A, 40-586B and 40-587A are high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. This module is also available in PXIe format (42-584A-001).
-
40-584A-001 -
Pickering Interfaces Ltd.
Our model 40-584A, along with the following models 40-585A, 40-586B and 40-587A are high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. This module is also available in PXIe format (42-584A-001).
-
M9164A -
Keysight Technologies
M9164A 2X16 PXIe switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution.
-
M9165C -
Keysight Technologies
M9165C 2X8 PXIe switch matrix, 300 KHz to 18 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution.
-
34933A -
Keysight Technologies
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
782835-37 -
NI
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.