Product
PowerNet Tester
-
The PowerNet Tester (BNT) is designed to test batteries, ultracaps and all other types of electrochemical power sources for 14 V and 42 V power net systems. Designed to test vehicle system batteries for 14V and 42V power net systems. But they may also be used for testing all other types of electrochemical power sources just by setting the required current and voltage values.
-
Product
Multiplexer
-
The Ivium Technologies electrochemical multiplexer can work individual cells with 2, 3 and 4 electrodes and a WE2 (BipotentioStat, optional). Each multiplexer has 8 channels and the multiplexer units can be stacked so that up to 64 channels can be controlled sequentially by a single potentiostat.
-
Product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
-
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
Product
Single Channel Potentiostats
PARSTAT Series
-
The PARSTAT-series of potentiostats is defined by offering superior performance as standard. The PARSTAT4000A and PARSTAT3000A complement each other.Both of these single channel potentiostats operate in VersaStudio software with all techniques available, including Electrochemical Impedance Spectroscopy up to high frequency.
-
Product
Trace Moisture Analyzer
PPM1
-
Model PPM1 is a trace moisture analyzer designed specifically for monitoring moisture levels in dew point and PPM units. This trace moisture analyzer utilizes an electro-chemical (P205) sensor in combination with a proprietary semi permeable diffusion membrane.
-
Product
Long Term Test Kit
-
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
Product
Solid Pins
-
Advanced Probing Systems, Inc.
APS produces electro-chemically machined pins in diameters between .020"-.040" in a variety of materials for use in various applications. These “large diameter pins” are used in various medical applications, industrial applications, board testing, LED & LCD test and as components in small tools. APS’s design services can help you select the optimal material from tungsten, beryllium-copper, Paliney 7® or various stainless steel alloys or work with the material of your choice. Pins can be produced with either a sharp or radius (rounded) tip. Tapers can be highly polished, slightly polished, matte or neutral in finish.
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Water Quality Products
-
When you need to perform critical water testing, look to us for an extensive selection of electrochemical meters, controllers, probes, electrodes, test kits, buffers, and standards. Our field and laboratory instrumentation include water analysis instruments for dissolved oxygen, temperature, pH, conductivity, salinity, and turbidity.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
Single Channel Potentiostats
12XX Series
-
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
Product
Potentiostat/Galvinostat Electrochemical Instuments
-
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
Product
Solid Tungsten Probe Tips
ST Series
-
The ST SERIESof probe tips, available from GGB Industries, Inc., are precision crafted from a 0.020 inch (0.51mm) diameter solid tungsten shaft that is electrochemically sharpened to a specified point. These durable, 1.5 inch long solid tungsten shaft probe tips are for use in most standard micropositioners when probing an integrated circuit, pad, or line. A variety of radius point sizes from 0.5 microns to 10 microns are available to accommodate any probing need.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Flow Cell Kit
QCMT
-
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
Product
Carbon Monoxide Detectors
Inspector CO Detectors
-
Sensorcon, Sensing Solutions by Molex believes in the importance of a dependable gas detector. Featuring proprietary engineering & software, our Inspector Series utilizes electrochemical sensors for fast & accurate measurements of CO.
-
Product
Combo Gas Monitor
Z-Gard Combo Gas Monitor
-
A cost-efficient monitor for underground garages and ventilation control, the Z-Gard Combo Gas Monitor uses an electrochemical sensor to detect carbon monoxide. The unit features local audio/visual alarm status indicators and it can be configured to interface with air-handling equipment to control air quality within a building.
-
Product
Oxygen Analyzers for Process, Industrial & Fail-Safe Applications
-
The O2 analyzers from PST offer oxygen sensor technologies such as zirconium dioxide, thermo-paramagnetic and electrochemical. These highly reliable oxygen analyzers provide various installation options such as bench, panel, rack and wall mounting.
-
Product
HiL Simulators
NovaCarts Battery
-
Exact cell simulation for validating battery management systems (BMS). "NovaCarts Battery" represents one of the most powerful and precise cell simulation systems on the market. This is leveraged by the modular and scalable HiL system to create optimum conditions for developing new battery management functions such as state-of-charge (SoC) and state-of-health (SoH) controls, active cell balancing and electrochemical impedance spectroscopy.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
Oxygen Sensors for Medical Products
-
USA manufactured electrochemical galvanic oxygen sensors (O2 sensors) for use in ventilators, anaesthesia machines, incubators, oxygen monitors and breathing gas mixes.Approved FDA, MDSAP, ISO13485, ISO9001 replacement oxygen sensors for respiratory medical devices with lifetimes up to 60 months. .
-
Product
Software
-
TestPoint-based software for control, measurement and evaluation of electrochemical measurements, requires MS WindowsTM supports or interfaces,. CPC manages potentiostat control, data recording and data evaluation.Features: Up to 6 measurements channels, fast data access up to 300,000 data points per second. The evaluation allows differentiation, Tafel slope evaluation and other helpful routinesCPC runs with many multi-function AD/DA converter boards. It requires MS Windows (TM)
-
Product
Electrical Resistance (ER) Monitoring
-
The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.
-
Product
Constant Temperature Humidity Battery Test Chamber
-
Guangdong Test EQ Equipment co., Ltd.
- Battery-Specific Thermal Management: Dual-compressor cascade cooling (-40°C stability) and ceramic heaters for rapid high-temperature recovery.- Precision Electrochemical Control: Integrated battery cyclers with CAN/Modbus protocols, supporting SOP (State of Power), SOH (State of Health), and DCR (Direct Current Resistance) monitoring.- Safety-Centric Design-meet Hazard Level: Chambers are designed with Fire-resistant stainless steel interior, fire suppression,nitrogen purge system, and emergency power cutoff for thermal runaway prevention .- Data Acquisition & AI Analytics: Real-time logging of voltage, current, temperature, and pressure via LabVIEW/Python APIs. AI-driven anomaly detection reduces test cycles by 30%.- Energy Efficiency and Energy Storage: Heat recovery during discharge cycles cuts energy use by 25% (ISO 50001 compliant).
-
Product
Hazardous Area Gas Detector
Meridian
-
Teledyne Gas & Flame Detection
Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian universal gas detector utilizes a single detector head to easily accept all sensor types. There is no requirement for distinct personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector. The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Teledyne Gas and Flame Detection, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Teledyne Gas and Flame Detection while maintaining ease of use and peace of mind.
-
Product
EIS Battery Analyzer
BA8100
-
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
Product
Electrochemical Detector
800D
-
The Model 800C series is designed for electrochemical detection. This instrument can be used for monitoring the current passing through a flow cell in liquid chromatography/electrochemistry and in-flow injection analysis, as well as other electroanalytical applications.
-
Product
Scanning Probe Workstations
-
BioLogic has over 25 years of experience producing scanning probe electrochemistry instruments. Initially this included a number of single technique instruments, with the first modular scanning electrochemical workstation, the M370, introduced in 2006, under the Uniscan name.Scanning probe electrochemistry has found use in academic and commercial research settings. It is applicable in any field in which bulk electrochemical measurements have been used. Scanning probe electrochemistry has found widespread use in: Corrosion and coatings, Biology, including biosensors and biotechnology, Batteries, fuel cells and photovoltaics, Materials, Catalysis