Process Ozone Instruments
Teledyne Advanced Pollution Instrumentation (TAPI)
All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring. Below is a list of a range of Teledyne API process ozone instruments.
-
Unlisted Product
Process and Safety Ozone Monitor
Model 465L +O2
-
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions. An integral micro fuel cell sensor provides accurate, continuous monitoring of O2 and allows measuring of both gases in a single instrument.The Model 465L + O2 has been designed to deliver excellent performance, high reliability and simple operation. Operating parameters can be easily set up in the field using the operator-friendly menu driven software.
-
Unlisted Product
Process Ozone Monitor
Model 454
-
Teledyne Advanced Pollution Instrumentation
The Model 454 is a microprocessor based gas monitor for measuring mid to high concentrations of ozone in oxygen or air. Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.The 454 Series is available in full scale ranges from 0-5% w/w to 0-25% w/w, and is factory calibrated in accordance with International Ozone Association standards. The measurement principle is based on the absorption of UV light at 254nm. As the sample containing ozone flows through the absorption cell, it is exposed to UV light at the 254nm wavelength. The amount of absorption by ozone is measured by a narrow bandwidth UV detector.
-
Unlisted Product
Process Ozone Sensor
Model 452
-
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor-based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature (with pressure compensation up to 3 Bar Absolute dependent upon range). Its compact size allows for easy installation in process applications.The flow pattern is a straight through design (eliminating turns and elbows), reducing exposed surface area. The 452 uses detectors which have a very narrow band of spectral sensitivity, eliminating the need for UV band pass filters which are subject to deterioration by UV or humidity.
-
Unlisted Product
Process Ozone Monitor
Model 465H
-
Teledyne Advanced Pollution Instrumentation
The Model 465H is a microprocessor based high concentration ozone monitor for measuring ozone in process gas streams in water treatment, food processing, and research applications. The 465H has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465H is available in a 19” rack mount or NEMA 4X wall mount enclosure.The sensor module contained in the Model 465H uses detectors which have a very narrow band of spectral sensitivity, eliminating the need for UV band pass filters which are subject to deterioration by UV or humidity. Two detectors are used: one for the ozone measurement, and the other to compensate for changes in UV lamp intensity. This unique design provides a sensor which will operate for extended periods without calibration ormaintenance.
-
Unlisted Product
Process Ozone Monitor
Model 465M
-
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a 19” rack mount or NEMA 4X wall mount enclosure.The sensor module contained in the Model 465M uses detectors which have a very narrow band of spectral sensitivity, eliminating the need for UV band pass filters which are subject to deterioration by UV or humidity. Two detectors are used: one for the ozone measurement, and the other to compensate for changes in UV lamp intensity.
-
Unlisted Product
Single / Multi-Channel Process and Safety Ozone Analyzer
Model 465L
-
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NISTtraceable and the included pressure and temperature compensation ensure high accuracy under all conditions.The Model 465L is available in a 19” rack mount or NEMA 4X wall mount enclosure and can be purchased either as a single stream unit or as a multi-channel unit capable of monitoring up to six individual samplestreams. The Model 465L has been designed to deliver excellent performance, high reliability and simple operation. Operating parameters can be easily set up in the field using the operator-friendly menu driven software.
-
Product
Single/Multi-Channel Industrial Safety Ozone Monitor
Model 465L
-
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions.
-
Product
Process Ozone Monitor
Model 465M
-
Teledyne Advanced Pollution Instrumentation
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465M is available in a NEMA 4X wall mount enclosure.
-
Product
Process Ozone Monitor
Model 465H
-
Teledyne Advanced Pollution Instrumentation
The Model 465H is a microprocessor based high concentration ozone monitor for measuring ozone in process gas streams in water treatment, food processing, and research applications. The 465H has been designed to give accurate and stable readings over long time periods with little or no maintenance or calibration. The Model 465H is available in a NEMA 4X wall mount enclosure.
-
Unlisted Product
Compact Ozone Monitor
Model 430
-
Teledyne Advanced Pollution Instrumentation
The Model 430 O3 Monitor is a compact instrument that uses the proven UV-absorption principle. The small footprint and robust design make it ideal for a variety of applications where portability and accuracy are both necessary.
-
Product
Process Ozone Sensor
Model 452
-
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature.
-
Unlisted Product
Process Ozone Monitor
Model 454
-
Teledyne Advanced Pollution Instrumentation
The Model 454 is a microprocessor based gas monitor for measuring mid to high concentrations of ozone in oxygen or air.Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.