Gigahertz-Optik GmbH
Light measurement technology directly from the manufacturer. Gigahertz-Optik GmbH boasts over 30 years of experience in the development, production, calibration, and distribution of optical radiation measuring devices for use in the ultraviolet to near-infrared spectral range. As an independent company, we offer the high flexibility of a medium-sized German manufacturer that can respond to the needs of its customers and markets.
- +49 (0) 8193 93700-0
- +49 (0) 8193 93700-50
- info@gigahertz-optik.de
- An der Kälberweide 12
Tuerkenfeld bei München, D - 82299
Germany
-
Product
Light Meters For Photometry
-
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
Product
Optics And Opto-Mechanics
-
Goniometers, optical rails/benches/stands, lens tubes and light guides.
-
Product
Reflectance Standards
-
Diffuse reflectance calibration standards in white or different grey levels. Traceable calibration for the wavelength range from 250 nm to 2450 nm.
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Opto-Mechanics, Electronics, Software, Accessories
-
A variety of complementary products expand the function of our measuring instruments and support the configuration of complete measuring systems.
-
Product
Integrating Sphere Light Sources
-
Integrating sphere light sources with LED based or continuous broadband emission spectrum for use as luminance standards for camera calibration, for the determination of veiling glare, for the adjustment of night vision devices and much more. Diameters in the range from 50 mm to 500 mm with options like monitor detector, signal output control by manual and remote apertures and much more.
-
Product
Meters For UV-VIS-NIR Radiometry
-
Radiometers for the measurement of UV-visible-NIR irradiance (W/m²) and radiant flux (W).
-
Product
Transimpedance Amplifiers
-
Current-to-Voltage Amplifier for use with Photodiode-Based Detectors. Transimpedance Amplifiers, Standalone Devices with Data Acquisition as well as Display Function (Optometer). Log/Lin Switching Amplifiers, etc.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Light Hazard Meters
-
Light meters to determine the UV radiation (skin and eye), blue light (eye) and infrared (skin) hazards in accordance with international standard.
-
Product
Radiometer
X1-1-RCH-116-4
-
The X1-1 radiometer from Gigahertz-Optik features an RCH-116-4 detector and is ideal for measurement of the irradiance of high power LEDs in the UV-A and blue light range. The device can accurately measure irradiance levels of up to 40,000 mW/cm². One of the outstanding features of the RCH-116-4 detector is its proven concept of a passive radiation absorber coupled to a UV sensor. This provides stability even in high temperature and intense UV radiation environments. In addition to the passive radiation absorber, the device also has a cosine-corrected field of view. The sensor’s housing also serves as a handle. The battery-powered X1-1 optometer supports a usable dynamic range from less than 1 mW/cm² to 40,000 mW/cm² thanks to its high-end signal amplifier. It can be used to perform precise measurements of up to 5 standard LED wavelengths for which the detector was calibrated for active irradiance. In addition to the CW measurement function, the device also has a dose measurement function. The radiometer can be used with other detectors from the RCH series. e.g. for gas discharge lamps. Remote control of the device is possible via its user software and a software development kit is offered for integration of the device in the user’s own software.
-
Product
Uniform Light Sources - Unique And Specialist Configurations
-
We ware experts for custom integrating sphere light sources for specialist applications and for use in demanding environmental conditions. Please contact us with your specific request.
-
Product
Measurement System For Testing & Binning Of Back-End LEDs
TP121-TH
-
The photometric specifications of LEDs must meet very high tolerance requirements regardless of whether they are to be used in general, automotive or other specialist lighting applications. This is often a problem since the manufacturing tolerances of LEDs can be higher than those permitted in the end-use applications. Also, LED binning by LED manufacturers in order to classify LEDs based on their tolerances is performed with flash mode testing using pulsed current flow. However, end-use applications of the LEDs often operate in constant current mode and with significant thermal effects. The sophisticated LED processing industry therefore requires measurement devices that can be used for both manufacturer-compliant pulsed mode, as well as constant current operation mode. When the LEDs are run in constant current mode, the junction temperature has significant influence on the performance and lifetime of the LED. Therefore, test systems should be able to test the LEDs at specific junction temperatures.
-
Product
UV Meters
-
A comprehensive range of UV light meters with optimized solutions for almost every UV application. The following product table lists UV radiometers for measuring UV-A, UV-B and UV-C irradiance (W/m²). In addition to our versatile UVC radiometers, the innovative MDC4 LED UV meter series with centroid wavelength determination offers unique capabilities.
-
Product
Light Meters, Detectors, UV-VIS-NIR Radiometers
-
Devices and systems for photometric, radiometric and colorimetric measurements of light and optical radiation. Light Meters and Radiometers for different applications like UV radiation, Laser measurements, LED measurements, photomedicine and much more.















