Hilkar
Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Air Core Harmonic Filter Reactors
-
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Air Core Shunt Reactors
-
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
Product
Inductive Load Banks
L-Series
-
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
Product
LV Iron Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
Crowbar Resistors
-
Crowbar resistors are three phase resistance banks which are connected to the rotor windings of the DFIG (Doubly-Feed Induction Generator) such as wind power generator. They are used to prevent damage to the inverter circuits attached to rotor side when a fault occurs in the grid. DFIG power converter, which has a restricted over-current limit, needs special attention during faults in the grid. If the rotor current or DC link voltage reaches the threshold value, crowbar resistors disconnect the converter in order to prevent the generator turning into a squirrel cage induction machine. By crowbar resistors, the DFIG could stay connected to the grid and continue its operation.
-
Product
Air Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
LV Iron Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Dynamic Braking Resistors
-
Speed of three phase asynchronous squirrel-cage motors and three phase synchronous motors are generally controlled by motor drives where frequency of the drive output determines the motor speed, and it can be adjusted without dependence on the voltage magnitude.
-
Product
Motor Starting & Control Resistors
-
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
Product
Air Core Electric Arc Furnace Reactors
-
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
Product
dv/dt Filters
-
dV/dT Output Filter Modules effectively protect motors against these high voltage spikes due to the use of motor cables between IGBT based motor drives and motors.
-
Product
Motor Termination Units
-
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
Product
Resistive Load Banks
R Series
-
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.