IET Labs
Manufacturer very high-quality instruments at competitive prices while providing a level of service not often found in the industry.
- (516) 334-5959
- info@ietlabs.com
- 99 Powerhouse Road
#302
Roslyn Heights, New York 11577
United States of America
-
Product
Precision LCR Meter
1693
-
The GenRad 1693 LCR Meter Bridge gives you the best combination of features, in an LCR meter, to meet your most demanding testing requirements. It's a versatile, flexible instrument with a full range of programmable test frequencies, speeds, and voltages. An easy to understand display show both primary and secondary measurement parameters. The Digibridge is an excellent choice for metrology applications requiring accurate and repeatable measurements. The 1693 is also widely used in production testing, incoming inspection, component design and evaluation, process monitoring or dielectric measurement applications.
-
Product
Precision Decade Capacitor
Genrad 1413
-
Six precision decades are employed to provide a range of 0 to 1.11111 F in increments of 1 pF and with an accuracy of 0.05% +0.5pF. Air capacitors are used for the two lower decades and highest grade mechanically stabilized sealed India Ruby mica capacitors are used for the remainder. Air trimmers are used for trimming the two lowest silvered-mica decades. The stability of the 1413 is such that it should not require readjustment with normal service. However, should it become desirable,the four lower decades contain trimmer capacitors that are accessible for this purpose.
-
Product
Decade Capacitor
1419 Series
-
GenRad 1419-A and GenRad 1419-B (Polystyrene) Owing to its very low dielectric absorption, the GenRad 1419A 3 Decade 1000 pF/step & 1419B 4 Decade 100 pF/step Polystyrene Decade Capacitors are particularly useful in research and development work on computer and integrator circuits and on low-level amplifiers. Its constancy of capacitance and dissipation factor as a function of frequency also makes it extremely useful in measuring circuits and as a component in filters and tuned circuits. High insulation resistance and low dielectric absorption make it the 1419 Decade Capacitor a nearly ideal capacitor for dc work.
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Resistance Substitution Box
RS Series
-
The RS Series Resistance Substitution Box is the most commonly used decade box on the market today. The RS Series is not only easier to use, but it is also priced lower than most its competition.
-
Product
Standard Capacitor
1409 Series
-
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
Product
Standard Capacitors
1408 Series
-
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
Product
Digibridge
1659
-
The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the proper range. The result is simple, precise, unambiguous RLC component testing. The GenRad 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). GenRad designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily.
-
Product
Cost Effective Capacitance Decade Box
CS Series
-
The CS Series Capacitance Decade Box is a cost effective and commonly used capacitance decade box for production and educational applications
-
Product
Decade Resistor
esi / Tegam DB62
-
IET has improved the specifications on esi/Tegam's DB62 decade resistor. These Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy of 0.01%, stability, and low zero resistance are important
-
Product
Precision RTD Simulator
RTD Series
-
The RTD Series Precision RTD (Resistance Temperature Detector) Simulator provides a very broad-range of absolute resistance values that replace RTD's and thermocouples. Thermocouples present a resistance that depends on the temperature. The RTD simulator effectively replaces an RTD to test, analyze, and calibrate RTD measuring systems. The RTD Series simulator is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefcient, and power coefcient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors. The special design of the RTD Series provides absolute accuracy, and requires no zero resistance subtraction from any setting Special design of the RTD virtually eliminate zero resistance and switch contact variations, providing the specified absolute accuracy over the entire range.
-
Product
Programmable Capacitance Decade Box
PCS Series
-
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
Product
Resistance & Capacitance Box
RCS Series
-
The RCS-box combines the features and specifications of both the R-box and the C-box in one convenient package. Ideal for setting timers, oscillators, and filters, the resistance and capacitance may be used independently, in series, or in parallel. A shorting link allows them to be coupled or separated.
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.