Self-Adhesive Clips for Liquid/Chemical Sensor Rope
ENVIROMUX-CLP10-LD
-
Use to prevent sensor rope cable from shifting after installation. Self-adhesive backing for easy installation. Material: Nylon. Quantity: 10 clips. Compatible with ENVIROMUX-LDSx-y, ENVIROMUX-CDSx-y, ENVIROMUX-LDx-y and ENVIROMUX-CDx-y.
-
Product
Wind Speed Sensor/Anemometer
ENVIROMUX-WSS
-
Rugged anemometer. 3-cup rotor pressed on a stainless steel shaft. Reed switch and magnet providing one pulse per rotation. Rotor diameter: 5 inches. Speed range: ~ 3 mph to 125+ mph (~5 kph to over 200 kph). Rugged Delrin body with bronze and Rulon bushings. Flat aluminum mounting bracket with 2 holes. esigned to be mounted on top of a pole or bracket. 100 feet of exterior grade wire. Maximum cable length: 1000 ft (305m).
-
Product
Environment Monitoring System
ENVIROMUX-MINI-LXO
-
The ENVIROMUX-MINI-LXO features 2 temperature/humidity ports, 5 digital inputs, and 1 output relay for control of external devices. Linux inside.
-
Product
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
ENVIROMUX-SDS-120V
-
For warning of smoke and invisible fire particles. Ionization smoke detector. Applications from 40°F to 100°F (4°C to 38°C). Front loading battery door. 9V battery backup (included) in case of power failure. One button design for easy testing and HUSH mode activation control. LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode. Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours. Voltage supply: 120VAC. Pre-stripped wiring harness with tinned strands. Audio alarm: 85dB at 10ft. Dimensions: 5" diameter x 1.75" depth. Dust cover prevents false alarms. Tamper resist feature. Links with up to 24 devices. Max distance between first and last device: 1000ft (305m). Alarm memory indicates initiating alarm in interconnected systems. Use compatible relay (ENVIROMUX-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting. ENVIROMUX-RLY-SDS120V includes normally open and normally closed contacts. Contact ratings: 10A at 120VAC, 5A at 30VDC. Regulatory approvals: UL.
-
Product
RS232 Extender via One CAT5e/6 up to 3,935 Feet
ST-C5RS-LC
-
The XTENDEX® RS232 Extender extends one RS232 serial device up to 3,935 feet over a single CAT5e/6/7 cable.
-
Product
Emergency/Panic Button
ENVIROMUX-EBS
-
Sends activation signal when button is pressed. For normally closed or normally open circuit connections. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH: 1.7x2.9x4.6 in (43x74x117 mm). Regulatory approvals: RoHS.
-
Product
Day/Night IP Surveillance Camera
ENVIROMUX-IPCAM-N
-
View and control the camera from the ENVIROMUX web interface, the camera web interface, included software, or with a compatible cell phone. With the ENVIROMUX-2D/5D/16D, a triggered snapshot can be forwarded in alert e-mails. A snapshot can be triggered by any programmed event (motion detection, door open/close, glass break, smoke, liquid detection, etc.). Image sensor: 1/4" progressive scan CMOS sensor. Video Streaming: simultaneous Motion JPEG and MPEG-4. Frame rate: 30fps at 640x480 (VGA) resolution. Lens: F2.0, 4.3 mm (0.17 in), 12 infrared LEDs for night vision. RJ45 connector. Wireless models: wireless IEEE 802.11 b/g up to 54 Mbps. Regulatory approvals: CE, FCC, RoHS.
-
Product
Smoke Detection Sensor - CE Approved
ENVIROMUX-SDS-CE
-
For warning of smoke. Photoelectric smoke detector. Smoke sensitivity: 0.08-0.14 dB/m. Built-in 135° F (57° C) thermal heat sensor. Includes mounting hardware. Connect to RJ45 or digital input sensor ports. Supports CAT5/5e/6 UTP or STP cables. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Operating temperature: 14 to 122°F (-10 to 50°C). Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE, RoHS.
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.