COMET SYSTEM, s.r.o.
Developing and manufacturing computerized measuring devices since 1991. Currently the most of the production contents datalogging measuring systems in several type families, humidity and temperature transmitters and portable thermo-hygro-barometers. Actual production of data loggers is more than 6000 instruments/year. Actual production of temperature and humidity transmitters and transducers is more than 11 000 instruments/year. Company is concentrated especially to the high technological level of its products.
- +420 571 653 990
- info@cometsystem.com
- Bezručova 2901
Rožnov pod Radhoštěm, 756 61
Czechia
-
Product
Compressed Air RH+T+Tdp Sensor
T0211P-2
-
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Relative Humidity Outdoor, Indoor Probe
T1110
-
Only relative humidity output 4-20mA.Also available with direct temperature RTD Pt1000 sensor output.Other sensors on request.
-
Product
Temperature and Humidity Regulator
H3431-2
-
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Three two-state inputs.
-
Product
Thermo-Hygrometer
C3121P-2
-
Thermometer, hygrometer is designed for direct measurement of temperature, relative humidity for compressed air up to 25 bars with 2 meters cable. Audio and optical alarm of measured values. Memory of minimum and maximum measured values. Function Hold - manual storing of actual values for later displaying.
-
Product
Barometric Pressure Transmitter
T2114
-
Barometric pressure transmitter for outdoor and indoor use.Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.
-
Product
Barometric Pressure Transmitter
T2414
-
Barometric pressure transmitter for outdoor and indoor use.Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.
-
Product
Temperature, Humidity, Bar. Pressure Transmitter
T7418
-
For exacting interiors in building energy management and HVAC systems. Are designed for easy installation on ordinary KU68 wiring boxes for household switches and sockets.
-
Product
Temperature and Humidity Probe
T0211-4
-
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Temperature and Humidity Probe
T3313
-
Relative humidity, temperature sensors at 150mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Temperature and Humidity Regulator
H3061-4
-
Relative humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Temperature and Humidity Regulator
H3060
-
Built-in humidity, temperature sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Temperature and Humidity Duct Probe
T0213D
-
Relative humidity, temperature sensors at 150mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Multilogger
M1323
-
The Multilogger is a battery operated datalogger capable of measuring and recording sensor and electrical values through its inputs.
-
Product
CO2 Concentration
H5524
-
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.















