Standard Electric Works Co., Ltd
SEW has established itself to be an industry leader in the design and manufacturing of test and measurement instruments worldwide.
- 886-2-2268-1529
- sales@sew.com.tw
- 5F., No. 105, Zhongcheng Rd.
Tucheng District
New Taipei City, 23674
Taiwan, Province of China
-
Product
Digital 10kV High Voltage Insulation Tester
4310 IN
-
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
Product
Milliohm Meter
4137 mO
-
Standard Electric Works Co., Ltd
● Protection class: IP66 (Lid closed)● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.
-
Product
Cable Phasing Meter
4183 CP
-
Standard Electric Works Co., Ltd
● Safely operates at low voltage ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated.
-
Product
Digital ELCB (RCD) Tester
2712 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
Product
Hot Sticks
HS-120
-
Standard Electric Works Co., Ltd
● Used for the extraction of fuses, isolators & fuse switch disconnections.● Can be attached to the 275 HP Proximity Detectors and contact Capacitive Detectors 21× HVD.● Universal "sunrise" head attachment to fit special tool fittings.● Head Section rated at 100kV per 300mm (5 min).● Comes complete with sunrise fitting and fuse extractor.● 3 × 1.8 meter sticks; 1 × 1.2 meter head section.● Sticks 1 × 1.2 meter head section complete with universal sunrise fitting. ● 1 × carry bag. ● Meets IEC 60855.
-
Product
Digital (1kV up) H.V. Insulation Testers
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
Product
4 Wire Earth Resistance & Resistivity Tester
4236 ER
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.● Optical USB to RS-232 data transmission.● The stored data can be transferred to a PC.● 2 optical LEDs are built-in for data transfer.
-
Product
Current Transformer
ST-30RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 1600~4000
-
Product
Digital AC/DC Clamp Meter (with NCV Detection)
3812 CL
-
Standard Electric Works Co., Ltd
● Full Autoranging for V, A and Ω functions.● Data Hold function freezes reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Auto-zero / REL function.● Non-contact voltage detection.● Auto power off.
-
Product
Circuit Breaker Identifiers
188 FFF
-
Standard Electric Works Co., Ltd
● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then searched(sniffed) by the Receiver to detect the Fuse, Circuit Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type Leds.● The more Leds ON, the stronger the signal.
-
Product
Test Leads
AL-34WB 10A
-
Standard Electric Works Co., Ltd
● Wire length: 1m approx. Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031 CAT IV 300V
-
Product
Safety Voltage Detector
305 SVD
-
Standard Electric Works Co., Ltd
Bright LED visual indication. Audible indication. AC voltage detection: 100Vac ~ 69kVac. Frequency range: 40 ~70Hz. Easy-to-prove method. Self-test function. Power source: 9V alkaline battery. Non-contact detection by proximity. Convenient to use. Operating temperature and humidity: 0°C~40°C / 80% RH Max. Lightweight, robust and compact. Easy access to battery. Comply with EN 61326-1
-
Product
M Series Panel Meters
ST-150T
-
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
M Series Panel Meters
ST-66
-
Standard Electric Works Co., Ltd
● M Series all up to 15A● Case and Composition:Acrylic resin front and ABS resin case. Four studs mounting.● Accuracy:Moving coil type : Class 2.0 Rectifier type : Class 2.0● Color:Black case, white scale plate.● Pointer:Tube type, color in black or red.
-
Product
TEST BOX
6280 TB
-
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1