Showing results: 16 - 29 of 29 items found.
-
ETL-35K -
Kharkovenergopribor Ltd.
ETL-35K system has a multitude of applications in electrical equipment testing and maintenance: testing cable insulation with DC (rectified) voltage up to 60 kV, measuring small leakage current of surge arrestors, high-voltage testing with AC voltage up to 100 kV at industrial frequency, underground utilities tracing, cable fault pre-location and pinpointing, and measuring capacitance and tan delta of various electrical objects at industrial frequency.
-
CBC-50С (CBC-100C) -
Kharkovenergopribor Ltd.
Automatic systems CBC-C-series are designed for high-voltage withstand testing of electrical protective equipment and insulated hand tools. The tests are carried out with AC voltage (CBC-50C: UAC ≤ 50 kVRMS; CBC-100C: UAC ≤ 100 kVRMS) at industrial frequency (f = 50 Hz).
-
UPA-16 (UPA-20) -
Kharkovenergopribor Ltd.
Mobile systems for primary injection testing and trip curve control of circuit breakers and overcurrent protection relays.
-
UPA-1 (UPA-3) -
Kharkovenergopribor Ltd.
These portable systems for primary injection testing of circuit breakers which are used in in AC circuits of industrial frequency.
-
ETL-250 -
Kharkovenergopribor Ltd.
Apart from insulation withstand testing with DC (rectified) voltage up to 60 kV and ability to measure very small leakage currents, the system can be used for testing various objects with small electrical capacitance with AC voltage of up to 250 kV and measuring dielectric dissipation factor (Tan Delta) at industrial frequency.
-
Kharkovenergopribor Ltd.
Operational safety and reliability of electrical equipment and cables directly depend on the dielectric strength of the insulation. Portable and mobile high-voltage testers from KharkovenErgoPribor Ltd. are used for acceptance and operational testing of substation equipment and cable lines, as well as for checking the reliability of personal electrical safety equipment. Our testers range is represented by test systems that allow conducting high-voltage tests with DC and AC voltage, testing polymer insulated cables with very low frequency, testing and locating faults in cable sheath, as well as performing the initial burning of insulation on damaged sections of cable lines.
-
Kharkovenergopribor Ltd.
Power outages can cause serious financial and social damage, as they disrupt the normal operation of security and life support systems, destabilise the operation of industrial facilities, transport network, and utilities. Reliable power distribution is ensured by an effective prevention and prompt elimination of cable faults and electrical equipment failures. KharkovEnergoPribor Ltd. offers a range of integrated solutions designed for testing power cables and electrical substation equipment, as well as locating various types of faults in underground utilities.
-
Kharkovenergopribor Ltd.
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
Kharkovenergopribor Ltd.
The main functions of electrical insulating oils are heat dissipation and reliable insulation of energised parts of electrical installations. During the normal operation, moisture and other impurities penetrate into insulating oils, leading to a deterioration of their dielectric properties. This in turn may result in catastrophic failures of critical electrical equipment.
-
-
-
C-80 -
Kharkovenergopribor Ltd.
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
OLT Series -
Kharkovenergopribor Ltd.
Portable automatic testers of OLT series are designed for dielectric strength testing of insulating oils (mineral and synthetic) with AC voltage up to 100 kVRMS at industrial frequency (f = 50 / 60 Hz).
-
PT-14 -
Kharkovenergopribor Ltd.
The locator PT-14 is used as an induction signal receiver in a cable tracing and fault location set for the following applications:• tracing – finding the route and determining the burial depth of underground cables and other hidden utilities;• fault location – pinpointing interphase and phase-to-sheath short circuits faults;• cable identification – identifying a correct cable from a bunch.