ORTEC
ORTEC is an industry leader in the design and manufacture of ionizing radiation detectors, nuclear instrumentation, analysis software, and integrated systems.
- 865-482-4411
- 865-483-0396
- ortec.info@ametek.com
- 801 South Illinois Avenue
Oak Ridge, TN 37830
United States of America
-
Product
Multichannel Analyzers
-
Multichannel Analyzers (MCAs) are workhorse instruments in many scientific measurements. An MCA analyzes a stream of voltage pulses and sorts them into a histogram, or “spectrum” of number of events, versus pulse-height, which may often relate to energy or time of arrival. The stored spectrum may then be displayed and analyzed.
-
Product
Delays And Gates
-
Delays, Gate and Delay Generators, Logic Modules, and Linear Gates are used in many research or teaching experiments and in non-research applications such as actively shielded spectroscopy systems. Delay modules allow the alignment in time of signals from different paths, so that a logical decision can be made within a logic module which will often result in an electronic go/no-go decision as to whether a particular detector analog output will be processed within an associated multichannel analyzer.
-
Product
Fast Timing Discriminators
-
Fast timing discriminators enable the counting of narrow pulses at very high counting rates, and/or precisely marking the arrival time of these same pulses. They are designed to achieve the best time resolution and the highest counting rates by operating on the fast-rising detector signal.
-
Product
High Purity Germanium (HPGe) Radiation Detectors
-
Semiconductor based photon radiation detectors have been evolving for over half a century, with ORTEC pioneering commercial availability for a majority of that time. Initial offerings were based around lithium-drifted germanium Ge(Li) and lithium-drifted silicon Si(Li). Ge(Li) was later replaced with more advanced, high purity germanium (HPGe) detectors. ORTEC provides a comprehensive suite of HPGe detector solutions covering an extensive range of energies and for a variety of applications.
-
Product
Preamplifiers
-
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
Product
Scintillation Radiation Detectors
-
ORTEC offers a variety of scintillation based radiation detector solutions including Thallium-activated sodium iodide [NaI(Tl)] and Lanthanum Bromide [LaBr3(Ce)].
-
Product
Food Monitoring Systems
-
Is a system of repeated examination, measurement and evaluation of levels of undesirable substances, such as plant protection products, heavy metals and other contaminants, in and on food.
-
Product
Hand-held Radioisotope Identification Device
RadEAGLET
-
Combining a large, high sensitivity crystal with a proven and tested intelligent algorithm, the RADEAGLET can quickly, accurately, and simultaneously detect and identify up to six isotopes, typically in under 30 seconds. The RADEAGLET performs well, even in complex shielded or masked scenarios. ANSI 42.34 compliant, the RADEAGLET offers a user-friendly interface that is intuitive, simple to navigate, provides visually clarity, and utilizes an extensive array of alarms. Supports NaI(Tl) and LaBr3(Ce) to optimize performance across multiple applications.
-
Product
Counters, Timers, And Ratemeters
-
ORTEC offers the broadest range of nuclear counters, timers, rate meters and multichannel scalers. Counters simply count the number of input pulses received during the counting period. Timers count pulses generated by an internal or external clock and are used to measure elapsed time, or to establish the length of the counting period. Rate meters provide a readout of the pulse count rate. Multichannel scalers count the number of events that occur during a specified time interval, referred to as the dwell time, resulting in a time-histogram of counts. “Standalone” and programmable computer controlled versions are available.
-
Product
Radiation Detectors
-
High Purity Germanium (HPGe) DetectorsSilicon Charged Particle DetectorsScintillation DetectorsORTEC is a leading supplier of solid-state, high resolution, semiconductor radiation detectors. These radiation detectors are used in research, commercial industry, environmental protection, health and medical physics, as well as homeland security to detect gamma-rays, X-rays, and charged particles.
-
Product
Nuclear Safeguard Systems
-
Nuclear Safeguards are measures to verify that States comply with their international obligations not to use nuclear materials (plutonium, uranium and thorium) for nuclear explosives purposes. Global recognition of the need for such verification is reflected in the requirements of the Treaty on the Non-Proliferation of Nuclear Weapons (NPT) for the application of safeguards by the International Atomic Energy Agency (IAEA). Also, the Treaty Establishing the European Atomic Energy Community (the Euratom Treaty) includes requirements for the application of safeguards by the European Commission. Organizations such as the IAEA and EURATOM and others are tasked with ensuring declared amounts of material are indeed present in the facilities in which they are stored and that such material is not being diverted to other uses.
-
Product
Digital Current Integrator
-
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure DC currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
Product
Compton Suppression Counting Systems
-
Compton-Suppression Systems are used to reduce the background continuum for low-background counting, thus improving the Minimum Detectable Activity and overall spectrum quality – particularly for small volume samples such as air filters and petri dishes.
-
Product
Gamma Spectroscopy
-
Gamma spectroscopy is the science (or art) of identification and/or quantification of radionuclides by analysis of the gamma-ray energy spectrum produced in a gamma-ray spectrometer.
-
Product
Gross Gamma Screening System
-
The Gross Gamma Screening system is intended for the rapid screening of urine samples for the presence of elevated radioactivity in a post-radiological event scenario. This system allows up to eight urine samples to be counted simultaneously in discretely shielded 3” x 3” NaI Well radiation detectors to quickly identify elevated radioactivity from personnel in the exposed population. This screening process provides critical information to Emergency Response Agencies and is accomplished with minimal operator training.