Neutronics Manufacturing Co.
Our Earth Tester is a very successful replacement of the conventional generator type hand tester. This device is most extensively used to test the earthing installation in numerous power based industries, electrical traction systems and telecommunication networks.
-
HL-200 -
Neutronics Manufacturing Co.
Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 200 is a direct reading tester, and uses a test current of 200A DC, resulting in true value and accurate measurements. Model HL- 200 adopts digital circuit technique and is used for measuring contact resistance of switch control equipment at test current of 200A DC. The measurements are accurate as the test is highly stable. HL- 200 is a new, fully automatic micro controlled tester that measures contact resistance at 200A DC with built in printer.
-
Neutronics Manufacturing Co.
*Display : 75 X 35 min Backlit LCD with Annunciator*Max. Reading : 1999 Counts *Over the limited range indicator : LCD show "1'*Power supply : Six AA batteries to supply the power, OR 2300, 50Hz AC*Lou voltage indicator :The symbol lft appea.*Power consumption : Static Short circuit current : >2mA (250V-1000V), >1mA (2500V)*Work condition : Temperature 0°C - 40°C, relative humidity: 30%-85% RIO*Storage condition : -10°C - 40°C, relative humidity Dimmenslon : 95x148x85mm*Weight : Approx. 850g (induding battenes)*Accessories : Manuai, one pair of test lines, one pair of crocodile clips. six battenes, Mains Adaptor
-
Neutronics Manufacturing Co.
NMC make products are the ideal equipment for HV measuring products are the ideal equipment for HV measuring instruments, apply in power system, electronic equipment factory to test frequency AC high voltage and DC high voltage. This product is composed by HV measuring part and LV display instrument. HV part and LV display instrument are separate when working, it is safe and reliable.
-
Neutronics Manufacturing Co.
This is a portable Relay Testing Set suitable for testing different types like over current, earth leakage relays, circuit breakers of 1A – 50A rating etc. All the components are assembled and enclosed with a portable air cooled M.S.cabinet.
-
Neutronics Manufacturing Co.
Variac Auto Transformers are continuously variable voltage auto transformer, having a movable carbon tip, fixed to a brush-arm sliding on a silver plated commutator. Rotation of the brush-arm by either manual or motor drive, delivers-an output voltage from zero to or above line voltage.
-
Neutronics Manufacturing Co.
The high voltage insulation resistance tester is a handheld instrument designed primarily to measure AC DC voltage. Resistance, Continuity test/Insulation resistance.
-
-
-
-
CBT-Eco -
Neutronics Manufacturing Co.
*Input Supply: 230 V ± 10 %, AC, 50 Hz, 1 Phase (Ground must).*Display: 16 X 2 Big size LCD display with backlight.*Accuracy : Class 0.5*Resolution: 1 milli second*Count: 1 to 9999 milli second*Operation: Accurate Measurement for Close and Trip Command for BreakersThrough Trip-Free Operation C-O-C timing can be measure accurately.Up to 99 No. of Bounces for Close Operation on all three Pole can be count.(Model: CBT CP)Measure timing up to 7 numbers of Bounces on all pole.(Model: CBT CP)Reset for Next Measurement.Indicate the Status of Pole (Close /Open) during start of Test on LCD Display.*Front Panel : Operation Guide Sticker Plate, and Connectors. .(with Printer on Model: CBT CP*)Housing : Aluminum Carrying Case Enclosure.*Accessories : Mains Power Cable, Probe set of 5 MTR long, computer Interface cable for connecting with PC or Laptop and Bag. (Optional), User’s Manual and Test Report.*AVAILABLE MODEL:· Model: CBT CP, with PC Interface and software.· Model: CBT P, without PC Interface and without Software.
-
Neutronics Manufacturing Co.
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
DIT-915: -
Neutronics Manufacturing Co.
• A timer which shows the elapsed time when the test was "ON" and also shows the total time of the test• Displays a voltage warning and sound when AC or DC is present before injecting the test voltage.• A buzz will intermittently sound when high voltage is generated and continues until the circuit is fully discharged• Four voltages (1KV, 2.5KV, 5KV and 10KV)• Auto-ranging and menu-driven.• A bar-graph which displays the voltage decay during the discharge of the tested circuit and the voltage stressing the insulation while the test is in progress
-
Neutronics Manufacturing Co.
NMC offer Fully Automatic Capacitance Tan Delta Test Set with Printer and Computer Interface, Range : 0-12kV, Model : CTD-12.
-
Neutronics Manufacturing Co.
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.