Showing results: 106 - 112 of 112 items found.
-
WFG-120 -
Wuntronic GmbH
The Model WFG-120 System is a complete 3 axis fluxgate magnetometer packaged in a rectangular/parallelpiped package of dimensions 0.75\" x 0.75\" x 2.75\". The package corners are rounded to enable the unit to fit inside a 1.0\" diameter cylinder. The system operates from one of two optional input voltages: regulated ±5 VDC or unregulated ±7 to ±12VDC and consumes a total power of 200 mW.
-
CP387 -
Wuntronic GmbH
The C387 is a single-width, 6U, CompactPCI module with up to 256 digital input/output channels. The C387 base board supports 128 channels of TTL I/O. Four mezzanine card sites can be populated with other forms of digital I/O including isolated input, isolated output, relay output, AC switch output or differential I/O. The mezzanine card concept allows multiple digital I/O types to be configured within a single module to match the application requirements.
-
EON Express / CompuScope 123G2 -
Wuntronic GmbH
The new ultra high-speed, high-resolution Gage digitizers series EON Express CompuScope offers sampling of 3 GS/s at two channels on a single slot PCI Express card and are available with various on-board memory depths from 2 GS to 8 GS
-
ExpressBox 3600-10 -
Wuntronic GmbH
Magma’s ExpressBox 3600 provides optimal server grade GPU and other HPC peripheral expansion to existing host computer systems. Designed to support full Gen 3 x16 PCIe connectivity to all devices, the EB3600 supports 128 Gbps communication between the host and all peripherals. Ten total expansion slots are supported by the EB3600-10 for one or two hosts.
-
Octopus-14 Express / CompuScope Express 8385 -
Wuntronic GmbH
The GaGe Octopus Express 83XX CompuScope PCIe digitizer board features 14-bit resolution with sampling rates up to 125 MS/s with true Effective Number of Bits (ENOB) of 11-bits with 10 MHz input.
-
eXpert Stream-to-Analysis -
Wuntronic GmbH
All Gage PCI Express CompuScopes are able to Stream waveform data through the PCI Express bus directly to PC RAM. By contrast, older Memory Mode operation required storage of data in dedicated digitizer memory prior to data transfer. Streaming provides two distinct advantages over Memory Mode. First, Streaming may overcome the acquisition time limit imposed by the volume of dedicated digitizer memory. Second, in Streaming Mode, the user does not need to await completion of waveform acquisition before accessing the resulting waveform data, which is necessary in Memory Mode.
-
WFG-D-130 -
Wuntronic GmbH
Output 3 axis fluxgate magnetometer to be commercially available. The Digital Fluxgate Magnetometer system can convert and transmit over its serial port (at 38400 baud) all three axes outputs at a rate of 250 samples per second. Slower data rates can also be selected; transmission rate and baud rates are user programmable.