Techimp HQ S.r.L
Strongly committed to innovation and research, Techimp (TECHnological IMProvements) Company stands for excellence in the field of innovative diagnostic technologies applied to electrical engineering.
- +39 051 199 86 050
- +39 051 199 86 099
- sales@techimp.com
- Via Toscana 11/C
Zola Predosa (BO), IT 40069
Italy
-
Product
Complete Network Monitoring
TiSCADA
-
After years of advanced Research, laboratory and on-field tests, Techimp has developed powerful and effective tools which can help asset managers to take critical decisions and manage power plants in a cost saving ways. Ti-SCADA implements a Real Time condition control of your asset, through a powerful Human Machine Interface (HMI) fully configurable, web based, displaying graphs, charts, trends, KPI, historical data, alarms and customizable reports. Ti-SCADA is a fundamental component of the new generation of Techimp on line condition monitoring systems. Ti-SCADA is designed as a Service Oriented Architecture (SOA) based on interoperability standard for industrial automation - OPC-UA - allowing high performance asset management solutions, tailored on customer needs, to be implemented.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
Smart Sensorgrid NG
-
Smart Sensorgrid belongs to the smart sensor family devised for on-line monitoring of diagnostic quantities in electrical assets. It provides traffic-light alerts to SCADA systems / asset and maintenance service. Smart Sensorgrid is a state-of-art PD analyzer, exploiting the TECHIMP T-F Map technology (patented). Such feature allows noise rejection and automatic alarm warning based on amplitude and repetition rate trend relevant to statistical parameters. The PD sensor, a HFCT, is integrated in the smart sensor body.
-
Product
Inductive Sensor
HFCT Ø 30-39-50mm
-
Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.
-
Product
NLFA Notch
-
The NLFA is a multiple element device allowing several useful field configurations. The three internal elements,one low frequency amplifier, two notch amplifier each with the cut off freq. of 50Hz (or 60Hz for a specific version) can be used as independent ones or combined together to increase the notch function. The effect of the cascade of two notches is the increasing of the signal attenuation for the notch frequency.
-
Product
TEM Antenna
-
TEM antenna is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.
-
Product
PD Coupler
-
Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.
-
Product
TD Guard
-
TD Guard Intelligent Sensor is an on-line CONTINUOUS Capacitance and tan-δ monitoring system for transformer bushings. TD Guard Intelligent Sensor is the first and only instrument on the market providing absolute Tan-δ measurement in on-line permanent monitoring of transformer bushings, granting the best level of diagnostic leverage and reliability. Sensitivity better than 10-4.
-
Product
Solution for Industrial Monitoring
PDScope
-
Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Capacitive Divider
-
It can be chosen as PD sensor for Techimp PDCheck, PDScope or PDBaseII systems. It is suitable for on line or off line PD tests onrotating machines, for both spot measurements and monitoring applications. A BNC termination is available to connect the coupler through a coaxial cable.