Techimp HQ S.r.L
Strongly committed to innovation and research, Techimp (TECHnological IMProvements) Company stands for excellence in the field of innovative diagnostic technologies applied to electrical engineering.
- +39 051 199 86 050
- +39 051 199 86 099
- sales@techimp.com
- Via Toscana 11/C
Zola Predosa (BO), IT 40069
Italy
-
Product
Portable PD Acquisition Unit
AQUILA
-
Techimp AQUILA has been expressly designed to respond to all these needs being a robust and compact portable all-in-one PD detection station providing a full range of options ideal for on field applications. It can cope with the toughest outdoor conditions while taking measurements on any electrical asset. 15 years of service experience has been condensed in this unit integrating TECHIMP innovative PD detection technology with multiple connectivity (Wi-Fi, Fiber Optics, USB, Bluetooth) and power supply.
-
Product
Solution for Industrial Monitoring.
PDCheck
-
PDCheck is a compact, stand alone, global diagnostic system for the condition assessment of medium and high voltage electrical systems, based on the detection and analysis of PD
-
Product
Capacitive Divider
-
It can be chosen as PD sensor for Techimp PDCheck, PDScope or PDBaseII systems. It is suitable for on line or off line PD tests onrotating machines, for both spot measurements and monitoring applications. A BNC termination is available to connect the coupler through a coaxial cable.
-
Product
PD Coupler
-
Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Horn Antenna
-
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
Product
Smart Sensorgrid NG
-
Smart Sensorgrid belongs to the smart sensor family devised for on-line monitoring of diagnostic quantities in electrical assets. It provides traffic-light alerts to SCADA systems / asset and maintenance service. Smart Sensorgrid is a state-of-art PD analyzer, exploiting the TECHIMP T-F Map technology (patented). Such feature allows noise rejection and automatic alarm warning based on amplitude and repetition rate trend relevant to statistical parameters. The PD sensor, a HFCT, is integrated in the smart sensor body.
-
Product
NLFA Notch
-
The NLFA is a multiple element device allowing several useful field configurations. The three internal elements,one low frequency amplifier, two notch amplifier each with the cut off freq. of 50Hz (or 60Hz for a specific version) can be used as independent ones or combined together to increase the notch function. The effect of the cascade of two notches is the increasing of the signal attenuation for the notch frequency.
-
Product
PD Calibrator
-
PDCAL has excellent pulse-with stability; scale calibration factors are permanently stored inside its flash memory. Thanks to on board photo coupler PDCAL output pulse can be synchronized with the actual line frequency through external surrounding electrical light source systems.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
PDBase II
-
Even very skilled operators will find hard to make a diagnosis, in situations as the one mentioned above, through a mere visual evaluation of the pattern graph . Techimp new technology bases itself on the principle that efficient separation and identification of PD data can be achieved collecting PD pulses themselves and not only, as digital instrumentation commonly available does, PD pulse peak and phase.











