PINTEK Electronics
PINTEK is now also a leading role aspect of HIGH VOLTAGE INSTRUMENTS manufacturing in TAIWAN. We won this reputation by continuously providing the most innovative and the highest quality products and by providing the excellent after sales service.
- 886-2-86859562~3
- 886-2-86852081
- pintek@pintek.com.tw
- 2F&3F No.32 Tai-Pen Rd
New Taipei City, Shulin 238
Taiwan, Province of China
-
Product
Differential Probe
DP-35
-
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
Product
High Voltage Probe
HVP-40M
-
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
Product
Current Probe
PA-622
-
*Max. ±100A DCA*Resolution: ≧10mA*Bandwidth: DC~300KHz*Rise Time: 1.2 uS*Over Range Function*10mV/A, 100mV/A Range*Adaptor/Battery Input*Separating Design,Convenient Durable
-
Product
High Voltage Probe
CP-3308R
-
*100:1 scope probe *300MHz Bandwidth *Read out Function *Division Ratio x 100 *100MΩ Fix Input Impedance *1500V DC Working Voltage (CAT Ⅱ) *2000V AC peak to peak MAX. (CAT Ⅰ) *CE Approved.
-
Product
DC Power Supply
◎PW-4063R
-
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
Product
High Voltage Probe
HVP-15HF
-
*MAX.VOLTAGE:15KV DC.*BANDWIDTH:DC~50MHz.*DIVISION RATIO:X1000.*SIGNAL/NOISE:>60dB(1KHz)
-
Product
Analog Oscilloscope
PS-1005
-
* 100MHz ALT TRIGGER. * 20MHz LIMIT. * 1mV/DIV SENSITIVITY. * 2nS/DIV RESOLUTION. * DELAY SWEEP * CE, TUV GS, UL, CUL, IEC1010
-
Product
DC Power Supply
PW-3032
-
*Low Ripple & Noise*30V/3A+5V/3A Dual output.*<0.4m Vrms Ripple & Noise(C.V.)*<2.5m Arms Ripple & Noise(C.C.)*Dual Display.
-
Product
Analog Oscilloscope
PS-500
-
*50MHz Vert. Band width*Sweep Time 23 Steps*Dual & Trace, ALT Trigger*Hold-off, X-Y operation*High Vert, Sensitivity : 1mv/DIV*High Sweep Resolution : 10ns/DIV
-
Product
Analog Oscilloscope
CS-406
-
*OSCILLOSCOPE: 40 MHz Dual Trace,Dual Trigger. 1mV Sensitivity. 10ns Resolution. *COUNTER: 5 Digits 0.36" Red LED Display. 0.1Hz~50MHz Auto Range. 0.001Hz Resolution. Auto Gate Time. Auto Detect,Auto Reset. 1mV Sensitivity.
-
Product
Differential Probe
DP-16K Series
-
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
Product
Current Probe
PA-699
-
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
Product
Analog Oscilloscope
PS-355
-
*HOLD-OFF, X-Y OPERATION.*1mV/DIV SENSITIVITY.*10nS/DIV RESOLUTION.*COMPONENT TESTER.*BEAM-FINDER, ILLUMINATE.*WITH DELAY SWEEP.*TWO SWEEP MIX FUNCTION.*CE, TUV GS, UL CUL, IEC1010
-
Product
Current Probe
PA-629
-
*Maximum Current Value: +/- 200ADC, 140A RMS*1mA = 10mA, 100mA (switchable)*Rising Time: 1.2uS*Bandwidth: DC ~ 300kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
Bench Type LCR Meter
LCR-900
-
*Dual LCD Display. *Capacitance, Resistance, Impedance, Inductance, Quality Factor, *Dissipation Factor Phase Angle. *Auto Detect Function. *Open Circuit/Short Circuit Compassion. *Operation Frequency 100Hz to 100KHz. *Basic Accuracy: 0.3% *Measurement Voltage Fixed at 0.6Vrms.