Resolvers
More Info| Narrow Your Results: | Synchro/Resolvers |
|---|---|
| Related Searches: | Encoders, Phase Standards, Servos, Time |
| Expand Your Results: | Instrument Cards, Synchros |
-
73SD2 North Atlantic Industries Contact Info Send To Colleague 2 channels Synchro/Resolver,1 arc-min accuracy, 50 - 10 KHz ...more -
64SD1 North Atlantic Industries Contact Info Send To Colleague Up to 16-Channels Synchro/Resolver, 1 arc-min accuracy with transformer isolation ...more -
5410C-113-1 North Atlantic Industries Contact Info Send To Colleague One Synchro/Resolver Measurement Channel and One Control Transformer Output Channel ...more -
5410C-42 North Atlantic Industries Contact Info Send To Colleague Seven Digital to Synchro/Resolver Channels ...more -
5330 North Atlantic Industries Contact Info Send To Colleague Programmable Synchro/Resolver Simulator. 0.003 degrees accuracy, 47 Hz - 10 KHz and 0.001 degrees resolution. ...more -
5388 North Atlantic Industries Contact Info Send To Colleague One 0.001° Synchro/Resolver Measurement and One 0.001° Synchro/Resolver Stimulus ...more -
5390 North Atlantic Industries Contact Info Send To Colleague One 0.001° Synchro/Resolver Measurement and Two 0.001° Synchro/Resolver Simulators ...more -
5393 North Atlantic Industries Contact Info Send To Colleague One 0.001° Synchro/Resolver Measurement and Three 0.001° Synchro/Resolver Simulators ...more -
4010 North Atlantic Industries Contact Info Send To Colleague Synchro/Resolver or Sine/Cosine to Linear DC Converter. Reverse Polarity and Short Circuit Protected. Commercial or Military Temperature Range ...more -
76CS2 North Atlantic Industries Contact Info Send To Colleague 12 channels of Synchro/Resolver Measurement (Synchro/Resolver to Digital)16 bits, 1 arc-min acc., transformer isolation, self-calibration, background built-in-test and optional on-board refernece. ...more -
5300 North Atlantic Industries Contact Info Send To Colleague Programmable Resolver/Synchro Standard, 2 arc-sec accuracy, 47 Hz - 20 Khz, 0.0001 deg Resolution, Built-in Reference Generator ...more -
540 and 540/20 North Atlantic Industries Contact Info Send To Colleague Synchro/Resolver Bridge ...more -
L1651 North Atlantic Industries Contact Info Send To Colleague Synchro/Resolver-to-Digital Tracking Converter ...more -
A5410C-30-1 North Atlantic Industries Contact Info Send To Colleague One Synchro/Resolver Measurement and Two Synchro/Resolver Simulation Channels ...more -
64DS1 North Atlantic Industries Contact Info Send To Colleague Up to 8-Channels Synchro/Resolver Simulation with 1.2 VA Drive Capability ...more -
77DS1 North Atlantic Industries Contact Info Send To Colleague 8-Channels Synchro/Resolver Simulation with 1.2 VA Drive Capability ...more -
A1663 North Atlantic Industries Contact Info Send To Colleague 19.8 arc-second Synchro/Resolver-to-Digital Converter ...more -
5410C-89 North Atlantic Industries Contact Info Send To Colleague Three Synchro/Resolver Measurement and Three Synchro/Resolver Simulation Channels ...more -
5410C-47 North Atlantic Industries Contact Info Send To Colleague Eight Synchro/Resolver to Digital Channels ...more -
76CS1 North Atlantic Industries Contact Info Send To Colleague Up to 8 channels of Synchro/Resolver Measurement (Synchro/Resolver to Digital) and Up to 6 channels, 1.2 VA Synchro/Resolver Simulation (Digital to Synchro/Resolver) Synchro Outputs ...more -
78CS1 North Atlantic Industries Contact Info Send To Colleague 6U, Up to 8 Synchro/Resolver Measurement channels and Up to 6 Synchro/Resolver Simulation Channels ...more -
73SD1 North Atlantic Industries Contact Info Send To Colleague 4-Channels Synchro/Resolver, 1 arc-min accuracy, 50 - 400 Hz ...more -
Transducers North Atlantic Industries Contact Info Send To Colleague Rugged, resolver-based position transducers provide absolute position feedback. Available in NEMA 1, 4, 12, and 13 configurations. ...more
|
Definition: Use four wires to compute trigonometric values over 360 degrees of rotation by varying the magnetic couplings between its primary (rotor) and secondary (stators) windings. Synchros use three wires. |
Links:
|