Primary Current Injection Test

Sponsor Your Catalog
  • PRIMARY CURRENT INJECTION SETS Protective devices such as relays, overload Coils, Circuit breakers and CTs etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTs, Bimetal Relays, Protection Relays etc.
    R R Enterprises
  • LET-400-RD - Primary Current Injection Test Set The LET-400-RD is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • TEST-901 - Primary Current Injection Test TEST-901 primary current injection test set use ARM chip to control the output process and large capacity of toroidal transformer, and equipped with LCD screen display current meter, also showed primary current value, second current value, turn ratio and the action time. Equipped with aluminum alloy chassis, PC panel, which has the advantages of beautiful appearance, large output capacity, small volume, light weight etc.. It is mainly applied to test CT turn ratio in the power system and the contact resistance etc, which need large current.



    Main Specifications

    1.Power Supply: AC:220V±10%·25A,50Hz/60Hz

    2.Current Output: AC:1000A·5V or 500A·10V, Capacity: 5KVA

    3. The current output waveform distortion: ≤5%

    4.Display,primary current, second current and turn ratio,

    Accuracy: ±0.5%,

    Primary current range: 0~1100A,Resolution: 0.1A;

    Measurement second current range: 0~6A,  Resolution: 0.001A

    Current Duration:

    1000A range: 1000A 2~3minutes,

    500A 3~6minutes

    500A range: 500A 2~3minutes,

    5. Dual protection (overload electronic protection and software protection)

    6.Working environment: temperature -10~40℃, relative humidity≤80%

    7. Volume: 430mm×260mm×260mm

    8. Weight: 28Kg
    Beijing GFUVE Electronics
  • LET-2000-RD - Primary Current Injection Test Set The LET-2000-RD is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • PCITS2000/2 - primary current injection test set The test set has a separate hand-held controller connected by an expandable cable. This allows the operator to work close to a protective relay while controlling a test. The maximum output current is 2000 A a.c. at line frequency. By changing the range switch, half the rated output can be obtained at twice the voltage.
    Megger
  • KAM - Primary Current Injection Test Set This substation testing device is designed to grant high current output when needed in substation commissioning activities.
    ISA Srl
  • Primary Current Injection Test Sets Primary Current Injection Kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, circuit Breaker Contacts etc. RATINGS 500, 1000,1500, 2000, 3000, 4000, 5000 & 10000 A. CONNECTIONS Series-Parallel to select various current ranges. KVA RATINGS 5KVA to 100KVA
    Technology Products
  • LET-2010-RD - Primary Current Injection Test Set The LET-2010-RD is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • LET-4000-RDM - Primary Current Injection Test Set The regulation system is based on a continuously variable motorized autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test
    Eurosmc S.A.
  • LET-1000-RD - Primary Current Injection Test Set The LET-1000-RD is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation. The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load.
    Eurosmc S.A.
  • PCI-600 - Primary Current Injection Source The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers. The PCI-600 is versatile and can also be used in many other applications that require a high-current source.
    Vanguard Instruments
  • LET-400-RDC - Primary Current Injection Test Set The LET-400-RDC is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation
    Eurosmc S.A.
  • PT Series - Primary Current Injection Test Set The PT Series has been designed specifically for primary injection testing of circuit breakers, protective relay equipment & other applications that require high variable currents.
    AGM Power Engineering
  • LET-2000-RDM - Primary Current Injection Test Set The LET-2000-RDM is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • DDG Series - Primary Current Injection Test Set High current generator is essential equipment used for electrical debugging to generate high current, which be widely used in power plants, power distribution stations, electrical plants , scientific research, laboratories and other units. It is a short-term or intermittent work device and characterized by small size, light weight, good performance, easy use and maintenance.
    Wuhan Huatian Electric
  • ODEN A - Primary current injection test system A powerful test system designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the transformation ratio of current transformers and for other applications that require high variable currents. Up to 8 kA can be generated.
    Megger
  • LET-4000-RD - Primary Current Injection Test Set The LET-4000-RD is designed to perform most of the primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • TEST-902 - Primary Current Injection Test Set TEST-902 primary current injection test set use ARM chip to control the output process and large capacity of toroidal transformer, and equipped with LCD screen display current meter, also showed primary current value, second current value, turn ratio and the action time. Equipped with aluminum alloy chassis, PC panel, which has the advantages of beautiful appearance, large output capacity, small volume, light weight etc.. It is mainly applied to test CT turn ratio in the power system and the contact resistance etc, which need large current.

    Main Specifications

    1. Power Supply:AC:220V±10%·50A, 50Hz/60Hz

    2. Current Output:AC:2000A·6V or 1000A·12V, Capacity: 12KVA

    3. Display,primary current, second current, turn ratio;

    Primary current range:0~2200A,Resolution:0.1A, Accuracy: ±0.5%;

    Measurement second current range:0~6A, Resolution:0.001A,Accuracy: ±0.5%

    4. Current Duration:

    2000A range: 2000A 2~3minutes,

    1000A 3~6minutes

    1000A range: 1000A 2~3minutes,



    5. The current output waveform distortion: ≤5%

    6.Working environment: temperature -10~40℃, relative humidity≤80%

    7.Volume:360 mm× 300mm× 295 mm

    8.Weight:host 35Kg,External voltage regulator weight 15Kg
    Beijing GFUVE Electronics
  • LET-400 - Primary Current Injection Test Set The LET-400 is designed to perform primary tests that are necessary in substations commissioning. It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
    Eurosmc S.A.
  • ODEN AT - Primary current injection test system This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.
    Megger
  • AK23 - AK43 - AK63 - INJECTION TEST SETS Three phase primary current injection. Testing of protection relays. Thermal and magnetic device testing. Temperature rise test and trip test of circuit breakers and junction points
    Hilkar
  • T 3000 - Substation Maintenance and Commissioning Test Equipment This primary current injection testing system is designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers.
    ISA Srl
  • TM200 - Digital Timer A timer is often needed for use with the CSU600A current supply unit or ODEN A primary current injection test system. Testing relays with SVERKER 650 also requires an extra timer if more than one timing cycle is to be measured. Timer TM200 is ideal for these tasks thanks to its precise accuracy, its broad application range and its compact dimensions. Timer TM200 is the obvious choice for maintenance work in substations.
    Megger
  • Primary Injection Relay Test Equipment The Primary Injection range is made up of various types of high current injection equipment to meet most application requirements. This range of equipment is designed for field use and is extremely rugged and robust. 
    Eurosmc S.A.

Results 1 - 24 of 27