Filter Results By:

Products

Applications

Manufacturers

Showing results: 8266 - 8280 of 8452 items found.

  • X-Ray Fluorescence Analyzer

    MESA-50 - HORIBA, Ltd.

    HORIBA has been selling the XGT-WR series of EDXRF analyzers for many years, providing screening measurements of samples containing hazardous elements such as Pb, Cd, Hg, Cr, Br, Sb, As for RoHS, ELV, and Cl for halogen free applications.XGT systems are used daily throughout the world. HORIBA has now developed the new MESA-50 EDXRF analyzer, based on its long experience with customer requirements and knowledge. MESA-50 provides user friendly operation and good performance. MESA-50 includes three analysis diameters, suitable for every sample, from thin cables and electronic parts to bulk samples. The combination of SDD detector and Digital pulse processor(DPP) changes the image of EDXRF.HORIBA's new MESA-50 supports ecological procurement; it contributes not only to EU RoHS and ELV compliance testing, but also regulatory work for many other countries.

  • Debug Fixture

    IST Engineering, INC.

    With at-speed test, debug can easily become a problem: If test points are on the bottom, as is often the case for test processing, then this requires the board to be flip over for the debug. However, during at-speed testing, key devices and signal paths are often on the topside. IST Engineering has in-house expertise with debug fixtures, which allow the test technician to flip over a test board, or even hold it vertically for dual-sided access, while still running the Device-Under-Test at full-speed through card-edge connectors - whether these are standard DIN type or F or N type co-ax connectors. The debug stations are constructed robustly, with metal frames and high-grade flexible cabling and can also be used as backup test stations in a manufacturing flow. They can be built with custom machined waveguide connections for RF/Microwave applications, or with standard, off the shelf connectors, as defined by the application. A number of these debug fixtures are in production use with a range of customers.

  • WiFi Traffic Generators

    LANforge WiFIRE - Candela Technologies Inc.

    wireless traffic generator is an excellent choice for testing Access Points and other WiFinetworks. The CT520 uses a modified Wireless driver for WiFi NICs based on the Atheros chipset. It cansupport up to 32 Virtual Stations. Each of the Virtual Stations has its own IP address, IP port space, MACaddress and routing table. The Virtual Stations can be assigned to communicate to a particular AccessPoint, use a particular SSID, and have a WEP (64 or 128bit) or WPA/WPA2 key assigned. More advanced802.1X authentication is also included. There is a single WiFi radio per CT520 but multiple LANforgesystems can be clustered together for more realistic radio interference patterns and increased trafficgeneration capability. The radio supports 802.11 a, b, g or n mode. Transmit power andchannel/frequency is configured on a per-radio basis. Most other settings are configurable per virtualstation

  • Axial Clip-On Extensionmeters for Cable

    Instron

    Rugged design extensometer for axial tensile testing of stranded wire requiring a long gage length device and the ability to measure axial elongation accurately on a specimen that twists when pulled. This design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. Meets existing ASTM class B-2 and ISO 9513, class 0,5 requirements for accuracyDuring operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. The units have hardened tool steel knife edges that are easily replaced. Quick attach kit (included) allows easy one hand mounting on specimen. Removal of the extensometer from the specimen prior to fracture, to avoid damage to the instrument, is strongly recommended.Type of Loading: static tension Specimen Material: alloy steel Specimen Types: stranded cable

  • Safety Compliance Test System

    EN 60601 - LXinstruments GmbH

    Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.

  • Regenerative Grid Simulator

    61800 - Chroma Systems Solutions, Inc.

    Power rating: Up to 300kVA, single or three phase outputOutput Voltage: 0~330V L-N / 0~570V L-L0~400V L-N / 0~692V L-L opt. without using a transformerOutput Frequency: DC, 30Hz~100HzMaximum power delivered down to 200VAC L-NFull 4 quadrant, fully regenerative up to 100% of output current ratingSpecifically designed for PV inverter, Smart Grid and EV related test applicationsProgrammable slew rate settings for voltage and frequencyProgrammable voltage and current limitsTurn on, turn off phase angle controlLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetParallel output for higher power applications (three phase only)

  • Bench Multimeters

    TM-8155+ - Twintex Electronics Co., Ltd

    ★ Large LCD, 80000 count Dual-display, Analog bar 21 sets.★ 50 measuring functions, with basic DCV, ACV, DCA, ACA, Ω, CAP, Hz, TEMP, diode and Continuity measuring function, etc.★ 18 types of frequency, frequency up to 8MHz, 1800 waveform outputs, 1%~99% duty cycle★ Simultaneous measure (AC+DC), (AC+Hz), (DC+dBm), (dBm+Hz), (Hz+Duty), (℃+℉)★ Auto data update and refresh, auto data hold, auto peak hold.★ 36-hour dynamic record: MAG, MIN, AVG, MAX-MIN (RELΔ), (REL%), setting upper & lower limit, timing measurement★ AC measuring adopts highly accurate true RMS measurement, with testing frequency bandwidth and AC+DC measuring★ RS-232 interface

  • 2-port Battery Portable Passive Intermodulation Analyzer - iXA Series

    iXA - Kaelus

    The Kaelus iXA Series Passive Intermodulation (PIM) analyzer is a dual-port, battery powered PIM Test Analyzer. It supports multiple test scenarios such as testing at the top of the tower, the base of the tower, rooftop, in-building for DAS systems and external PIM Finding.No other PIM tester has ever been integrated to this level! The iXA includes a network of electronic switches to change from one-port to two-port measurement seamlessly. In addition, with integrated Range-to-Fault (RTF) on each port, the user can first troubleshoot the system for internal PIM. Then, without reconnection, the user can progress with the external PIM process, making the entire process much more efficient.With integrated RTF on each port, the user can collect four times more range-to-fault data than the standard 1-port PIM Finder solution. Thus, the user can easily locate and swiftly eliminate the strongest PIM source.

  • SNR Noise Generator

    CNG-EbNo - Noisecom

    The CNG-EbNo is a fully automated precision signal to noise (AWGN) generator that sets, and maintains a highly accurate ratio between a user supplied carrier and internally generated noise, over a wide range of signal power levels and frequencies. The internal AWGN meter provides repeatable SNR waveforms for accurate signal generation. The instrument gives system, design, and test engineers in the telecommunications industry a single tool to generate precision signal to noise ratios. These signals are used to compare theoretical BER to SNR ratios, found in "waterfall" type graphs, with measured values from the DUT to evaluate different modulation schemes. Users can obtain higher yield through automated testing, plus increased confidence from repeatable, accurate test results. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.

  • Walk-In Xenon Lamp Weathering Test Chamber

    ACMAS Technologies Pvt. Ltd.

    Xenon is one of the noble gases and is a major component of arc lamps and flash lamp and it also has its importance in general anesthetics. One of the major applications of xenon lamp is that it can be used in research applications to simulate the sunlight.Weiber walk in xenon lamp chamber uses xenon lamp to simulate the whole sunlight spectrum that can produce many destructive effects on the products. This simulation environment provided in the chamber is used to test the resistance of various manufactured products towards these destructive conditions. This chamber is used for quality control, product development and scientific researches and many more. With a variety of models and options, you can customize your chamber to fit your testing needs. With walk in option you have a facility to test your product in bulk quantity and even for the products which are larger in size. This chamber also known as Uv Test Chamber and Xenon Lamp Weather Resistance Test Chamber.

  • Extremely Accelerated Stress Test Chambers

    ACMAS Technologies Pvt. Ltd.

    The extremely accelerated stress environment is defined by high temperature, high humidity and high pressure. WEIBER provides humidity resistance evaluation test for electronics components through customized Extremely Accelerated Stress Test Chamber. This chamber provides high performance test in minimal amount of time according to international IEC 60068-2-66 standard. This chamber also known as Accelerated Stress Test Chamber, Halt and Hass Test Chamber, Halt Test Chamber and Hass Test Chamber.This chamber reduces the time taken for humidity testing in electronic components. 2 types of tests saturated and unsaturated extremely accelerated stress test can be performed. In saturated test the temperature is maintained at 1210C at 100%RH, and for unsaturated temperature of 110, 120, 1300C is maintained at 85%RH. Normally for electronic components unsaturated type test is done.

  • Battery Extra Load Units

    IBEKO Power AB

    Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.

  • Double Function Tester with Shielded HF Test Chambers

    End-of-line Tester UTP 9010 RF - NOFFZ Computer Technik GmbH

    The UTP Series 9010 is a scalable test series available in a variety of feature-rich variants and many designs. The UTP 9010 RF function tester shown here as an example is suitable for tests with a medium number of channels and complexity. It is designed for parallel testing of two or more test items. The measuring instruments used are used alternately for several test items. Due to its compact design and construction as a modular system, this powerful tester can easily be expanded to larger numbers of channels.The integrated HF test chamber UTP 5070 developed by NOFFZ allows an independent shielded test. It can be operated manually or fully automatically by a robot .The basic version of the UTP 9010 series is an ideal system for functional and end-of-line tests and is already preconfigured for this purpose. The RF tester presented in the example is used in particular to test infotainment and eCall modules in the vehicle as well as IoT products with wireless technologies.

  • UltraFast Gas Chromatograph

    Falcon - Teledyne Monitor Labs

    The Teledyne-Falcon Gas Chromatograph (CalidusTM) is now manufactured and fully supported by Teledyne which acquired assets of Falcon Analytical Systems & Technologies, LLC in October 2018. Along with Falcon assets, most employees now work for Teledyne, so the transition has been seamless and highly successful. To find sales and support, go to: Worldwide Sales Representatives.The Teledyne Falcon Gas Chromatograph is a fast and superior analyzer perfect for process sampling and field testing to verify consistency of materials and processes. Fence line or exhaust Benzene or VOC monitoring can be performed continuously or on an intermittent (portable) basis. The Teledyne Falcon GC paired with an FID detector will speciate hydrocarbons in a fuel sample for determining fuel quality and heating value. The simplified modular design means that a technician can swap a column or detector and perform maintenance quickly and with minimal training.

  • AC Power Source

    9420 - NH Research, Inc.

    AC Source with HiVAR Technology Ideal for ATE use in Aviation, Aerospace, Defense, Military/Mission Critical Testing, Manufacturing Test, Research & Development & More! The Model 9420 AC Power Source redefines selection of an AC Source by addressing how to compensate for reactive power from capacitive or inductive elements in the load. Often overlooked when sizing a source, reactive power negates some portion of nominal VA power in order to arrive at true power (Watts) that does the real work. Traditional AC sources list only their VA rating leaving it up to the user to figure out how much true power remains after reactive power reductions. In many cases that reduction is substantial and then requires selecting a much larger VA-rated source than originally anticipated. The increased cost and size penalties are often considerable.

Get Help