Showing results: 8101 - 8115 of 8448 items found.

  • Ceramics and Glass Inspection Systems

    Intego GmbH

    Due to their special material properties, ceramic and glass components are the basis of many high-tech products. The same properties make the production complex and costly. Substrate defects that lead to failure of finished components should be avoided at all costs. For this reason, early automated optical inspection is essential.For the inspection of sapphire and quartz glass Intego has developed systems to detect both external and internal defects and can also provide cutting suggestions. Using index matching it is possible to test rough or uneven glass profiles.For the inspection of ceramic components Intego offers solutions specifically tailored to the respective testing task. Our modular design uses standard components that have already been developed and tested and in most cases only requires minimal adaptation.

  • DC Vibration Unit Tester

    BK2116 - BaKo Co., Ltd

    As the technology for BLDC motors advances, more advanced testing is also needed. The BK2116 DC Vibration Motor Tester was designed when of several of our clients needed to test the new generation of 3 port DC vibration motors. Using the BK2116, you can test the electrical specifications (RPM, current, drop pulse, and start up voltage) and also vibration level, and noise of motors with either 2 or 3 ports. The BK2116 can concurrently test 2 DUT's and BaKo's Test Shop software makes it very easy to set up and test. And because you use it with a PC or notebook, you can see graphs of the data as you test, and also save it to analyze later, or to analyze the data you gather over time.

  • Edge Press Technology Bed of Nails Testers

    Protector Edge Press Family - Test Electronics

    Designed for testing heavy massive boards. Boards with heavy components like large transformers and inductors can destroy normal test fixtures. This design utilizes a 3 plate system where an internal lever actuated sub plate containing the test pins raises to probe the circuit board when the handle is pulled. Heavy boards can bend and break exposed test pins. Similarly large boards which need to be probed by very small delicate test pins can also benefit from this protected test fixture design. This fixture is recommended in situations where there is a high board mass to pin size ratio and pin protection is required. Front and rear panel modular inserts allow for easy updates and customizations to the user hardware interface.

  • Electrical Safety Testers

    STW-9900 Series - Texio Technology Corp.

    * 500VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* Zero Crossing Turn-on Operation* Zero Crossing Turn-on Operation* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)

  • Optical Path Converter

    LS512A/LS512B - Lisun Electronics Inc.

    There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again. It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.

  • 4 Channel 1.0 ~ 17.0 Gb/s Pulse Pattern Generator and Error Detector

    CA9806 - UC Instruments, Corp.

    The UC INSTRUEMNTS CA9806 is a high performance, flexible four channel Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (consult factory for higher or lower operation speeds). It is also a standalone Bit Error Rate test solution that incorporates an internal full rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build‐in 8.5 ~ 15 Gb/s eye diagram testing function.

  • Diagnostic Set

    OMK-SR-OTS.2 - OPTOKON a.s.

    Diagnostic set includes measuring instruments and tools for diagnosing faults on fiber optic cables with connectors STRATOS and CTOS, and direct technical successors connectors HMA. The OPTOKON Diagnostic Set includes two instruments - Light source and Power meter. Both instruments are housed in a hard carry case that meets the requirement of fiber optic networks installation and maintenance teams, who require rugged and lightweight fiber optic test equipment that combines high performance with ease of use and reliable operation. The Diagnostic Set allows traceable measurements on dual wavelength and data storage to the PC. It includes the hybrid master HMA-FC patchcord for testing of harsh environmental networks and is comprised of these measurement instruments: LS-800 light source and PM-800 power meter

  • Line Monitor

    LE-170SA - LINEEYE Co., Ltd.

    LE-170SA is a compact hand-held size line monitor for CAN/LIN. It has a touch screen and can be control as for smartfones. It has 1 CAN channel and 1 LIN channel and it can monitor both CAN and LIN communication thus monitoring of the network which has both CAN and LIN is available. The monitor function can diplay the communication data in real-time while saving it. The simulation function can send/receive the test data instead of the original communication partner. The ID filtering and trigger function make your development/evaluation more efficient. It also can measure 4 external signals as degital signals or analog signals while monitoring the communication data.It is light (300g) and convenient for field testing. The line monitor is useful for not only development but also maintenance.

  • PXI 1A Fault Insertion Switch 22-Channel

    40-195-001 - Pickering Interfaces Ltd.

    The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.

  • PXI 1A Fault Insertion Switch 11-Channel

    40-195-101 - Pickering Interfaces Ltd.

    The 40-195 is a 22 Channel Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions on pairs of signals between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Relays in-line with the signal paths allow open circuit conditions to be simulated on either side or both sides of a signal pair. Relays between each channel pair enable adjacent signals to be shorted, and relays between signal paths and the "Fault" connection allow the application of external user applied fault conditions.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • GAOTek Portable H/L Voltage Clamp Current Leaker

    GT00YA00ZX - GAO Tek Inc.

    The GAOTek Portable H/L Voltage Clamp Current Leaker measures high voltage current with a 12.5 in (32 cm) insulating rod, adopting the latest CT technology and integrating mask digital technology. This instrument provides high precision, reliability, and stability with its integrated design between transducer clamp and domain. This leaker can be used to measure any wire with or without the insulation layer where the voltage is below 10 kV. The insulating rod is portable, moisture resistant, heat resistant, shock resistant, and insulating. It provides additional functionalities such as online current testing, peak and data holding, data storage, detection of high and low current in primary and secondary circuits separately, and provision of suitable calculations to conclude change in high and low pressure.

  • Life Cycle & Fatigue Testers

    Banair

    Switches can use all these operations. Membrane switches, keyboards and keypads will all require a push with a known force. On/Off switches will combine a push and a pull or possibly push on, push off. A rocker switch and toggle switches will require a push in two different places. Rotary switches (and volume controls, potentiometers) need to be rotated clockwise and counter clockwise The standard life cycle and fatigue tester the B886 Simon System has been designed for life cycle and fatigue testing of switches, membrane switches, keyboards and keypads. It contains all the components needed to life and fatigue test a products that need to be pushed. We can also supply different actuators for a push, pull, rocker, toggle, volume control or rotary switch.

  • High Voltage Switching Test System

    Accel-RF Corporation

    The advanced development of new technologies, such as SiC and GaN, have opened the opportunity for more efficient and higher voltage/power performance in switching and power management circuits. Their high cutoff frequencies, low on-state resistance, and very high breakdown voltages can increase power supply power handling densities approaching hundreds of watts/inch. Reliability of these new technologies and techniques is critical for realizing practical applications. While Silicon devices have a rich history of proven reliability, these newer compound semiconductor technologies are too new to have a reliability history and have not been well proven. Further, process variations, even in well-controlled lines, yield widely varying results. This has driven the need for additional testing and to burn-in devices prior to delivery.

  • Multitype ICP Emission Spectrometers

    ICPE-9800 Series - Shimadzu Corp.

    Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.