Filter Results By:

Products

Applications

Manufacturers

Wave

undulation up-down synced with to and fro. Scope of site

See Also: Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Millimeter Wave, Shock wave, Ocean, Quantum, Gravity, Particle


Showing results: 601 - 615 of 829 items found.

  • Process & Lab FTIR FT-NIR Analyzers

    Process Insights, Inc.

    Using a broad spectral region from the near-infrared to the mid-infrared, our Guided Wave ANALECT® Series of FTIR/FT-NIR analyzers measure physical and chemical properties of liquids, solids and gases. They are ideal for complex refinery applications such as fuels blending and component streams applications for polymers, petrochemicals, chemicals, pharmaceuticals in addition to general manufacturing. Customers include ADNOC, BP, CITGO, CPCL, Gazpromneft, HPCL, IOCL, Orpic, Phillips 66, Rompetrol, Statoil, PBF Energy and Tesoro.

  • Resistive Components

    Smiths Interconnect

    Diamond is the best thermal conductor on earth. Combined with a low dielectric constant, it is an excellent RF dielectric material for high-frequency applications in which thermal performance is equally critical. By applying cutting-edge thin film process and extensive millimeter wave design experience, Smiths Interconnect has created a high-performance line of resistive components. The resulting products, our Diamond RF Resistives® resistors, terminations, and attenuators, are significantly reduced in size and unparalleled in average and peak power handling.

  • Vane Anemometer

    AM-4836V - Rinch Industrial Co.,Limited

    Parameters measured: Wind speed, Flow, Beaufort Scale, Wave, Temp., wind directionRange:Wind speed: 0.4-30.0m/s1.4-108.0km/h80-5910ft/min0.8-59.3 knotsFlow: 0.004-9999 m³/min0.013-9999 ft³/minB. Scale: 0-12 forceWave: 0-14mDirection indicator: 16 ways (the resolution is 22.5º)Temp. : 0-60℃ / 32-140℉Accuracy: ±2%n+2Resolution: 0.1/1PC interface: RS232C (Cable & software are optional)Can memorize 50 group dataAuto power offPower supply: 4x1.5V AA A (UM-4) batteryBattery indicator: low battery indicatorDimensions: 156x67x28mm

  • PXI 4x4 20GHz Matrix with Termination

    40-787-528-4X4-T - Pickering Interfaces Ltd.

    The 40-787 Microwave BRIC platform is designed to provide a solution for complex RF matrix applications. Using a common mechanical platform the module can be constructed to provide scalable non-blocking or blocking microwave matrix for frequencies to at least 20GHz. The standard configurations provide up to a 4x4 matrix. More complex matrix can be constructed by adding further switching functions and other devices inside the module. The matrix is available with optional terminated inputs to avoid the creation of standing waves on unconnected input cables.

  • HV Testing Transformer

    Wuhan Sangao Electrical Test Installations Limit Co.

    Inflatable Ultralight Non Partial Discharge Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The high-light characteristic of the equipment reflects the smallness in size, lighter in weight clean, oil-free, unnecessary static of field investigation, longer working life without maintenance and slightness in non-partial-discharge. It is used for the insulators' voltage-resistance testing.Major technical characteristicVoltage unit50.100.150.200.250.300.500kVCapacity unit3.5.10.15.20.25.30.50.100.150.200.300.500.1000kVAInput voltage220, 380V uniphase 50HzImpedance voltage6%≤No-load current8%≤Wave form distortion3%≤Annual gas leakage1%≤

  • Analyzers & Systems

    Guided Wave

    The optical or spectrum analyzer is the brain which transforms the signal collected by the sample interface into actionable information. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV-Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal light transmission for long-term reliable measurements. More information is available about specific analyzers on each product page or on the process analyzer product overview.

  • Variable Reluctance Absolute Pressure Sensor

    AP10 - Validyne Engineering

    The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.

  • Power Frequency Transducer

    PP1S - Hsiang Cheng Electric Corp

    1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540

  • Pressure Sensor Kit for Changing Ranges

    DP15TL - Validyne Engineering

    The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.

  • EasyView™ Indoor Air Quality Meter/Datalogger

    Extech EA80 - Extech Instruments Corporation

    The EA80 checks for Carbon Dioxide concentrations using a maintenance-free dual wave NDIR (non-dispersive infrared) CO2 sensor with a range of 0 to 6,000 PPM. It can automatically data log up to 20,000 data sets or you can manually enter up to 99 sets for later recall. Additional features include: auto power off, data hold, max/min with time stamp and alarm. Comes complete with six AAA batteries, Windows 95/98/NT/2000/ME/XP compatible software and an RS-232 interface cable.

  • Magic Tee

    MHTXE - Elmika

    The MHTXE Magic Tee Hybrid Couplers for millimeter waves are matched power dividers for variety of applications (general purpose power splitters, power combiners, phase measurement circuits, phase / frequency discriminators). The MHTXE Magic Tee Hybrid Couplers are available in waveguide bands between 33 and 170 GHz. These couplers are four-port transmission line components with a port configuration as shown in figure. Operation bandwidth is limited to 20÷90% waveguide operation frequency range depending on performance specifications.

  • Radar・Sensor Simulation Framework

    COSMOsim - OTSL Inc.

    Millimeter Wave Radar simulator and LIDAR (Laser Imaging Detection And Ranging) simulator for Automotive sensor simulations, and also can provide 3DCG MAP for specific radar which has millimeter accuracy. Now we can only provide AMMWR and ALR to the following COSMOsim Framework. This simulator enables automotive manufacturers to simulate a driving situation by sensor-based modelling, check the recognition and control of autonomous driving, and verify the sensor-mounting positions on vehicles efficiently, which eliminates the need for test driving with real vehicles.

  • Waveguide Cassette

    Elmika

    Waveguide cassettes provide easy way for the network analyzer calibration and material properties as dielectric permittivity or (and) magnetic permeability measurements. By changing insertion sections, it is possible to calibrate "Short" and "Thru". Optional cassettes with quarter wave "short" inserters are available. Using this waveguide cassette, it is possible to do vector network analyzer calibration or additional scalar network analyzer calibration. Insertable sample holders supports two measurement methods: the rod in the centre of the waveguide and filled waveguide cross-section.

  • Motor Termination Units

    Hilkar

    Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.

  • Short-wave Infrared Camera

    Goldeye CL-008 Cool - Allied Vision Technologies

    The Goldeye CL-008 is one of the fastest QVGA resolution short wave infrared (SWIR) cameras with Camera Link interface. With frame rates up to 344 fps at full resolution, versatile application fields can be addressed and processes can be sped up strongly. To enable low-noise imaging in the spectral range from 900 nm to 1700 nm, the camera is equipped with a nitrogen filled cooling chamber. It enables the thermo-electric cooler (TEC) to operate the sensor at a temperature of 5o C and avoids condensation.

Get Help