Filter Results By:

Products

Applications

Manufacturers

Wave

undulation up-down synced with to and fro. Scope of site

See Also: Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Millimeter Wave, Shock wave, Ocean, Quantum, Gravity, Particle


Showing results: 601 - 615 of 838 items found.

  • Ultra High Performance Multi-Sensor Camera System

    FLIR M500 - Teledyne FLIR

    The gyro-stabilized FLIR M500 cooled thermal camera is our most technologically-advanced M-Series pan and tilt camera ever. Designed around a cryogenically-cooled 640 x 512 pixel Mid Wave Infrared (MWIR) thermal sensor, the FLIR M500 excels at both short and ultra-long range target detection and identification. It features a 14X continuous optical thermal zoom, a color HD camera with 30x zoom, an LED spot-beam, video tracking and radar integration.

  • AC Power Supplies

    BLC Series - Behlman Electronics Inc.

    The BLC Series delivers all the quality features our customers have come to expect from Behlman; clean sine wave output with excellent line and load regulation, high efficiency and low harmonic distortion. A multi-pulse input transformer offers low-input harmonic distortion and high power factor as required by European standards. Unique protection circuitry provides for over-temperature protection; short-circuit protection and voltage fold-back during overloads to maintain undistorted waveforms.

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Signal Generator

    MAG-2015AD - MCH Instruments Co.,Ltd.

    Feature:*Signal frequency: 0.1Hz~15MHz, continued*Wave form: square,sine*Output attenuator: 0dB,20dB,40dB,60dB*Output level: 20Vp-p in open ciruit,not less than 10Vp-p with 50Ω load*Rising edge of Square not more than 35ns at 2MHz*Sine distortion less than 1%,amplitude-frequency characteristic ±0.5dB with in 2MHz, ±3dB above 10MHz*Frequency Counter: 20Hz~30MHz*Power supply: AC 220v (110v optional)

  • Ultrasound Measurements

    ECO-TECH

    Is sound waves with frequencies higher than the upper audible limit of human hearing. Ultrasound is no different from 'normal' (audible) sound in its physical properties, except in that humans cannot hear it. Ultrasound devices operate with frequencies from 20 kHz up to several gigahertz.Ultrasonic devices are used to detect objects and measure distances. Ultrasound imaging or sonography is often used in medicine. In the nondestructive testing of products and structures, ultrasound is used to detect invisible flaws.

  • Databus-to-Network Interfaces

    OBB2 - Astronics Corporation

    The OBB2 is highly configurable and includes built-in standard peripherals (Ethernet, serial, and USB), along with four internal Cores that can be populated with a variety of databus protocols and discrete I/O modules. With the newest advanced set of MIL-STD-1553 and ARINC 429 modules, users can verify wave form compatibilities, test functions of bus shorts and opens, and—when combined with our CoPilot® software—perform lab, production and flight test verification and simulation right out of the box.

  • Process & Lab FTIR FT-NIR Analyzers

    Process Insights, Inc.

    Using a broad spectral region from the near-infrared to the mid-infrared, our Guided Wave ANALECT® Series of FTIR/FT-NIR analyzers measure physical and chemical properties of liquids, solids and gases. They are ideal for complex refinery applications such as fuels blending and component streams applications for polymers, petrochemicals, chemicals, pharmaceuticals in addition to general manufacturing. Customers include ADNOC, BP, CITGO, CPCL, Gazpromneft, HPCL, IOCL, Orpic, Phillips 66, Rompetrol, Statoil, PBF Energy and Tesoro.

  • Resistive Components

    Smiths Interconnect

    Diamond is the best thermal conductor on earth. Combined with a low dielectric constant, it is an excellent RF dielectric material for high-frequency applications in which thermal performance is equally critical. By applying cutting-edge thin film process and extensive millimeter wave design experience, Smiths Interconnect has created a high-performance line of resistive components. The resulting products, our Diamond RF Resistives® resistors, terminations, and attenuators, are significantly reduced in size and unparalleled in average and peak power handling.

  • Vane Anemometer

    AM-4836V - Rinch Industrial Co.,Limited

    Parameters measured: Wind speed, Flow, Beaufort Scale, Wave, Temp., wind directionRange:Wind speed: 0.4-30.0m/s1.4-108.0km/h80-5910ft/min0.8-59.3 knotsFlow: 0.004-9999 m³/min0.013-9999 ft³/minB. Scale: 0-12 forceWave: 0-14mDirection indicator: 16 ways (the resolution is 22.5º)Temp. : 0-60℃ / 32-140℉Accuracy: ±2%n+2Resolution: 0.1/1PC interface: RS232C (Cable & software are optional)Can memorize 50 group dataAuto power offPower supply: 4x1.5V AA A (UM-4) batteryBattery indicator: low battery indicatorDimensions: 156x67x28mm

  • PXI 4x4 20GHz Matrix with Termination

    40-787-528-4X4-T - Pickering Interfaces Ltd.

    The 40-787 Microwave BRIC platform is designed to provide a solution for complex RF matrix applications. Using a common mechanical platform the module can be constructed to provide scalable non-blocking or blocking microwave matrix for frequencies to at least 20GHz. The standard configurations provide up to a 4x4 matrix. More complex matrix can be constructed by adding further switching functions and other devices inside the module. The matrix is available with optional terminated inputs to avoid the creation of standing waves on unconnected input cables.

  • HV Testing Transformer

    Wuhan Sangao Electrical Test Installations Limit Co.

    Inflatable Ultralight Non Partial Discharge Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The high-light characteristic of the equipment reflects the smallness in size, lighter in weight clean, oil-free, unnecessary static of field investigation, longer working life without maintenance and slightness in non-partial-discharge. It is used for the insulators' voltage-resistance testing.Major technical characteristicVoltage unit50.100.150.200.250.300.500kVCapacity unit3.5.10.15.20.25.30.50.100.150.200.300.500.1000kVAInput voltage220, 380V uniphase 50HzImpedance voltage6%≤No-load current8%≤Wave form distortion3%≤Annual gas leakage1%≤

  • Analyzers & Systems

    Guided Wave

    The optical or spectrum analyzer is the brain which transforms the signal collected by the sample interface into actionable information. Guided Wave sample interfaces (probes, flow cells) are designed for use with NIR or UV-Vis fiber optic coupled analyzers. They are designed to be rugged and reliable in harsh chemical and physical process conditions while providing optimal light transmission for long-term reliable measurements. More information is available about specific analyzers on each product page or on the process analyzer product overview.

  • Variable Reluctance Absolute Pressure Sensor

    AP10 - Validyne Engineering

    The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.

  • Power Frequency Transducer

    PP1S - Hsiang Cheng Electric Corp

    1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540

  • Pressure Sensor Kit for Changing Ranges

    DP15TL - Validyne Engineering

    The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.

Get Help