Showing results: 91 - 105 of 338 items found.
-
3164 -
Astronics Corporation
The Racal Instruments™ 3164 Series is a single-wide VXIbus Module. The 3164-2 has two 14-bit Arbitrary Waveform Generator (AWG) channels that operate independently, and the 3164-4 AWG has four channels. The maximumsample rate for each channel is 125 MS/s. All waveforms can be sampled from data previously loaded into waveform memory or loaded and output on the fly.
-
ICS Electronics
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
ICS Electronics
• VXI-5501 has a Bare Copper-clad Prototyping Board for RF and microwave modules.
-
ZT444x -
Avionics Interface Technologies
On-board calculation of over 40 waveform parameters related to voltage, time, and frequency (FFT)Multiple acquisition modes including averaging, high-resolution, peak detect, and envelopeUp to four calculation channels for waveform math, digital filtering, FFT, and more
-
310113272 -
Virginia Panel Corporation
VXI Plug & Play Plate is used with the Single Tier VXI Receiver (Part # 310 104 127) to mount the Receiver to the VXI Chassis. Flanges must be purchased from the manufacturer.
-
6084-2105 -
Astronics Corporation
The Astronics 6084-2105 digitizer includes two 125MS/s, 14-bit digitizer channels and is recommended for VXI systems that need either improved accuracy or replacement of an obsolete instrument. Wide dynamic sampling, a powerful acquisition engine, and excellent AC/DC performance ensure an upgrade for your VXI system that will preserve your legacy investment for years to come.Key features include:Dual 14-bit digitizers for SE or DIFF operation at sample rates up to 125 MS/sDC accuracy of 0.15% ± 800 µV on low voltage rangesSFDR 80 dB at 1 MHz Wide input ranges from 0.25 Vpk to 256 VpkPerformance upgrade or replacement for existing VXI applications Pre- and post-triggering availableWaveform storage of 32 M samples per channel
-
310104248 -
Virginia Panel Corporation
This 50 module receiver is rugged and designed to accommodate high I/O. With high contact point availability, the 9050 receiver is suited for larger test and measurement systems. The top tier accommodates VXI instruments and accepts VPC's interconnect adapters with the bottom tier for discrete wiring.
-
410104538 -
Virginia Panel Corporation
The 50 module ITA can be used in a number of applications to accomplish the required connection to the Unit Under Test (UUT). You can mount a VPC front or rear mount enclosure or customize your own fixture to be attached on the frame. A wide range of ITA modules are available separately for user configuration.
-
ICS Electronics
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Same design described above but without the address switch opening.* Complimentary layout support includes PCB design template and CAD layout files.
-
ZT442x -
Avionics Interface Technologies
On-board calculation of over 40 waveform parameters related to voltage, time, and frequency (FFT)Multiple acquisition modes including averaging, high-resolution, peak detect, and envelopeUp to four calculation channels for waveform math, digital filtering, FFT, and more
-
MIL-STD-1553 -
Avionics Interface Technologies
MIL-STD-1553 hardware modules for PXI, PCI, PCI Express, USB, Ethernet, VME, and VXI provide advanced features and functionality to support even the most demanding test and simulation applications.
-
ZT462x -
Avionics Interface Technologies
Bandwidth & fast sampling for a variety of applicationsEquivalent and interpolated sampling up to 400 GS/s for the ZT4610Segmented memory mode for analysis of repetitive signals and statistical analysis
-
310113299 -
Virginia Panel Corporation
Adapter Kit, Receiver, Plug & Play Plate for Agilent Technologies C- Size VXI E8400, Double Tier VXI Plug & Play Plate is used with the Dual Tier VXI Receiver (Part # 310104248) to mount the Receiver to the VXI Chassis.
-
ZT461x -
Avionics Interface Technologies
Bandwidth & fast sampling for a variety of applicationsEquivalent and interpolated sampling up to 400 GS/s for the ZT4610Segmented memory mode for analysis of repetitive signals and statistical analysis
-
6084A -
Astronics Corporation
Increases test system performance and density with this combo unit, which packages a 7.5 digit Digital Multimeter (DMM) together with a 10-bit, 1 GHz Digitizer into a single VXI slot.Replaces the Wavetek 1362 DMM, Analogic DBS Series, and Agilent VXI DigitizersDigitizer with 4 Inputs, 10-bits, 1 GHz, up to 4 GS/s and Ranges up to 500V DMM with 7.5 Digits for DC Volts, Current and Ohms with AC Volts up to 1 MHzIVI-COM Drivers and Soft Front Panels ProvidedMore Dynamic Range (by 20 dB for DMM and 12 dB for Digitizer) for Better Legacy Range Mapping