Showing results: 76 - 90 of 360 items found.
-
Flex One -
ZOLIX
Photoluminescence (PL) is the light emission from a material under the excitation by ultraviolet, visible or near infrared radiation. In semiconductor luminescent property measurements, the sample (e.g. GaN, ZnO, GaAs etc.) was usually excited by a laser (with a wavelength of 325 nm, 532 nm, 785 nm etc.), and its PL spectrum is measured to analyze the optical physical properties, such as the band gap width etc.. Photoluminescence is a high sensitivity, non-destructive analysis method, which can provide the information about the structure, composition and surrounding atomic arrangement of materials. Therefore, it is widely used in physics, materials science, chemistry and molecular biology and other related fields.
-
Vitech A1905 -
ViTec Co. Ltd
Modules A1905 are designed for pulsed or continuous illumination of objects in machine vision systems. The time of ignition (90%) and blanking (10%) of the module is less than 1 μs with jitter of the front(jitter) no more than 2 μs, which allows the modules to be used for exposure with "slow" cameras.The control input is compatible with npn, pnp, "open collector", TTL, LVTTL, RS422 (Basler racer) outputs.Modules can be made with light-emitting diodes of the following colors:Infrared - wavelength 730 or 850 nm;Red - wavelength 620-630 nm;Green - wavelength 520-530 nm;Blue - wavelength 460-470 nm;Ultraviolet - wavelength 365 or 400 nm;White - with a color temperature of 5000K.
-
FLS1000 -
Edinburgh Instruments Ltd
The FLS1000 sets the standard in both steady state and time-resolved photoluminescence spectroscopy for both fundamental research and routine laboratory applications. The system is a modular fluorescence and phosphorescence spectrometer for measuring spectra from the ultraviolet to the mid-infrared spectral range (up to 5,500 nm), and lifetimes spanning from picoseconds to seconds. All of this can be achieved through various upgrade routes, either at the time of order or in the future. Whether you are studying photophysics, photochemistry, biophysics, biochemistry, material or life sciences, the FLS1000 will enable you to reliably and accurately measure luminescence spectra and kinetics using state-of-the-art sources, detectors, acquisition techniques, quality optics and precision mechanics. The large sample chamber will house practically any type of sample accessory.
-
GTESS -
Textron Systems
The Ground Threat Emitter Sensor System (GTESS) is a modular test and training system capable of stimulating multi-spectral aircraft electro-optic sensor suites at long range. The GTESS system integrates Textron Systems’ ultraviolet (Mallina™), infrared (Phoenix) and/or laser (Phantom™) ranged stimulators with an automated tracking system to facilitate fast-moving test, training and evaluation exercises. A fully integrated camera system for effective after action review. GTESS can also work in conjunction with Textron’s radio frequency (RF) range stimulator systems (PRTS™ & HPRTS) for complete multi-spectral testing.
-
Inframet
Solar blind UV cameras are imaging devices optimized to detect ultraviolet light of wavelengths below about 280nm. Such cameras are insensitive against sunlight due to negligible sensitivity to visible and long wavelength UV light. Solar blind UV cameras are used in a series of applications like corona detection, fire detection, combustion analysis, plasma research, testing UV lamps, etc. However, highly sensitive corona detection is the main mass application and these devices are of crucial importance in electric power industry. These imaging devices enable easy detection of degraded insulators of high voltage transmission lines, distributions and substations. They can see the emission of UV light when discharges occur at defect insulators. From design point of view solar blind UV cameras are actually bispectral imaging systems built by combining true UV camera with typical visible camera. These bispectral imaging system generate output image as overlay of typical visible image with UV image of analyzed UV source.
-
KP Technology
The Ф4 Ultra-high Vacuum Scanning Kelvin Probe system gives the user full access to work function measurements under vacuum with the ability to alter the temperature from 77 K to 860 K. The Kelvin Probe measurement has resolution of 1 - 3 meV for a 2 mm tip on a conducting sample. The sample is mounted on a plate that is located on a motorized (x, y, z) translator attached to a stainless-steel vacuum chamber. Phi 4 also comes with a photoemission spectroscopy system with a tuneable source (3.4 - 7.0 eV). The deep ultra-violet (DUV) light spot measures approximately 3 x 4 mm. Absolute work function measurements can be obtained with this system in the range of 4.0 - 6.5 eV with an accuracy of 0.05 - 0.1 eV.
-
Wewon Environmental Chambers Co, Ltd.
Wewon Technology specializes in the research, development, production and sales of laboratory testing equipment system services. Through more than ten years of accumulation in the field of equipment, the business of wewon Tech is mainly divided into three fields, namely optical communication, automobile and new energy industry.Specialized equipment from Wewon Environmental Chambers Co., Ltd. includes thermal stream instrument, environmental chambers, walk in chamber, salt fog test chamber, vibration testing machine, xenon lamp aging tester, ultraviolet weather testing equipment, tensile testing machine and various IP protection level test equipment. The system characteristic of Wewon Tech thermal stream temperature test system as below technical parameters mentioned.https://www.wewontech.com/temperature-forcing-system/
-
Model T265 -
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
TROI 8800 CI -
Pemtron Co., Ltd
The PEMTRON CI Series addresses the limitations of the area of theinspection due to the diversity of wavelengths of the existing UV,and performs a clearly separated area of coating onvarious wavelengths.
-
Ofil Ltd.
Compact solar blind dual sensors UV–Visible block camera modules for UAS and sUAS, remotely controlled, having a robust rigid structure and light weight. Made for airborne inspections, surveillance, fixed ongoing observations etc. Fit for gimbaled payloads, UAVs and as OEM, providing excellent UV detectivity.
-
CoroCAM 8 UAV -
Amperis sl
*High-sensitivity UV detector, which can detect UVc light at 2.05×10-18 Watt/cm2, this allows detection of the smallest corona discharges.*9Hz (or 25Hz optional) IR radiometric camera module*Control of a limited number of camera functions from a standard RC controller using PWM or SBUS.*Remote control of all camera functions from the laptop via an Ethernet link.*Soft sync or staggered zoom of the 3 channel cameras. The IR and UV channels are digitally zoomed in, which is visible...optically zoomed in to the minimum FOV, and then digitally zoomed out.
-
UVTOUCH -
SolGel Technologies GmbH
100% touch-screen controlled Dosimetry and datalogging digital signal conversion (CAN bus) Compliant with GLP and LIMS standard Intuitive handling with NIST traceable calibration with customized spectral characteristics UVTOUCH sensor not included
-
Model T700 -
Teledyne Advanced Pollution Instrumentation
The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.
-
SPECS Surface Nano Analysis GmbH
To our customers in research and industry we offer a variety of sources for deposition, excitation and charge neutralization as well as analyzers and monochromators. Most of our sources originate from product lines which we have taken over from Leybold AG, Cologne, and from VSI GmbH. The X-ray monochromator Focus 500 and the UV monochromator TMM 302 are original developments by SPECS.Compliance with industry standards, a good price-performance ratio, stability, and longevity are the guidelines for our product development. We focus on standardized easy handling, user-friendliness, standardized software interfaces and safety.
-
ELSD-LT III -
Shimadzu Corp.
The evaporative light scattering detector (ELSD) is a general-purpose universal detector that can even detect components with no UV absorption, such as carbohydrates, lipids, surfactants, and synthetic polymers.* With exceptional sensitivity, a wide dynamic range through Analytical Intelligence features, and easy operability using LabSolutions™ software, the ELSD-LT III contributes to more effective analysis in a wide variety of fields.