Filter Results By:

Products

Applications

Manufacturers

Transient

irregular short bursts of energy.

See Also: Surge


Showing results: 481 - 495 of 596 items found.

  • Premium Automotive DMM

    597IR - Electronic Specialties Inc.

    *Highest Quality Auto-Ranging DMM Designed for Automotive Trouble Shooting *18 Test Functions, 48 Test Ranges *Peak Min/Max records transient voltages as fast as 1 millisecond *Min/Max Mode records variations in all functions *Exclusive Non-Contact IR Thermometer Adapter Included - 1022F/550C max temp readings *Also measures Temperature via Temp Probe in Both F and C *Milliseconds Pulse Width Measures Fuel Injector ON-TIME *Inductive RPM Readings for both DIS and Conventional Ignitions *Desirable 20 Amp Test Range - Dual Fuse Protection *Modern Design, the Protective Holster is Built Into the Housing *Data Hold, Auto Power-Off, + Trigger Adjust *Large LCD Display w/White LED Backlighting and 40 Segment Analog Bargraph *Blow Mold Case, Test Leads, IR Thermometer Adapter, K-Type Temp Probe, Inductive RPM Clamp and Instructions included

  • DC Power Supply

    62000H - Chroma Systems Solutions, Inc.

    Chroma’s new 62000H Series of programmable DC Power Supplies offer many unique advantages for telecom, automated test system & integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include a high power density of 15KW in 3U, precision readback of output current and voltage, output trigger signals, as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations. For high power applications, parallel up to 10 units for up to 150kW.

  • NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783107-01 - NI

    250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.

  • NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module

    782975-01 - NI

    8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.

  • Power Rail Probe, 6 GHz

    N7024A - Keysight Technologies

    The N7024A power rail probe is for users making power integrity measurements that need mV sensitivity when measuring noise, ripple and transients on their DC power rails. The probe is designed for measuring periodic and random disturbances (PARD), static and dynamic load response, programmable power rail response, and similar power integrity measurements. Many of today’s products have tighter tolerances on their DC power rails than the previous generations of these products, and the N7024A power rail probe is designed to help users ensure their products meet these tighter tolerances.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-01 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module

    785259-01 - NI

    8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-02 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785996-01 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    779994-02 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9235, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785995-01 - NI

    10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • Audio Multimeter

    AMM-1 - D'Amore Engineering llc

    The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)

  • Turnkey or PCI Cards and Software

    WinCAT Systems - GHI Systems

    # True fast transient recorder system.# 4, 8 or 16 channel models.# 1 MHZ aggregate 12 bit sampling, resolution equal to 0.024% of full scale.# 13 record lengths, user selected, 132 msec to 1,320 sec in typical 1-2-5x scope progression.# 6 programmable front end gains, user selected, equal to 0.4, 1, 2, 4, 10 and 20 volts full scale.# Software converts digitized voltages to Engineering units.# Digital Triggering, Amplitude and slope, in engineering units from digitized input signals.

  • USB Multifunction Digital I/O Module

    Model JI-4040 - Jupiter Instruments

    The JI-4040 module is a versatile, easy-to-use device for adding universal digital I/O capability to acomputer system via a USB connection. The module is comprised of 36 bidirectional I/O channels and 2 Special Function Ports (SFP). The SFP can be software programmed as a variable duty-cycle clock/pulse generator, event counter, or interval/pulse timer. The I/O is selectable to interface 5.0 V, 3.3 V, 2.5 V, or 1.8 V systems. Host to module isolation eliminates ground-loops and provides protection from noise and switching transients on external signals. The JI-4040 is available as either a desktop unit or low-cost OEM board.

  • Shock Test System

    Labtone Test Equipment Co., LTD

    Products are inevitably affected by impact, bump, free fall, tumbling etc. during production, transportation, loading and unloading as well as during the use of the products. All of these are transient excitation on the object, causing the object to produce mechanical characteristics of high speed, acceleration, strain rate instantly. These kind of characteristics are completely different from that in static load, and may cause problems to the object in terms of structural strength and stability and sometimes the object may fail. Therefore, it's necessary to study the effect of impact and reproduce the shock environment, to assess the structural strenghth and performance of the object under shock environment.

Get Help