Showing results: 376 - 390 of 707 items found.
-
AC-100 -
ZETLAB Company
The voltage amplifier for connecting piezoelectric acceleration meters, microphones, and other primary voltage output transducers to FFT spectrum analyzers with the IEPE standard current output (ZET 017-U2, ZET 017-U8, A19-U2).
-
BC 114 -
ZETLAB Company
*Piezoelectric converter of signal proportinal to the vibration speed RMS;*Standard current output signal 4…20 mA;*Used within vibration diagnostics systems as a vibration speed transducer;*Explosion-proof version.
-
Lord MicroStrain Sensing
Ideal for precise micro-position measurements, our miniature linear variable displacement transducers (LVDTs) provide accurate, repeatable measurement. Inductive contact, non-contact, slide, and spring-actuated sensors are available in various stroke lengths-- ideal in spaces where traditional LVDTs are too large. Our sensors operate in harsh environments over millions of cycles without degradation in performance
-
3000 Series -
HITEC Sensor Solutions Inc.
Button Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type provides a range of capacities up to 150 kN or 30 klb with better than ±0.5% (full scale) non-linearity. Three tapped holes are provided on the underside for ease of mounting. Fully welded cover, amplified and digitised versions are available on request.
-
RESON TC 4014 -
Teledyne Marine RESON B.V.
The TC4014-5 broad band spherical hydrophone offers a very wide usable frequency range with excellent omnidirectional characteristics in all planes. The overall receiving characteristics makes the TC4014-5 an ideal transducer for making absolute underwater sound measurements up to 480kHz. The wide frequency range also makes the TC4014-5 perfect for calibration purposes, particularly in higher frequencies.
-
DLx -
North Atlantic Industries
Linear Variable Differential Transformer (LVDT) and Rotary Variable Differential Transformer (RVDT) are transformer-type voltage/current transducers that convert a linear/rotary movement of a core/shaft to a multi-wire differential AC electrical signal. Both deliver signals linearly proportional to the position of a shaft (magnetic induction core). An LVDT/RVDT simulator is used to convert digital positional commands to corresponding AC signals.
-
Dewetron GmbH
Real drive and test bench applicationMultiple power analyzer in one instrumentUltra flexible channel configurationWide range of fundamental frequencyCAN interface for automotive and test bench linkInternal current transducer supply and TEDS support
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
CYHCS-D8 -
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
dScope Series III -
Spectral Measurement
The dScope Series III is a comprehensive and powerful measurement system for analogue and digital audio generation and analysis, including digital audio carrier parameters, acoustic transducers and Windows™ sound devices (WDM or ASIO).
-
DP-cPCI-1197 -
Data Patterns Pvt. Ltd.
DP-cPCI-1197 is a high-resolution signal-conditioning module that amplifies the signals from full-bridge based transducers. This signal-conditioning module is available on a cPCI module form factor. This module has four gain settings to accommodate a wide variety of sensor output voltages. In addition, this module has an adjustable excitation voltage to accommodate transducer excitation requirements.A high resolution sigma-delta ADC and variable gain amplifier forms the core of the signal conditioning system. Direct digital conversion and digital isolation ensures a better signal integrity in comparison with the conventional analog system.
-
CD379 -
Validyne Engineering
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
2000-R -
Bowmonk Ltd.
The Bowmonk 2000-R is our next generation electronic brake meter, featuring a built-in printer, keyboard, GPS receiver, and coming soon built-in Wi-Fi for automatic uploading of brake test results. Significant processing power and on-board storage enables the Bowmonk 2000-R to be customised for various applications. The Bowmonk 2000-R also supports an optional pedal force transducer to measure the force applied to the vehicle's footbrake during braking. Using the pedal force transducer will also identify any "braking delay" - the time between depressing the brake pedal and the brakes being applied.
-
MUCC01 -
Smartec bv
The multiplexer MUCC01 is especially designed for use in combination with the Smartec Universal Transducer Interface (UTI). The combination of the UTI and the MUXC01 makes it possible to measure multiple capacitances with a very low capacitance value and a very high accuracy (15 bits). By cascading the multiplexers it is easy to extend to the quantity of capacitors needed. Each multiplexer contains a 9 bits shift register and can handle 9 capacitors.