Showing results: 3316 - 3330 of 5366 items found.
-
NanoSync IV & NanoSync IV Low Profile -
FEI-Zyfer Inc.
The NanoSync IV is a small form factor GPS Position, Navigation, Time (PNT) and Frequency reference system that provides multiple reference outputs and includes support for NTP & PTPv2 IEEE 1588-2008. The NanoSync IV has a Rubidium oscillator and is available with a civilian C/A GPS receiver or SAASM (Rockwell-Collins MPE-S GB-GRAM or Trimble Force 22E MRU GPS receiver) for military users. The NanoSync IV is packaged in a small, rugged enclosure ideally suited for embedded electronic warfare applications.The NanoSync IV-SA-Rb has been demonstrated to be compliant to the Joint Airborne SIGINT Architecture (JASA) Version 3.0, Annex 1, for Time, Frequency, Navigation and Geodesy (TFNG), making it suitable for Electronic Warfare (EW) COMINT and ELINT applications in fixed site, airborne and shipboard environments.
-
Shenzhen Graigar Technology Co.,Ltd.
Electrochemical (fuel cell) alcohol sensor, Module changeable Test Range: 0.000-2.000mg/l (0.400%B.A.C; 4.000%oB.A.C; 4.000g/l;) Alarming level: Pass level: 0.090mg/L (could be modified) Fail level:0.250mg/L (could be modified) Accuracy: +/-10% Work temperature: -10oC-50oC Work humidity: <95%RH (No Dews) Battery: 2XAA NiMH batteries, rating capacity: 2.1AH Dimension lXbXh: (mm) 250X105X400 Indication manner: mg/l,mg/100ml,g/l ,%BAC,%oBAC optional Coin for single time: 0-15 (For 0, the tester can be tested without coin). Coin diameter: 20mm-28mm Coin thickness: 1.2mm-2.5mm Coins Capacity: about 200 pieces Straw capacity: 200pcs(⊄<=7mm) Breath sampling time: about 5 seconds continuous breath.
-
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.
-
NOFFZ Computer Technik GmbH
Increasing customer requirements, shorter product cycles and higher time to market demands dramatically influence the long-term goals in software development. With the Universal Test Platform Software Suite (UTP Suite), we introduce a robust standard that features a great set of tools for configuring, developing, analyzing, debugging and executing test sequences.
-
MPS-H-1 Series -
Matrix Technology Inc.
MPS-H-1 series DC power supply is a new generation of high-quality linear DC power supply, with remote voltage compensation function, automatic conversion of voltage stabilization and current, high stability, high reliability, high precision, and display output voltage and current at the same time. Very high cost-effective advantage.
-
NI
PXI Transfer Switch Modules offer fast insertion times and low insertion loss to switch loads at RF frequencies. The modules also have 50 impedance that helps minimize reflections of the RF signal and protect your instruments. You can program the PXI Transfer Switch Module using the NI-SWITCH instrument driver.
-
ShibaSoku Co., Ltd.
This system is suitable for DC testing of IGBT, IGBT module (1in1~7in1). Built-in hi-current switching relay circuit inside test head, it is capable ofDC testing from device itself to module. Highly accurate repeatability testing is available by high speed rise time which is suppressed its heat in hi-current
-
6420 -
Peaceful Thriving Enterprise Co Ltd
This is a device to test the 12 volt lead-acid battery of any vehicle. The tester will focus on health condition analysis of vehicle battery; it will estimate the cold cranking ampere (CCA) of the vehicle, and predict the lifetime of the battery. This will be helpful for the technician to inspect and maintain the electrical system of the vehicle. Base on the inspection, user can predict the time to replace the battery.
-
Sahi -
Tyto Software Pvt. Ltd
Cross browser and Automated Regression Testing Tool: Record and playback any web application on any browser, any operating system. Recording saves time and helps non-technical users contribute to automation. The Sahi Controller helps easily identify and experiment with elements on any browser. The same script works on all browsers.
-
Extech VB300 -
Extech Instruments Corporation
The VB300 is a G-Force datalogger which records and times 3-axis shock and vibration (acceleration) readings over its ±18g measurement range. This device will record 3-axis g-force and related peaks to provide a history of shock and vibration conditions. Complete with Magnetized/Bolt-on Mounting Base, 3.6V Lithium battery and Windows compatible analysis software.
-
FXA-103 MUX 16×2 -
Konrad Technologies GmbH
The FXA-103 is a two times sixteen channel multiplexer which allows to route analog or digital input signals from multiple sources to one measurement device. To simplify control the corresponding relays of both multiplexers are switched together and each channel is equipped with a status led. In addition, it is delivered with an installed DIN rail carrier.
-
65-225-101 -
Pickering Interfaces Ltd.
These Modular LXI Matrix Reed Relay Matrix Modules plug into our LXI Modular Chassis (model 65-200-002)—providing access to all signal connection on 200 pin connectors. They are constructed using Pickering Electronics' Reed Relays offering maximum performance and reliability as well as very fast operate times.
-
65-223-002 -
Pickering Interfaces Ltd.
These Modular LXI Matrix Reed Relay Matrix Modules plug into our LXI Modular Chassis (model 65-200-002)—providing access to all signal connection on 200 pin connectors. They are constructed using Pickering Electronics' Reed Relays offering maximum performance and reliability as well as very fast operate times.
-
65-223-101 -
Pickering Interfaces Ltd.
These Modular LXI Matrix Reed Relay Matrix Modules plug into our LXI Modular Chassis (model 65-200-002)—providing access to all signal connection on 200 pin connectors. They are constructed using Pickering Electronics' Reed Relays offering maximum performance and reliability as well as very fast operate times.