Filter Results By:

Products

Applications

Manufacturers

Showing results: 3181 - 3195 of 5359 items found.

  • Automatic Transformer Test System

    TH2840BX - Changzhou Tonghui Electronic Co., Ltd.

    ■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file

  • Automatic Transformer Test System

    TH2840NX - Changzhou Tonghui Electronic Co., Ltd.

    ■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file

  • Disturbance Recorder

    APR64 - dfv Technologie

    This equipment analyzes and records in real time from 0 to 96 analog channels and from 0 to 1536 digital channels. The APR64 equipment is a system that is completely modular and scalable by adding drawers (digital channels and local and/or remote analog channels by fiber optic, relay, synchronization)

  • Digital Line Protection System

    DLPD - GE Digital Energy

    The DLPD provides distance protection for HV and EHV transmission lines. It may be used for single or three phase tripping applications. It includes four zones of distanceprotection. User selectable pilot schemes are provided with stepdistance backup. Ground instantaneous and time overcurrentfunctions are independently selectable to be directional ornon-directional.

  • Wind Tunnel Control System

    WTCS - S.E.A. Datentechnik GmbH

    Wind tunnel facilities are important for the development of all kinds of transportation vehicles. In any kind of wind tunnel - aerodynamic, climatic or acoustic - users are interested in optimization of the valuable factor time for the performance of experiments and measurements. Aerodynamic properties exerting direct influence to fuel consumption have to be optimized.

  • Verification Suite

    Cadence Design Systems

    Using the Cadence Verification Suite, you can reduce system integration time by up to 50%, accelerating intellectual property (IP) development, system-on-chip (SoC) integration, and concurrent hardware/software development. This verification suite is comprised of core engines, verification fabric technologies, and solutions spanning these technologies.

  • Particle Counter

    TES Electrical Electronic Corp.

    Monitoring air pollutant souce from dust, pertochemical industry, steel-making plant, thermal power plant, restaurant, smoke, burning plnats, driving automobiles.The meter is a real time air quality monitor instrument used to monitor the concentration of PM2.5 humidity and temperature in the indoor environment.

  • Static Honest Meter

    Sataton Instruments Technology CO., Ltd

    Static honest meter is professional designed to determine the attenuation of static electricity, corona discharge time, static voltage attenuation half-life, static decay curve and other electric property of fiber, yarn, fabric, textile or plate materials. It is suitable for measuring the diffusibility of static in the testing samples.

  • IOLITE LX

    Dewesoft d.o.o.

    IOLITE LX - Embedded Data Acquisition SystemIOLITE LX is an embedded data acquisition system based on a low power Linux based ARM processor with open architecture being able to act like a data logger, real-time system, and signal conditioning frontend, all at the same time.

  • FiberScout | Fault Identifier & Singlemode Fibre Length Tester

    TS21 - Yamasaki Optical Technology

    The TS21 Fiber Scout was designed and developed by Yamasaki as a cost effective and simple solution for identifying faults and testing the length of singlemode fibers. This lightweight, rugged, dustproof and water resistant piece of test equipment can list up to 8 results at one time and has three brilliant functions.

  • INNOTESTER

    PK-160/160PL - Pansco, Ltd

    INNOTESTER (PK-160/160PL) combines the function of a smart cable tester, network tester, port identifier and organizes with the capability to identify up to 100 cables run at a time, and 8 Test + ID remotes allows one person to test 8 cables runs up to 600 meters.

  • MIL-STD-1553 Module

    QPM-1553 - Abaco Systems Inc

    The QPM-1553 provides the highest level of performance, flexibility and interface density for MIL-STD-1553A/B on a PMC (PCI Mezzanine Card) module. The QPM-1553 is integrated with powerful software that reduces development time. All 1553 databus functionality is supported from our advanced API (Application Programming Interface).

  • Well Control

    Herrin Design & Manufacturing Co.

    The Herrin Design Model 1644 Well System Pump Control is designed to provide a cost effective means of controlling water system reservoir levels. Through precise monitoring, the Well Control is able to reliably sense reservoir water levels by measuring water pressure at the well head. By monitoring reservoir levels at the well head, it is possible to mount the water system controls in one location, eliminating the costly communications link--leased lines or buried cables--between reservoir level sensors and the pumps. Typically, mechanical sensors at the reservoir deteriorate or are broken frequently due to weather; and communications lines are a large, continued expense.The Well Control tolerates temporary variations in water pressure due to surges and usage. The pump will not start until there is a constant low pressure level for 2-3 (variable) minutes (OFF TIME). This insures the pumps are activated only when necessary. Once the pump is turned on, it remains on for a preset period of time--up to 24 hours (ON TIME). During the pump cycle, the control does not rely on water pressure measurements to indicate if the reservoir is full. This feature eliminates sporadic pumping due to pressure variations created during the pumping cycle.

  • DC Power Source for Standard Lamp

    DC502 - Lisun Electronics Inc.

    DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA

  • DC Resistance or Conductance of Insulating Materials

    ASTM D257 - National Technical Systems

    These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.

Get Help