DI-9M-8/08 -
Sugisaki Meter Co., Ltd.
Ideal for daily inspection of electric screwdrivers. Uses OW joints that do not require rewinding. Five channels of pass/fail judgment conditions can be saved, and settings can be made simply by switching channels even if the tightening conditions change. Efficient measurement without rewinding by "OW joint".
-
3110 -
Metrel d.d.
The MI 3110 EurotestIM is a perfect tool for testing of permanent integrated or portable Low Voltage Electrical Installa-tions supplied by Generator or Transformer and protected by an IT earthing system. Designed for simple but efficient safety testing of Integrated IT Earthing System powered with LV Generator or Transformer! With a single, pre-programmed AUTO SEQUENCE® with sub-tests and adjustable limits it is possible to perform all the necessary verifications of safety limits of a specific LV IT installation.
-
HH2611 -
Colluck Company Limited
Handy, quick response and easy to use tool. Safe to use Non-Contact testing 90-220V AC voltage. Delect AC voltage without connecting into the wire circuit. Very bright LED and buzz sound alarm if voltage is present. Used to detect where the wire is broken. Used to detect whether an outlet is present of voltage. Used to detect a broken Christmas bulb out of a series of connected Christmas bulbs
-
M70 -
HT Italia Srl
M70 is a mobile device dedicated to measuring Insulation resistance with test voltage up to 1000VDC and Continuity of protective and equipotential conductors with current of 200mA in private and industrial electric installations.
-
Model 27012 -
Chroma ATE Inc.
To meet the high accuracy and low price requirements for LCM TV test device, Chroma 27012 that integrates the signal and power source provide a complete test solution for LCD Module. Its LVDS, TTL (Option) signal source fully complies with the digital signal standard, meanwhile with the 24V, 12V, 5V, 3.3V DC source output it is able to supply power to VDD, Backlight for LCM test without obtaining external power source. Equipped with the interface of single key to switch the Timing, Pattern and Program rapidly for test in auto or manual mode, the 27012 is able to provide a direct and convenient test environment for LCM TV by its complete hardware configuration and easy operation.
-
Hanwa Electronic Ind. Co.,Ltd.
◆Adaptable to the following international standard waveform;JEDEC, ESDA, AEC, and JEITA◆This system’s uniquely short discharge circuit is made possible by its original mechanical design.◆The short circuit minimizes the influence of inductance and capacitance on the data.◆The use of a single circuit ensures data stability for each device pin tested.
-
MRC ltd.
* Compact plastic case, suitable for use under poor working conditions. Test at any angle, even upside down.* Wide measuring range. It can measure the hardness of all metallic materials. Direct display of hardness scales HRB, HRC, HV, HB, HS, HL* Large screen (segment LCD), showing all functions and parameters. With EL background light.* Large capacity memory could store 100 groups information.* Datapro Software to connect with PC via RS232 port. Micro printer support* Software calibration function.
-
KEOLABS sas
The ContactLAB test platform provides fully configurable reader signal emulation for validation of ISO 7816 contact smart cards and Single Wire Protocol (SWP) USIM for NFC enabled mobile handsets.
-
69133 -
Klein Tools, Inc.
Quickly reveals shorts or broken circuits in all types of electrical devices and controls.Tests for continuity of circuit with power off.Bulb in handle glows when circuit is complete (bulb included).Pointed 3-3/4'' (95 mm) probe gets right to the problem.Deluxe 4'' (102 mm) long handle with removable nylon cap holds replaceable bulb and battery.36'' (914 mm) test lead with alligator clip.Uses one AAA battery (not included).Replacement bulb (Cat. No. 69131)
-
VT14 -
Chauvin Arnoux Metrix
12 V to 690 V voltage test (7 diodes)Indication of polarity by " + " and " – " diodesImpedance: 400 kΩOperating frequency: DC and 50/60 Hzovervoltage protection up to 1,000 VIEC 61010 600 V CAT IIIPowered by 1 x 9 V 6LR61 battery (supplied)
-
MP -
MAGMESS Magnet-Messtechnik
Computer aided measuring desk for automatic measurement of hysteresis loop of hard magnetic materials. Use pole pieces with integrated measuring coils, or J-compensated surrounding coils.
-
UNITES Systems a.s.
VPC G12 interface - interchangeable fixturesQuick exchange of test applicationMinimum of equipment in the fixture - fixture only as contacting interfaceManual fixtures ATXFixture identification - automatic test program loadingConnection to external meas. instrumentsControled by SCADUS / LabViewSelftest of internal cards and connected instrumentsCentral test program, configuration and datalog files location possibility (server)Uninterruptible power supply for PC
-
MS-154 -
Misum Systech Co., Ltd.
This equipment is used for inspecting condition of cell or pack through charge/discharge operation, to make a precise measurement of performance characteristic, consumption current, ID/TH Resistor, initial resistance. Depends on the setting value, OK or NG will displayed
-
Psiber Data Systems
The PingerPro Series provides a powerful combination of physical layer tools to troubleshoot copper/fiber links and LAN tools to identify and repair a wide range of network problems.
-
I2C -
telos EDV Systementwicklung GmbH
The most common use of an I2C interface is to send and receive data in compliance with the I2C specification. This implies that the device we are talking to is known to conform to the I2C standard, as well.