Filter Results By:

Products

Applications

Manufacturers

Test Systems

group of interoperable devices whose integration perform a common test purpose.

See Also: Systems, Equipment, System Integrators, System Test, System Integration


Showing results: 4351 - 4365 of 5304 items found.

  • Liquid Thermal Conductivity Instruments

    THW-L1 - Thermtest Instruments

    The Transient Hot Wire (THW-L1) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity, thermal diffusivity, and specific heat instrument for measurement of liquids and pastes in accordance with ASTM D7896-19. The THW-L1 was designed with speed and operational simplicity in mind. With a single measurement of 1 second in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity, thermal diffusivity, and specific heat. The THW-L1 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a thin heating wire 40 mm in length and is completely inserted into the sample to be tested.

  • Crank Angle Measurement System

    CP-5110B Detector/CA-6000B Amplifier - Ono Sokki

    CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5110B Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-5120 / 5130 Slit disk.CP-5110B Fiber Optic Crank Angle Detector makes it possible to detect the crank angle required for various engine performance tests such as combustion analysis with high accuracy and high response. As it has a light projecting and receiving method with an optical fiber, it provides outstanding vibration and noise resistance without a built-in electric circuit in the detector.CA-6000B Crank Angle Amplifier inputs a signal of crank angle detector and outputs a TTL level angle signal and a 1P / R pulse signal.

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • PXIe SSD Storage Unit

    DM-4M.2-3U - Conduant express

    The Big River™ DM-4M.2-3U PXI Express storage unit provides up to 3.8TB* of M.2 SSD storage capacity. With a PCIe x8 Gen3 host interface, the DM-4M.2 delivers high-speed data rates for sequential writes of 3.25GB/s** and sequential reads of 3.41GB/s** to PXI Express based systems. The single slot design of the DM-4M.2 increases the availability of valuable chassis space, allows for maximum storage flexibility. The DM-4M.2 complies with PCIe Gen3 protocol standards. The product is commonly used in the industrial control, test and measurement fields. The DM-4M.2 operates under Windows, Linux, Unix, Solaris and VxWorks.

  • Resistors

    Vishay Intertechnology, Inc.

    A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.

  • General Data Acquisition Device With Strain Gage Measurement

    Spider-80SG - Crystal instruments

    The Spider-80SG is a high precision, general purpose data acquisition device featuring strain gage measurement. This device can be used in a variety of physical and measurement tests. The Spider-80SG can acquire data from a strain gage or a wide range of measurement quantities. A variety of general purpose and strain gage based sensors are supported. The Spider-80SG is built on the proven outstanding performance and reliability of Crystal Instruments’ DSP-based hardware platform. It features the same form factor as other Spider-80X front-ends from Crystal Instruments and can be configured into one measurement system with excellent compatibility and scalability. This gives the Spider-80SG capabilities to reliably acquire data from multiple sensors and for multiple measurement quantities simultaneously.

  • PXIe-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    780587-12 - NI

    PXIe, 7-Channel, 10 A PXI Signal Insertion Switch Module—The PXIe‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).

  • PXIe-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module

    780587-14 - NI

    PXIe, 7-Channel, 40 A PXI Signal Insertion Switch Module—The PXIe‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXIe‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs).

  • PXIe-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    780587-41 - NI

    PXIe, 300 MHz, 8x12 PXI RF Matrix Switch Module—The PXIe‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXIe‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • PXI-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    778572-41 - NI

    300 MHz, 8x12 PXI RF Matrix Switch Module—The PXI‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXI‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • RMC-8357 , 2.1 GHz, 1U Rugged Rack-Mount External Controller for PXI

    785672-01 - NI

    2.1 GHz, 1U Rugged Rack-Mount External Controller for PXI—The RMC‑8357 is a rugged 1U rack-mount controller for PXI- or PXI Express-based systems intended for test and measurement applications requiring rack-mount controllers. It features up to two Intel Xeon eight‐core processors that support up to 32 GB of RAM. The RMC‑8357 offers hot-swappable fans, options for redundant power supplies, and support for RAID arrays, which allows multiple hard drives to be configured for high performance for mission‐critical, physically demanding applications. The RMC‑8357 meets the PXI standard’s mechanical shock and vibration specifications and functions over wide operating ranges.

  • RMC-8357, 2.1 GHz, 1U Rugged Rack-Mount External Controller for PXI

    785673-01 - NI

    2.1 GHz, 1U Rugged Rack-Mount External Controller for PXI—The RMC‑8357 is a rugged 1U rack-mount controller for PXI- or PXI Express-based systems intended for test and measurement applications requiring rack-mount controllers. It features up to two Intel Xeon eight‐core processors that support up to 32 GB of RAM. The RMC‑8357 offers hot-swappable fans, options for redundant power supplies, and support for RAID arrays, which allows multiple hard drives to be configured for high performance for mission‐critical, physically demanding applications. The RMC‑8357 meets the PXI standard’s mechanical shock and vibration specifications and functions over wide operating ranges.

  • PXIe-8522, 4-Port, 1000BASE-T1 PXI Automotive Ethernet Interface Module

    787312-01 - NI

    PXIe, 4-Port, 1000BASE-T1 PXI Automotive Ethernet Interface Module - The PXIe-8522 is a 1000BASE-T1 unshielded twisted pair (UTP) module for developing applications with the NI‑XNET driver. With this hardware, you can develop applications that require Automotive Ethernet to test … and validate automotive electronic control units (ECUs). The PXIe-8522 provides up to four independent endpoints or up to two network terminal access points (TAPs). It features onboard hardware timestamping and can act as up to four separate 802.1AS masters or slaves, so it can synchronize with an external network as well as the rest of a PXI system. The PXIe-8522 also provides LEDs on the front panel to help you monitor the network link and activity.

  • Compute Express Link (CXL)

    Teledyne LeCroy

    Compute Express Link (CXL) is a new high-speed CPU-to-Device and CPU-to-Memory interconnect designed to accelerate next-generation data center performance. CXL technology maintains memory coherency between the CPU memory space and memory on attached devices, which allows resource sharing for higher performance, reduced software stack complexity, and lower overall system cost. This permits users to simply focus on target workloads as opposed to the redundant memory management hardware in their accelerators. CXL is based on a PCI Express 5.0 Physical layer with speeds up to 32GT/s. Teledyne LeCroy provides protocol analysis test equipment to support development and debug of CXL based devices.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.