Filter Results By:

Products

Applications

Manufacturers

Test Systems

group of interoperable devices whose integration perform a common test purpose.

See Also: Systems, Equipment, System Integrators, System Test, System Integration


Showing results: 4336 - 4350 of 5296 items found.

  • PXI-2799, 40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module

    782359-01 - NI

    40 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2799 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2799 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module

    778572-14 - NI

    7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    778572-12 - NI

    7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780875-01 - NI

    Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.

  • PXI-2599, 26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module

    778572-99 - NI

    26.5 GHz, 50 Ω, Dual SPDT PXI RF Relay Module - The PXI‑2599 is a general-purpose single‑pole double‑throw (SPDT) switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2599 is also well-suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module

    778572-10 - NI

    68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • Averaging Extensometers for ASTM D5656 Shear Tests

    Model 4013 - Jinan Testing Equipment IE Corporation

    The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Programmable Digital Attenuator

    LDA-602EH - Vaunix Technology Corporation

    The LDA-602EH has a large attenuation range of 120 dB with an exceptional 0.1 dB step size, allowing for both precision and accuracy during fading tests or device characterizations. This attenuator also features a fast 15 us switching speed, an operating temperature from -30oC to 50oC, a maximum RF input of +28 dBm, and is priced at $875. The LDA602-EH operates with a low insertion loss of 9 dB to 6 GHz, an input IP3 of +55 dBm and a typical VSWR of 1.3:1. Easily programmed for ATE applications, the LDA digital attenuators are a cost effective solution whether you are in engineering, the production test lab, or in the field. Units are ROHS compliant and can be used with any PC or laptop computer with USB 2.0 port (or powered USB hub) and Windows operating system. Lab Brick Signal Generators are provided with easy to use Lab Brick GUI software, 32 and 64 bit API DLL files, LabVIEW and Linux compatible drivers.

  • LED Driver Aging Rack

    LEDRACK-100W192P - Lisun Electronics Inc.

    • Application range: LED driver and multi channel driver power aging. It has equipped with computer operation and monitor system. The working condition can be set by the computer, and the computer will record real time data to do statistical analysis. • The parameters of load can be set freely on the software, to monitor the real time voltage, current, and power etc • Load mode: CC, CV, CR, CP, and LED • Aging Control System includes: ON/OFF control signal output; Signal of relay switch control; K type thermocouple temperature acquisition • The channels are parallel connected under arbitrary load mode, which can allow product power expansion • The LED Driver Aging rack will design according to customer’s LED driver power and aging quantity per time • Automatic current switching function (optional) • AC power meter to measure modules, and test power input characteristics (optional) • Temperature monitoring function at product zone (optional) • PWM dimming and two sets of logic control signal function (optional)

  • Radiator Flow Test Machine

    8601 - Hydraulic Technology, Inc.

    The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.

  • Load Cells

    WIKA Alexander Wiegand SE & Co. KG

    Load cells are designed as a special form of force transducer for use in weighing equipment. These force transducers enable very high measurement accuracies of 0.01 % and 0.05 % of FS. Load cells are used in the widest variety of application areas, including platform, filling, belt and packaging scales, dynamic test systems as well as electronic precision, price-labelling and industrial scales. WIKA provides you with all typical and widely used load cell geometries such as single point load cells, bending and shear beam load cells, s-type load cells, canister load cells and compression force load cells. In addition, there are corresponding mounting kits and complete weighing modules available.

  • Liquid Thermal Conductivity Instruments

    THW-L1 - Thermtest Instruments

    The Transient Hot Wire (THW-L1) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity, thermal diffusivity, and specific heat instrument for measurement of liquids and pastes in accordance with ASTM D7896-19. The THW-L1 was designed with speed and operational simplicity in mind. With a single measurement of 1 second in duration, small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity, thermal diffusivity, and specific heat. The THW-L1 utilizes a non-stationary measurement approach and rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a thin heating wire 40 mm in length and is completely inserted into the sample to be tested.

  • Crank Angle Measurement System

    CP-5110B Detector/CA-6000B Amplifier - Ono Sokki

    CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5110B Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-5120 / 5130 Slit disk.CP-5110B Fiber Optic Crank Angle Detector makes it possible to detect the crank angle required for various engine performance tests such as combustion analysis with high accuracy and high response. As it has a light projecting and receiving method with an optical fiber, it provides outstanding vibration and noise resistance without a built-in electric circuit in the detector.CA-6000B Crank Angle Amplifier inputs a signal of crank angle detector and outputs a TTL level angle signal and a 1P / R pulse signal.

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • PXIe SSD Storage Unit

    DM-4M.2-3U - Conduant express

    The Big River™ DM-4M.2-3U PXI Express storage unit provides up to 3.8TB* of M.2 SSD storage capacity. With a PCIe x8 Gen3 host interface, the DM-4M.2 delivers high-speed data rates for sequential writes of 3.25GB/s** and sequential reads of 3.41GB/s** to PXI Express based systems. The single slot design of the DM-4M.2 increases the availability of valuable chassis space, allows for maximum storage flexibility. The DM-4M.2 complies with PCIe Gen3 protocol standards. The product is commonly used in the industrial control, test and measurement fields. The DM-4M.2 operates under Windows, Linux, Unix, Solaris and VxWorks.

Get Help