Filter Results By:

Products

Applications

Manufacturers

Switching

Controls consisting of a mechanical or electrical or electronic device for making or breaking or changing the connections in a circuit. (www.cogsci.princeton.edu)

See Also: Switching Matrix, High Voltage Switching, Switching Matrices, Multiplexers, General Purpose Switch


Showing results: 3211 - 3225 of 4320 items found.

  • 80 Channel Relay Switch

    DP-VXI-4503 - Data Patterns Pvt. Ltd.

    DP-VXI-4503 is a 80 channel, one Form C (SPDT) relay switch designed as a C size VXI module. This high density switch module is designed with a register based interface occupying only one VXI slot. This module uses two Form ‘C’ relay switches. Out of the two contacts in each relay, one is used to provide the status of the relay through read back and the other is used for switching purpose.The user can write the command for the selected channels on to the primary latch of the FPGA section. Readback is available to confirm the selected commands. On command, the data from the primary latch is transferred to the secondary latch. The relay driver section provides the necessary drive to switch ON the relays. The buffers in this section drive the relay coils.This module features a back plane trigger for VXI triggered operation. On receipt of the back plane trigger the programmed relays will be energised/de-energised. Alternatively, software trigger can be used.

  • Analog Power Supply

    Type NPS-2412 - National RF, Inc

    National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.

  • PXI Single 10 Channel MUX, XLR Connectors

    40-735-902-S2 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Single 36 Channel MUX, SMB Connectors

    40-735-912-S4 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Single 18 Channel MUX, BNC Connectors

    40-735-902-S3 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI Dual 18 Channel MUX, 96-Pin SCSI Connector

    40-735-912-S1 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI 36 Channel Data Comms MUX, 96-pin SCSI

    40-735-912 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • PXI 18 Channel Data Comms MUX, 96-pin SCSI

    40-735-902 - Pickering Interfaces Ltd.

    The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.

  • 83x SPDT High-Density PXI Relay Module

    40-100-001 - Pickering Interfaces Ltd.

    Configured with 83 SPDT relays, this high-density 2 Amp PXI Relay module was originally designed for applications in Aerospace and Defense requiring a higher density 2 Amp alternative to our current 52 SPDT module (model 40-139). This new Relay Module is suitable for applications requiring medium power switching with very high density. It features a 2 Amp current capacity and voltages to 200VDC/140VAC.

  • PXI 12x8 Matrix, 1 Pole Screened

    40-512-021-S - Pickering Interfaces Ltd.

    The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.

  • Test Equipment

    ST6300 - Shenzhen Star Instrument Co., Ltd.

    The ST6300 portable three-phase meter test equipment is suitable to conduct commissioning and testing for energy meter manufacturers and meter test departments. It adopts modular design and incorporates DSP and PWM switching amplifier technologies. Users are able to control the equipment via keypad or PC-based software. It simultaneously measures the errors of three energy meters. It connects to a meter rack via its COM port.

  • MTA Wiring Analyzer

    2650 - DIT-MCO International

    DIT-MCO's newest test solution, the Model 2650, incorporates modularity so that the system conforms to your testing needs. The modular switching units can rack-and-stack in a cabinet providing concentrated test points or can be distributed around the Unit Under Test (UUT) eliminating long, cumbersome adapter cables. Or you may reconfigure the system at any time when your needs or the UUT changes.

  • Microwave Power Amplifier 10W 100 MHz to 20 GHz

    GT-1000B - Spanawave Corporation

    The Spanawave GT-1000B Microwave Power Amplifier offers linear high-power amplification across multi-octave bands. It is ideal for testing in EMC, wireless communications applications and Defense EW systems. For EMI/EMC and standards laboratories, the GT-1000B with 100 MHz to 20 GHz frequency range allows broadband testing without band switching or swapping narrow band amplifiers resulting in faster and more accurate testing.

  • PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber

    40-852A-318-M62.5-HI - Pickering Interfaces Ltd.

    The 40/42-852A-318-M62.5-HI is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.

  • PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber

    40-852A-318-M50-HI - Pickering Interfaces Ltd.

    The 40/42-852A-318-M50 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.

Get Help