Filter Results By:

Products

Applications

Manufacturers

Stability

the degree of being anchored.

See Also: Measurement


Showing results: 946 - 960 of 1062 items found.

  • Trace Moisture Analyzers

    Model 8800T - Teledyne Analytical Instruments

    The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. The​se structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.

  • Laser Open Path H2S Detector

    GD1 - Teledyne Gas & Flame Detection

    The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants. At the heart of the detector is a tuneable laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases.The GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs.Supplied with worldwide hazardous area approvals. Suitable for use in systems with SIL 2 requirement.

  • Bench Power Supply, Single, Adjustable, Fixed, 1 Output, 13.3 V, 14.5 V, 15 A

    72-8110 - Tenma

    The 72-8110 is a compact switch mode Power Supply features a very compact footprint that makes it an ideal match for portable communications equipment. Its 50% duty cycle surge rating is comes in handy in demanding transmitting situations. It is also perfect for two-way radio (including HF) and audio equipment including auto sound and multimedia systems. This fixed voltage switch mode power supply is designed with high RFI stability and is especially suitable for two-way radio and communications equipment. Constant current circuitry is used for overload, short-circuit and over-temperature protection. Output current and voltage drop to a safe level when any fault occurs. This power supply also has over voltage protection to prevent connected equipment from damage.

  • Ultra Low Level DC Voltage Amplifiers

    EM Electronics

    The EM A10 is a low level amplifier module for sensitive measurements, data collection and systems, where signals below 1 nanovolt may be measured. It is ideal for the input unit for precision voltage measuring systems, requiring voltage sensitivity for measuring low noise and low impedance sources. The noise level of the A10 is equivalent to a perfect resistor of about 20 ohms. When used with a digital voltmeter, steady one nanovolt digits may be displayed, with a response time constant of less than a second. The input voltage stability of the A10 is very high, with the drift around a nanovolt per degree C. The input connectors are made from pure copper. The input impedance is very high, and is time dependent, determined by the loop gain.

  • Soldering Station

    SM-898D - MCH Instruments Co.,Ltd.

    *Using micro-processor PID program control technology, precise dual digital display hot air gun and the stability of the actual temperature of the soldering iron, fast automatic temperature compensation feature further enhanced temperatures.*The amount of wind, air flow, temperature soldering iron are adjustable.*The air gun holder is a magnetron (or light control), holding the handle when the system will automatically enter the working mode; handle is placed on the shelf when the system enters standby mode automatically.(One more than the 898D Auto Sleep off function)*System with automatic cold wind function, can prolong the life of the heating element.*This product uses "brushless fan" as a source of air, reduce noise, improve work efficiency

  • Optical Oxygen Sensors

    Barben Analytical

    The analyzer is suitable for direct field installation (NEMA 4X) in hazardous area (Class I, Division 2). The optical fiber sensor platform allows small inline sensors to be installed into sample tubing lines (1/4”), flow cells using NPT fittings, or directly into tanks or process lines using our retractable “hot tap” sensor design. BOS optical oxygen sensors are impervious to typical O2 poisons (H2S) and interferences (combustibles, magnetic, CO2 and H2) with high accuracy and long-term stability measurements without the need for complex or advanced sample conditioning systems. The threaded version of the optical sensor has optional Dual Seal (ANSI/ISA 12.27.01) classification for high pressure applications up to 1200 PSIG (82.7 BAR).

  • Soldering Station

    SM-899D - MCH Instruments Co.,Ltd.

    *Using micro-processor PID program control technology, precise dual digital display hot air gun and the stability of the actual temperature of the soldering iron, fast automatic temperature compensation feature further enhanced temperatures.*The amount of wind, air flow, temperature soldering iron are adjustable.*The air gun holder is a magnetron (or light control), holding the handle when the system will automatically enter the working mode; handle is placed on the shelf when the system enters standby mode automatically.(One more than the 898D Auto Sleep off function)*System with automatic cold wind function, can prolong the life of the heating element.*This product uses "brushless fan" as a source of air, reduce noise, improve work efficiency.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • 6U VPX PCIe to XMC Expansion Board

    VP69601 - LinkedHope Intelligent Technologies Co.,Ltd.

    VP69601 is a 6U VPX PCIe to XMC expansion board. Onboard there is a x8 PCIe 3.0 interface, and through a PCIe connector the x8 PCIe 3.0 turns into 2 x8 PCIe 3.0 linking to 2 XMC cards. The PCIe Switch IC on VP69601 supports DMA, so direct data transmission between peripheral cards can be realized.VP69601 can be installed in a standard VPX chassis and work as a peripheral board. VP69601 carries two XMC ports, through which users can expand various functional XMC cards needed.Apart from the traditional Air Cooling design, Linkedhope○R provides a Conduction Cooling version to guarantee working stability of VP69601 in extreme and vibration environment and in an extended working temperature from -40℃ to +70℃.

  • IRIG Time Code Receiver & Generator Module

    TCR180 - Meinberg Funkuhren GmbH & Co. KG

    The module TCR180 has been designed to receive and to generate IRIG-A/B/G, IEEE 1344, IEEE C37.118 or AFNOR NF S87-500 time codes. It is used in applications like data acquisition, standalone computer time synchronization (for systems without a network connection or higher accuracy requirements) or as an IRIG converter device. The frequency locking of the master oscillator to the time code system enables this module to generate fixed and programmable standard frequencies with high accuracy and stability. Various oscillator options allow the cost efficient implementation of different requirements concerning the accurracy of the outputs. The generator of the IMS-TCR module generates pulses per second and per minute and per hour. Four programmable outputs are also available. The pulses are synchronized to UTC-second.

  • PXI-6683, TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module

    782109-01 - NI

    TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module - The PXI‑6683 timing and synchronization modules synchronize PXI and PXI Express systems using GPS, IEEE 1588, and IRIG‑B to perform synchronous events. The PXI‑6683 can generate events and clock signals at specified … synchronized future times and timestamp input events with the synchronized system time. The PXI‑6683 features an onboard temperature-compensated crystal oscillator (TCXO) that can be disciplined to GPS, IEEE 1588, and IRIG‑B for long-term stability. You also can use the PXI‑6683 to route clock signals and triggers with low skew within a PXI chassis or between multiple chassis, providing you a method for synchronizing multiple devices in a PXI system.

  • PXI-6683, TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module

    782110-01 - NI

    TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module—The PXI‑6683 timing and synchronization modules synchronize PXI and PXI Express systems using GPS, IEEE 1588, and IRIG‑B to perform synchronous events. The PXI‑6683 can generate events and clock signals at specified synchronized future times and timestamp input events with the synchronized system time. The PXI‑6683 features an onboard temperature-compensated crystal oscillator (TCXO) that can be disciplined to GPS, IEEE 1588, and IRIG‑B for long-term stability. You also can use the PXI‑6683 to route clock signals and triggers with low skew within a PXI chassis or between multiple chassis, providing you a method for synchronizing multiple devices in a PXI system.

  • PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit

    781743-01 - NI

    PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.

  • PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit

    782431-01 - NI

    PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.

  • Semi-Rigid Cable Set, 3.5 Mm (Test Port) To 3.5 Mm

    85131D - Keysight Technologies

    The Keysight 85131D is an 53 cm (21 in) long1 semi-rigid cable set composed of a 3.5 mm female2 to PSC-3.5 mm female connector and a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss of 16 dB or better. Insertion loss is 0.3 * sqrt(f) + 0.2 dB, where f is frequency in GHz, for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability1 of the Keysight 85131D is less than 0.06 dB and phase is 0.16 * f + 0.5, where f is frequency in GHz.