Filter Results By:

Products

Applications

Manufacturers

Sources

The origin.


Showing results: 2836 - 2850 of 2910 items found.

  • Zero Bias Schottky Detectors

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.

  • Complete Solution for Developing & Testing Discrete Voltage-Level Interfaces

    M4KDiscrete Module - Excalibur Systems, Inc.

    The M4KDiscrete module provides a complete solution for developing and testing discrete voltage-level interfaces. The M4KDiscrete contains control I/O registers that are memory-mapped and may be accessed in real time. The module supports twenty programmable I/O discretes that can record or control the external discretes that are connected to it. In addition, the module can record changes in the input discrete with an associated time tag via a built-in FIFO. Output discretes are open collector, capable of handling up to 32V with a maximum sink current of 100 mA each. Ordering Information:The user can set each discrete:• Either as input or output.• Either to TTL (0 – 5V) or Avionics (0 – 32V) voltage levels on inputs and• Either enable or disable external debounce on inputsThere is a 4092 Word FIFO (a string of 1023 discrete entries) containing the data and time tags.The M4KDiscrete module is supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.

  • Services

    OPTICOM GmbH

    Besides our product line of perceptual quality testing products, we offer extensive services in the field of QoS testing, where you can immediately benefit from the technology source - the expertise and experience of our developers. This is most often the case for field studies, or during the evaluation of network components, either if the customer's demand for QoS testing is a temporary one, or simly, if no engineering resources are available otherwise. For instance, OPTICOM could provide comprehensive QoS consulting, including not only objective but as well subjective evaluation, like we did during the introduction of a novel digital satellite broadcast service in the U.S. As a major contributor to the ITU standards, OPTICOM can also provide expertise in implemenation and conformance testing of independent implementations. Even if your PESQ implementation works according to specs, you should consider that an independent conformance test seal could be an asset that will leverage the value of your product from a marketing persepective.

  • Luminance Colorimeter

    XYL-VI - Lisun Electronics Inc.

    The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.

  • Digital Colorimeter & Illuminance Meter

    CHC-I - Lisun Electronics Inc.

    This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.

  • Conductive Footwear Tester

    SLTM-1 - Walter G. Legge Company Inc.

    SLTM-1 Conductive Footwear Tester checks conductive footwear automatically. The SLTM-1 Conductive Footwear Tester automatically and accurately measures the exact amount of resistance in conductive footwear and body grounding devices, ensuring a static control environment. It is ideal for dangerous, potentially explosive areas or areas in the electronic industry where static can destroy sensitive components. Stand on the foot plates and the unit’s direct-reading dial with graduated, color-coded scale indicates the exact amount of resistance. Shipped complete and ready to operate. Has 8 feet of 18-3 type SJ power cord that plugs into any grounded 120-volt AC power source. This unit measures 17 x 12 inches and weighs less than 6 1/2 lbs. All conductive footwear and body grounding devices, such as LEGSTATS, must be worn in pairs. SLTM-1 passes conductive footwear with resistance less than 2.5 MEG Ohm.

  • PXI Based Multifunction Measurement and ICT Instrument

    PXI-501 - Konrad Technologies GmbH

    The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.

  • Portable Mass Spectrometer

    Continuity - BaySpec, Inc.

    Continuity™ - the most sensitive portable mass spectrometer designed to provide quality and reliable mass spectrometer analysis outside of the laboratory. Continuity™ was created to provide even higher sensitivity, greater specificity with built-in MS/MS, and larger mass range coverage than its ground-breaking counterpart Portability™. Like its counterpart, Continuity™ requires no sample preparation and is compatible with almost any ambient ionization source including ESI, APCI, TD-ESI, TD-APCI, and DBDI. It allows for a broad range of applications from clinical to drug to chemical and biological threats analysis. The user-friendly interface, rapid deployment, and real-time results make Continuity™ a great solution for fast, dependable, and highly sensitive field analysis for any user in any location. This potable mass spectrometer is the excellent solution for various challenging applications, including vapors/liquids/solids, CWAs/TICs, biological/biomedical, forensic, agriculture, food safety, security, and explosives.

  • Medium-size Reverberation Chamber

    E-Series - Emite Ingeniería SL. Ed

    The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.

  • VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM

    HFDF - National RF, Inc

    National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.

  • PLD Systems

    Pulsed Laser Deposition - Neocera, Inc.

    Is a versatile thin film deposition technique. A pulsed laser (~20 ns pulse width) rapidly evaporates a target material forming a thin film that retains target composition. This unique ability of stoichiometeric transfer of target composition into the film was realized first by the research team led by Dr. Venkatesan at Bell Communications Research, NJ, USA, nearly 30 years ago while depositing high temperature superconducting (YBa2Cu3O7) thin films. Since then, PLD has become the preferred deposition technique where ever thin films of complex material compositions are considered. Another unique feature of PLD is its ability for rapid prototyping of materials. The energy source (pulsed laser) being outside the deposition chamber, facilitates a large dynamic range of operating pressures (10-10 Torr to 500 Torr) during material synthesis. By controlling the deposition pressure and substrate temperature and using relatively small target sizes, a variety of atomically controlled nano-structures and interfaces can be prepared with unique functionalities.

  • Image Intensifiers

    Inframet

    Image intensifier tubes (IITs) are vacuum tubes that amplify a low light-level image to observable levels. Image intensifier tubes are the most important modules of night vision devices that play crucial role in defense/security/industrial applications.Technology of manufacturing of image intensifier tubes is very difficult and performance parameters of modern IITs varies even within the same technological process. Next, test report offered by manufacturers cannot be fully trusted because there are some differences in test methods used by different manufactures. Further on, there are literature sources presenting conflicting claims of different manufacturers. It is quite common to find on the world market two night vision devices (or two image intensifier tubes) of the same data sheet parameters but of totally different image quality. Inverse situation is possible, too. Due to reasons mentioned above testing image intensifier tubes is of critical importance for both their manufacturers, manufacturers of night vision devices (NVDs) and final users of NVDs.

  • LANDTEK Digital Muscle Dynamometer Muscle Strength Tester FM-204M50KG

    FM-204M50KG - Guangzhou Landtek Instruments Co. Ltd.

    LANDTEK Digital Muscle Dynamometer Muscle Strength Tester FM-204M50KGApplications:Making job task analysis and ergonomic analysis simple and accurate, it is ideal for workplace design, strength assessment and ergonomic research.Details:Force Rang:±50kgf,±490N,±110LbfResolution:0.01kgf,0.1N,0.1LbfAccuracy:±0.5%FS ± 1DigitUnit:kgf, gf, N, LbfMeasurement State:Peak Value Measurement, Real Time MeasurementDisplay:2 Reversed 4 Digit LCDPower Off:10 Minutes Auto Power Off, Manual Power OffBacklight:BacklightSafe Load:150%FS (Buzzer Alarm Over 110%FS)Power Supply:2x1.5 AA(UM-3) Battery or 5VDC Power SupplyOperating:0°C~40°CConditions:< 80%Surrounding:No Vibration Source or Corrosive Medium AroundWeight:705 gSize:host machine:170mm*72mm*35mmhandspike:315mm*Φ30mm Instrument stents:155mm*95mm*35mmAccessories:Standard Accessories:ManualCarrying CaseInstrument stents4 M3*18 screwsE-1005Optional Accessories:External USB power supply cableE-1004For quotation please feel free to contact Lisa Li. Thank you.

  • 3D Guidance®

    Northern Digital Inc.

    The 3D Guidance® electromagnetic tracking solution delivers exceptional performance and value for OEM image-guided interventional and therapy systems and medical trainers that require real-time navigation tracking capabilities. The 3D Guidance solution tracks 6DOF sensors that can be embedded into OEM instruments such as ultrasound probes, rigid and flexible scopes, and laparoscopic tools. Continuous in-vivo tracking is maintained through difficult anatomy, even when sensors are out of sight. Low latency and fast update rates ensure the most subtle tool movements are instantly tracked and visualized within the OEM host interface. The 3D Guidance solution is available in the driveBAY™ and trakSTAR™ configurations, as based on the Electronics Unit. The trakSTAR is a standalone desktop unit that connects to a direct power source. The smaller driveBAY fits inside the drive bay of a computer, OEM imaging cart, or medical trainer/simulator, using the host’s power supply. Both share the same tracking accuracy and reliability. The ready-to-use configuration facilitates cost-effective integration and speeds time to market.

  • Precision Capacitance Meter

    TH2638C - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

Get Help