Filter Results By:

Products

Applications

Manufacturers

Signal

detectable impulse of electromagnetic radiation or quantum state superposed.

See Also: Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners, Fidelity, Hunting


Showing results: 6031 - 6045 of 8184 items found.

  • PCI Very High Density Multiplexer, 5-Channel, 16-Pole

    50-670C-021-5/16 - Pickering Interfaces Ltd.

    The 50-670C-021-5/16 is a 5-channel, 16-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.

  • PCI Very High Density Multiplexer, 49-Channel, 4-Pole

    50-670C-022-49/4 - Pickering Interfaces Ltd.

    The 50-670C-022-49/4 is a 49-channel, 4-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.

  • PCI Very High Density Multiplexer, 10-Channel, 8-Pole

    50-670C-021-10/8 - Pickering Interfaces Ltd.

    The 50-670C-021-10/8 is a 10-channel, 8-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.

  • PCI Very High Density Multiplexer, 99-Channel, 1-Pole

    50-670C-021-99/1 - Pickering Interfaces Ltd.

    The 50-670C-021-99/1 is a 99-channel,1-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.

  • 1211a Optical Receiver/Distribution

    Precise Time and Frequency, Inc.

    To complement the range of high quality frequency and timing references, Precise Time and Frequency, LLC. has now introduced a new Optical Time Code Receiver, with Auto Switching, a full complement of time code outputs, and Ethernet/RS232 remote monitoring/control interface.In addition to the auto switching capability, the new ptf 1211A delivers up to thirty six channels of Time Code outputs, including re-transmission of the optical input. The unit can accept a pair of inputs (usually from separate primary and backup sources), and provides monitoring of both the inputs and outputs for signal integrity.If the primary input fails, the unit will automatically switch to the backup input and indicate a primary signal fault.Full remote monitoring and control via RS232 and Ethernet interfaces includes telnet, http (web browser), and SNMP protocols.

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • PXI Single 24x8 Matrix, 2 Pole Switching

    40-521-022 - Pickering Interfaces Ltd.

    Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.

  • Physical Layer Switching Systems for copper LAN, WAN, DSL, Telco apps with RJ style connectors.

    RJ Series - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • SMPTE Studio Camera Hybrid Fiber Converters & Power Supplies

    SMPTE-HUT Series - Multidyne

    We work in an industry of hybrid workflows and solutions, but sometimes we need authentic innovation that changes how we work. MultiDyne’s next-generation SMPTE-HUT Series is the definition of a pure solution that elevates the live production workflow. SMPTE-HUT universal camera transceivers free SMPTE-based camera chains from the limitations of hybrid copper and fiber cabling, and removes interferences associated with copper connectivity. Camera operators instead have a plug-and-play system that requires only two stands of single-mode fiber - reducing costs, weight, and set-up times – while ensuring the best possible signal integrity. With options to multiplex camera signals, boost the optical range of cameras and regenerate optical power over fiber, SMPTE-HUT is a purist’s solution for remote broadcasting, sports production and other long-distance SMPTE studio camera applications.

  • Millimeter Wave Continuously Variable Waveguide Attenuators

    Fairview Microwave Inc.

    Our millimeter wave variable waveguide attenuators allow designers and engineers to test their systems at various signal strengths and attenuation values to determine the optimum signal performance of the system. The key feature of these waveguide attenuators is that the attenuation level is adjusted using a built-in micrometer which enables repeatable and rapid re-setting to different attenuation levels without the need for additional external components. Our waveguide attenuators handle varying attenuation levels from 0 to 30 dB over the specified band allowing the designer to tune the attenuation level needed for the application. These continuously variable waveguide attenuators cover a broad frequency range of 33 to 110 GHz in five bands and also display flat performance across a wide band with low insertion loss.

  • Clock Synchronization

    Analog Devices Inc.

    Analog Devices Clock synchronizers are designed for wired networking applications, providing the clock redundancy functionality needed to maximize system uptime. Our technology supports clock synchronization with common standards, including 1 pulse per second (PPS) output signal from a GPS receiver. GPS signals are broadly available and utilize an extremely stable atomic clock as its time base, but they are often noisy. Systems rely on the IEEE1588 timing protocol to establish synchronous communications across the wired network, including synchronous Ethernet and synchronous digital hierarchy (SDH) to optical transport network (OTN) mapping/demapping. The IEEE1588 protocol has emerged as the preferred method for Clock synchronizing systems throughout both computer networks and local area networks (LAN).

  • Displacement Transducers

    Procter & Chester Measurements Ltd

    Pressure: Measures gas or liquid pressure. Pressure is an expression of the force required to stop a fluid from expanding. The transducer generates a signal from the pressure imposed upon it. Torque: Measures the torque (or twisting motion) on a static or rotating system. The static torque element has little movement and therefore more economic to manufacture and purchase. Rotary or dynamic torque is more complicated as the signal needs to be transferred using slip rings, wireless telemetry or rotary transformers/inductance technology so that the strain gauged shaft can continuously rotate. Displacement: Measures distance. The displacement transducers that PCM offer are slightly different to standard units. They have a strain gauge/wheatstone bridge. The benefit here is that if the customer has existing electronics that uses strain gauge/load cell technology, they can use them with these sensors.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

Get Help