Filter Results By:

Products

Applications

Manufacturers

Serial

a bus that can be used with almost any device transmitting a single stream of data.

See Also: Bus, Parallel, I2C, LIN, Camera Link, Can bus, ExpressCard, Fieldbus, FireWire, RS-232, RS-485, PCI Express, Serial ATA, Serial Peripheral Interface, SMBus, Serial Analyzers, Serial Digital Interfaces, Serial Communications, Serial Data


Showing results: 946 - 960 of 1356 items found.

  • Dual-Channel, Tri-Port Per Channel, for Extended Cabling up to 20 Meters

    FW1 - North Atlantic Industries

    The FW1 provides IEEE 1394 (Firewire) high-speed serial communications. The module is provided with a direct PCIe interface to the local (on-board) processor, or, an external host processor for board platforms that support external PCIe connectivity. These module(s) are not supported with the classic memory register-based NAIBrd Software Support Kit (SSK) API libraries. These communication function modules support device control and management via standard native OS (Linux) FireWire device driver.

  • Load Cell Transmitter

    MODEL SST-HV - Transducer Techniques, Inc

    The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • SWR True Antenna Analyzer

    COMM-connect

    SWR True Antenna Analyzer is a versatile analyzer covering all major communication bands from 30MHz to 2700MHz. The SWR True will analyze antennas and cables. Measurements are represented graphically as VSWR or Return Loss plots. The built in PLL synthesized generator offers a superior accuracy with small step size. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The SWR True instrument is small, handy and light weight battery operated with more than 6 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.

  • Load Cell Transmitter

    MODEL SST-LV - Transducer Techniques, Inc

    The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • LVDS Digital I/O with Virtex-6 FPGA - XMC

    Model 71610 - Pentek, Inc.

    - 32 bits of LVDS digital I/O- One LVDS clock- One LVDS data valid- One LVDS data suspend- Supports LXT and SXT Virtex-6 FPGAs- DMA controller moves data to and from system memory- Up to 2 GB of DDR3 SDRAM- PCI Express Interface- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O to the carrier board- RoHS Compliant Lead-Free Version Available

  • UV Meters

    USHIO DEUTSCHLAND GmbH

    USHIO developed a UV meter series to measure intensities of UV radiation. As an add-on, the temperature is also registered. You can decide between the high-end UV meter UIT-250, and UIT-201. The former has a wider measurement range, allows the measurement of energy doses and has the capability to transfer the data via a serial communication protocol to a PC. Various sensors are available. The most popular sensors have center wavelengths at 254 nm, 365 nm or 410 nm.

  • PXI Differential Fault Insertion Switch Modules

    Pickering Interfaces Ltd.

    Pickering's PXI Differential Fault Insertion Switch Modules support multiple channels of two-wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to externally applied fault conditions. *Two module types are available: Two wire fault insertion module suitable for CAN Bus and FlexRay.*High bandwidth two wire fault insertion module suitable for Gigabit Ethernet, AFDX and BroadR-Reach.

  • Data Server and Recorder

    TTC ADSR-4003 - Curtiss-Wright Defense Solutions

    The TTC ADSR-4003-1 is an instrumentation recorder with a built-in file server capability. It has two 1000BASE-T Ethernet ports and can accept up to three removable solid-state memory cartridges. The ADSR-4003-1 memory cartridges (DTDs) use Serial ATA (SATA)-based media and are available in industrial or commercial temperature versions. Data can be downloaded from the cartridges using one of the ADSR Gigabit Ethernet ports, by using the DTU-2000 desktop Data Transfer Unit or using FTP.

  • Buffered Analog Crosspoint Switches

    Analog Devices Inc.

    Analog Devices buffered video crosspoint switches offer multiple configurations from 8x8 up to 32x32 channels with gain of 1 or 2 and are offered in LQFP, LFCSP, and BGA packages. These crosspoint switches can be programmed either in serial or parallel modes and are used primarily for routing high speed signals, including composite video (NTSC, PAL, SECAM) and component video (YUV, RGB) in applications such as studios, video on demand, in-flight entertainment, surveillance, and video teleconferencing.

  • Character Generators

    HORITA Co., Inc.

    GPS Video Titler adds real-time GPS data to SD analog composite video for recording or viewing. The video output from the GPT-50 is the same as the video input plus a caption of GPS position and other data, depending on input code format. The GPT-50 works with NTSC RS-170A or 625/50 SD analog composite video and RS-232 or RS-422 serial inputs, in several selectable formats. You can select from a total of 12 GPS input code formats.

  • HDMI SCDC/EDID Controller

    AJSC-1 - Allion

    The Allion AJSC-1 is a SCDC/EDID Controller that was designed for the latest HDMI 2.1/1.4 source/sink compliance electrical testing. It is used for HDMI source/sink device testing with the aim of controlling and emulating HDMI 2.1/1.4 EDID, SCDC signals. As the AJSC-1 is compatible with test equipment from Tektronix and Keysight, it is truly an adaptable and multi-functional test device.This test fixture can be managed through a serial interface using a terminal emulator software such as Tera Term. Windows-based GUI software is also available.

  • Datalogger IO-Expander

    IOX-370 - HORIBA, Ltd.

    The I/O Expander takes as a central component of Immission measuring station the calculation of averages, controlling function controls and saving data. The raw data are analog, serial or read in via Ethernet. Automatically when certain events occur, a message by SMS or e-mail will be sent. The transmission of measurement data in the control center is via a modem or network. For configuration and visualization software IOVIS Lite is included. Furthermore, the stored values can requested with the integrated Web interface from any browser.

  • Heavy Duty Dissolved Oxygen Meter

    Extech 407510 - Extech Instruments Corporation

    407510 is a Heavy Duty Dissolved Oxygen Meter with PC interface. Recall Min, Max and Average readings. Featuring Data Hold and a Built-in RS-232 PC serial interface with optional data acquisition software and data logger. Auto power off saves battery life. DO measurements from 0 to 20.0 mg/L. Complete with 0.8" (20mm) diameter probe on 13ft (4m) cable, 5 membranes, rubber holster, 9V battery and hard case.

  • Cybercast System VBI Data Inserter

    VDI-2000S - En Technology

    The VDI-2000S Video Data Inserter accepts data in either RS-232 or RS-422 serial format, then inserts the data onto an NTSC/PAL composite analog video signal. It can encode any of the standard VBI data formats plus the super-robust EnXpress' format at data rates from 4800 baud to 115,200 baud. The rugged self-contained metal enclosure has a number of mounting options from desktop, to rear side-rail rack mounting, to ganged front-side or rear-side rack mounting.

  • CANbus

    ADLINK Technology Inc.

    ADLINK's Intelligent Remote Data Acquisition & Control Modules (NuDAM) are designed for data acquisition systems based on PCs and other processor based equipment with standard serial I/O ports (RS-232 or RS-485 with auto direction control).The modules convert input/output signals to engineering units and transmit/receive, in ASCII format, to/from any host computer with an RS-232 or RS-485 port. NuDAM modules are the key components in flexible and cost effective remote data acquisition and control systems.