Filter Results By:

Products

Applications

Manufacturers

Sensors

detect a physical event then translate to a representative analog signal.

See Also: Measurement, Detectors, Meters, Transducers


Showing recent results 3121 - 3135 of 3180 products found.

  • 32-Channel, 25 MHz, 100 MB/s PXI Digital I/O Module

    PXIe-6536 / 779988-01 - NI

    32-Channel, 25 MHz, 100 MB/s PXI Digital I/O Module—The PXIe‑6536 can continuously stream data over the PXI Express bus. It's an ideal solution for interfacing and testing image sensors or display panels. The module is also well-suited for other common digital applications such as pattern I/O, change detection, protocol emulation, or other custom digital interfacing. It features selectable voltage levels and per-channel directional control of the digital lines.

  • 32-Channel, 50 MHz, 200 MB/s PXI Digital I/O Module

    PXIe-6537 / 779989-01 - NI

    32-Channel, 50 MHz, 200 MB/s PXI Digital I/O Module—The PXIe‑6537 can continuously stream data over the PXI Express bus. It's an ideal solution for interfacing and testing image sensors or display panels. The module is also well-suited for other common digital applications such as pattern I/O, change detection, protocol emulation, or other custom digital interfacing. It features selectable voltage levels and per-channel directional control of the digital lines.

  • 32-Channel, 10 MHz, 40 MB/s PXI Digital I/O Module

    PXIe-6535 / 780695-01 - NI

    32-Channel, 10 MHz, 40 MB/s PXI Digital I/O Module—The PXIe‑6535 can continuously stream data over the PXI Express bus. It's an ideal solution for interfacing and testing image sensors or display panels. The module is also well-suited for other common digital applications such as pattern I/O, change detection, protocol emulation, or other custom digital interfacing. It features selectable voltage levels and per-channel directional control of the digital lines.

  • Optical Measurement

    Sylvac

    • Vertical optical measuring machine for static and dynamic measurement of various elements on small cylindrical parts.• The parts can be mounted between two centres or held in place using various accessories.• Attractive design and robust construction with many new features: New touch screen control panel for easy operation directly at the workplace, bi-telecentric optical system, high resolution CMOS camera, precision sliding headstock with integrated and protected daily standard, quick and easy accessory changing system, integrated temperature sensors, dynamic LED indicator of the general status of the measured part (GO/NG) and operator messages. Equipped with an exclusive optics tilting system.• Machines specially designed to measure threads such as, parallel, trapezoidal, conical, round, square, conical, worms, ball screws, bone screws, dental implants, etc.• Reflex SCAN+ concept for measuring parts without prior programming at the touch of a button• Delivered complete with a PC and the Reflex SCAN+ software, which allows a multitude of elements to be measured easily and intuitively.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Thermal Imaging Camera

    KT-320 - Sonel S.A.

    Solid and portable tool for daily tasks. This is the main goal when designing a line of budget cameras with a visible spectrum lens. Modern IR sensors available in three resolution versions are supported with the visible spectrum lens, which allows operation in four modes: IR, visual, PIP (picture in picture) and MIF (contours visible on IR image). A highquality image is presented on a clear display with backlighting adjustment. Despite the low price, the camera has been equipped with a set of the essential, but necessary tools for analyzing and correcting images/measurements. The results of the work can be saved on an SD card or sent via USB or WiFi for further processing. Professional software for thermogram analysis completes the unit. This makes the camera an ideal tool for maintenance personnel, electricians, the construction industry and others, in their daily tasks. Thanks to state-of-the-art technologies and solutions, the cameras of the Sonel company ensure full control and flexibility in various situations, and are an ideal tool for both novice users and professional thermographic inspectors.

  • Thermal Imaging Camera

    KT-250 - Sonel S.A.

    Solid and portable tool for daily tasks. This is the main goal when designing a line of budget cameras with a visible spectrum lens. Modern IR sensors available in three resolution versions are supported with the visible spectrum lens, which allows operation in four modes: IR, visual, PIP (picture in picture) and MIF (contours visible on IR image). A highquality image is presented on a clear display with backlighting adjustment. Despite the low price, the camera has been equipped with a set of the essential, but necessary tools for analyzing and correcting images/measurements. The results of the work can be saved on an SD card or sent via USB or WiFi for further processing. Professional software for thermogram analysis completes the unit. This makes the camera an ideal tool for maintenance personnel, electricians, the construction industry and others, in their daily tasks. Thanks to state-of-the-art technologies and solutions, the cameras of the Sonel company ensure full control and flexibility in various situations, and are an ideal tool for both novice users and professional thermographic inspectors.

  • Thermometers

    PCE Instruments

    At PCE you will find both a contact and non-contact thermometer for measuring and recording temperature. There is a thermometer to measure different temperature ranges between -200 and 1767ºC / -328 ... 3212ºF. Measurement of temperature is done in many different sectors. We also offer a thermometer that can indicate temperature in ºC, K (Kelvin) and ºF, as well as another that is water resistant.A wide range of thermal elements and type-K sensors are available for the thermometer. ISO calibration certificates, which include a laboratory calibration, can be ordered for most models in our thermometer range. Thermometers are instruments we use to measure the temperature of people or things.The most used and known thermometers are mercury thermometers used to measure peoples temperature and consisting of a graduated glass capillary and a pool of mercury in one end, but there are many types of thermometers such as digital thermometers that we have introduced which take temperature measurements on contact with an object these are suitable for any sector of industry. We even have infrared or laser thermometer to take measurements at distance, without contact.

  • CONTAMINATION MONITORING

    Semilab

    There is no disputing the detrimental effect of metallic contamination on the integrity of the critical gate oxide used in integrated circuits. During high temperature processing contamination in the silicon wafer often precipitates as a defect at the Si/Dielectric interface or segregates to the dielectric in either case it has the potential to cause pre-mature device failure and a reduction in product yield. The probability of metallic contamination impacting yield is a function of the chip size (e.g. technology node/critical dimension) and the defect density (e.g. the amount of contamination), such that as device dimensions decrease, maintaining yield requires a corresponding reduction in contamination. Figure 1 clearly demonstrates the reality of this relationship over the past 25 years, during which time the IC industry has experienced a more than 3 orders of magnitude reduction in typical background Fe concentration observed in new fabs. More importantly is the near-term projection, where over the next few years another order of magnitude reduction is needed to meet the requirements of state of the art Si IC manufacturing; with white pixel reduction in CMOS Image Sensors being a major stimulus for this effort.

  • Scientific Cameras

    Thorlabs, Inc.

    Thorlabs' Scientific-Grade Cameras are specifically designed for microscopy and other demanding applications. The Zelux™ CMOS cameras have small footprints and provide cost-effective solutions for general-purpose imaging applications. Kiralux® cameras have CMOS sensors with high quantum efficiency in a compact housing and are offered in monochrome, color, NIR-enhanced, and polarization-sensitive versions. Our polarization-sensitive CMOS camera is ideal for materials inspection, flaw detection, and other advanced techniques using polarization. The Quantalux® monochrome sCMOS cameras are fast frame rate imagers that combine high dynamic range with extremely low read noise for low-light applications. They are available in either a passively cooled compact housing or a hermetically sealed TE-cooled housing. We also offer scientific CCD cameras with a variety of features, including versions optimized for operation at UV, visible, or NIR wavelengths; fast-frame-rate cameras; TE-cooled or non-cooled housings; and versions with the sensor face plate removed. An intuitive software package, API and SDK for developers, and third-party software support provide options for custom system control and image acquisition.

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    NI-9238 / 783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. … When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • Laser Doppler Surface Velocity Meter

    LV-7000 series - Ono Sokki

    The LV-7000 series detects speed, uneven speed, distance, length of moving object or rotating object without contact. By contacting with 2 sensors, it enables to calculate difference in velocity/length between the two points in real time and output with 3,000 ppm of accuracy. The frequency response can be expanded up to 20 kHz, which achieves to understand phenomena and evaluate mechanical systems at high speed, efficiently, and accurately. It is useful for evaluation of motor control and behavior measurement, improving parts quality, and reducing loss of material.

  • Non-contact Io/Ior Leakage Clamp Meter

    MCL-800IRV - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.

  • Low Input Bias Current Op Amps (≤100 pA)

    Analog Devices Inc.

    Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.

Get Help