  • Insulation Resistance Tester 600V AC/DC

    IRT803 - UEi Test & Measurement Instruments

    The IRT803 Digital Insulation Resistance Tester has a 600V AC/DC measurement capability and auto ranging. It features a backlit display that shows test function and measured value. And is backed by a 1-Year limited warranty.

  • High Resistance Neutral Grounding Devices

    Hilkar

    HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.

  • Winding Resistance Tester with Demagnetisation Circuit

    WRT-10D - ndb Technologies Inc.

    The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.

  • 4 2/3 Digital Resistance Meter

    CS2-RS - Chuan Sheng Electronics Co., Ltd.

    CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.

  • High Coil Resistance Reed Relays

    Series 118 - Pickering Electronics

    The Pickering Series 118 is a range of very sensitive reed relays that are ideal for portable electronic instruments or other applications where low power consumption and a very small footprint is important. They have 5 volt coils with a resistance up to 2200 Ohms and the option of an internal diode.

  • Linear Polarization Resistance (LPR) Monitoring

    Metal Samples Company

    The electrochemical technique, commonly referred to as Linear Polarization Resistance, is the only corrosion monitoring method that allows corrosion rates to be measured directly, in real time. Although limited to electrolytically conducting liquids, the response time and data quality of this technique make it clearly superior, where applicable, to all other forms of corrosion monitoring.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TW Series - IBEKO Power AB

    RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Advanced Series - IBEKO Power AB

    TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.

  • Circuit Breaker Contact Resistance Meters

    Vanguard Instruments Company, Inc.

    The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.

  • DC Hipot with Insulation Resistance Tester

    297 - SCI

    Our Model 297 is a simple-to-use Hipot Tester with the built-in ability to easily test Insulation Resistance and Ground Continuity (Low Current Continuity) in a one-box solution. The 297 is capable of performing Hipot Tests in both AC & DC currents. Make testing simple with common sense security settings. PLC Remote allows you to make Hipot Testing safer with Personal Protective Equipment (PPE).

  • Solid State Relays with Low ON Resistance

    Series CD - Teledyne Defense Electronics Relays & Coax Switch

    ​The CD series Solid-state Relay utilizes the latest technology to provide a low ON resistance. The control circuit is buffered to enable the relay to be driven directly from standard CMOS or open collector TTL logic circuits. Available options include short circuit protection and current overload protection or a status output line.MSL 1CD relays are controlled by 3.8-6VdcC = Through-hole mount SC = Surface mountAvailable options include:CD00CF 2A, 60Vdc LoadSCD00CF 2A, 60Vdc LoadCD01CF 2A, 60Vdc Load; control statusSCD01CF 2A, 60Vdc Load; control statusCD20CD 1A, 60Vdc Load; short-circuit protectionSCD20CD 1A, 60Vdc Load; short circuit protectionCD21CD 1A, 60Vdc Load; short-circuit protection & control statusSCD21CD 1A, 60Vdc Load; short circuit protection & control status

  • Skid (Portable Skid Resistance Tester)

    MRC ltd.

    (also known as the British Pendulum Tester) is an essential tool for anyone with a duty to minimize the risk of accidents arising as a result of slippery roads and floor surfaces. This device is also used to investigate the cause of accidents after they have taken place.

  • Digital Earth Resistance Tester, ERT-1502

    Neutronics Manufacturing Co.

    Our Earth Tester is a very successful replacement of the conventional generator type hand tester. This device is most extensively used to test the earthing installation in numerous power based industries, electrical traction systems and telecommunication networks.

  • Analog Insulation Resistance Tester (CE)

    MIS-A - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *The single and fluorescent scale indicator for 3 ranges insulation measurements enabled easy observation. *Especially, useful when working in dark place.*Hand free and continuous measurements with custom made switch.*Safe design with built in automatic discharging function for any capacitors present in the circuit.*The voltage in the circuit can be pre-checked without any switch operation for safe insulation measurements.*Compact, light weight and heavy duty rugged case.