Showing results: 61 - 75 of 182 items found.
-
MegaPhase, llc
Optimized Super SMA Connectors feature a 32 GHz operating frequency, leading the market in precision reflection (VSWR) performance. MegaPhase, with its team of design experts, drives innovation in RF/Microwave connectors and improvement of interconnects supporting aerospace, satellite, military and telecommunication applications. These connectors are Space Qualified.
-
Zircon -
Acoustic Engineering
The Zircon is a loudspeaker-microphone probe for measuring in situ the absorption and reflection properties of surfaces. These may be indoor surfaces, such as in concert halls and gyms, or outdoor surfaces, such as road surfaces (ISO 13472-1), sound barriers installed in a free field (NF S 31-089) and traffic noise reducing devices (CEN/TS 1793-5)
-
TE3000-series -
LBA Group, Inc
The TE3000-series of RF vector network analyzers have full vector measurement capability, and accurately resolves the resistive, capacitive and inductive components of a load. The user can display the vector impedance plus a range of related parameters including SWR, reflection coefficient, return loss and R-L-C equivalent circuit.
-
15435A -
Keysight Technologies
The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters.Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications.The converters are fitted with SMA connectors, one male, one female.
-
VS-OSP -
Ametek Scientific Instruments
The VersaSCAN OSP integrates the Base with a high-accuracy, high-speed laser displacement sensor. The OSP technique uses diffuse reflection mechanism to measure topography of a sample. OSP can be used to measure topography, as a very sensitive leveling mechanism, or charting topography to be implemented with other scanning probe techniques for constant-distance mode operation.
-
TVA100 -
KRÜSS GmbH
Our Top View Analyzer – TVA100 is the only instrument in the world to use the top-view reflection method for measuring the contact angle of a liquid on a solid from above. The innovative measuring method is particularly suitable for measurements in depressions and on concave surfaces where drops cannot be analyzed using the conventional side view.
-
LXinstruments GmbH
The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.
-
Photonfocus ag
Innovative 3D cameras from Photonfocus offer completely new possibilities for future-oriented laser triangulation applications. The photon3D platform is optimized for high frame rates and high sensitivity and offers robust algorithms for determining the laser line in the FPGA of the camera. Photonfocus has optimized these algorithms in order to suppress artifacts such as reflections.
-
Exosens Group
Photonis designed the Micro Pore Optics detector to be used in X-Ray imaging applications. Its perfectly square, flat channels are optimized to allow X-Ray and UV photons to be focused or collimated due to the total external reflection at a grazing angle (<2°). Micro Pore Optics are installed on a number of international space missions.
-
R42XXE -
Elmika
The R42XXE Vector Network Analyzers are designed for measuring of S-parameters, VSWR and impedance of waveguide networks in the full frequency ranges of standard waveguides between 33 and 170 GHz. Frequency accuracy is ±0.2%. The measurement range of reflection factor modulus is from 0 to 1. The measurement range of reflection factor phase is from 0 to ±180° for 0.1< |Гx|<1 with accuracy ±7.5 o in 18-75 GHz frequency range and ±9.6° in 75-170 GHz frequency range. The measurement range of transmission factor phase is from 0 to ±180 o with accuracy ±(5+0.1 |Ax|) o for Ax >-50 dB in frequency range to 75 GHz, for Ax >-30 dB - to 170 GHz. Data can be displayed in the rectangular, Smith or polar diagrams. VNA requires Personal Computer with USB interface.
-
NI
PXI Transfer Switch Modules offer fast insertion times and low insertion loss to switch loads at RF frequencies. The modules also have 50 impedance that helps minimize reflections of the RF signal and protect your instruments. You can program the PXI Transfer Switch Module using the NI-SWITCH instrument driver.
-
Dewetron GmbH
A speed and angle sensor using a black/white tape which is glued on a rotating part. The reflection is converted into a TTL signal, bandwidth 100 kHz. The sensor consists of a tiny electronics part and a 5 m fiber optic cable terminated with a M6 screw. Thus areas where space is very limited still can be reached conveniently.
-
PIMACS CO., LTD.
The visibility is an important factor for road markings, traffic signs, road studs as well as high-visibility material such as warning clothes and Heavy good vehicles (HGV's) contour safety marking.The measurement of retroreflectivity is essentially a measurement of the reflectance of material under specified geometrical and spectral conditions. Instruments are available for measuring the retroreflectivity of various reflection materials.
-
TM500 -
T&M Tools Limited Co
TM500 Power Cable Fault Locator adopts international advanced electronic testing technologies and SCM technology, and combines low-voltage pulse reflection and pulse current testing methods, is suitable for the precise range finding of power cable high resistance, flashover, disconnection, and low resistance. Low-voltage pulse reflection method applies to test the range of the low resistance and broken line, and the length and wave velocity of various cables. Pulse current testing method can be divided into breakthrough high-voltage flashover and DC high-voltage flashover for the high resistance and flashover cable fault finding.
-
HPL-200 Series -
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
The research level of photosynthetically active radiation (PAR), PPF and PPFD measures the PPFD measurement of the outdoor environment, the canopy of the plant in the greenhouse and the growth room, and the PPFD measurement of the reflection or under the canopy (transmission) in the same environment. Quantum sensors are also used to measure ppfd in water environments, including saltwater aquariums where corals grow.