Showing results: 826 - 840 of 1196 items found.
-
AFC -
Intepro Systems
The AFC Series products are single and three phase AC Power sources ranging from 0.5kVA to 2000kVA. This AFC series has a continuous and adjustable output voltage between 5~300V. This allows for quick and convenient 3 scales of preset voltage for high and low voltage simulation. Power is supplied by state-of-the-art IBGT pulse width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance. With up to 90% efficiency the AFC minimizes heat dissipation so less infrastructure cooling is required.
-
Apogee Instruments, Inc.
The fan has an ingress protection (IP) rating of 55, virtually eliminating moisture and dust ingress. At full speed the power requirement is 1 W (80 mA at 12 V DC). To conserve power fan speed can be reduced, via pulse width modulation (PWM), to 0.3 W at night or when wind speed is greater than 3 m s-1 without loss of accuracy. If the fan is continuously operated at full speed lifetime is rated at 50,000 hours (5.7 years). The fan includes a tachometer, allowing RPM to be mounted to detect obstruction of the fan.
-
MSG1M / MSG2M / MSG3M -
Aplab Limited
- Wide frequency range- Sine, triangle, square, ramp, pulse, TTL (Sync) & DC outputs- Low distortion high resolution on low frequency output attenuation up to 80dB- Variable DC offset control- Four digit digital display with frequency indication in Hz, KHz, MHz/Amplitude display
-
Baseline 9400 TDR/ICE -
K&S Engineering and Scientific Ltd
BASELINE 9400 TDR/ICE - the unique cable diagnostic system: - A state-of-the art cable fault locating instrument containing a high speed data recorder, capable of capturing and evaluating 40 million samples of electrical data per second, while also featuring amplifiers, attenuators and an adjustable pulse generator.
-
RGA Series -
Hiden Analytical Ltd.
Systems for the examination of components present in a vessel or evolved from a process. HALO RGA – for residual gas analysis. 3F Series RGA – triple filter mass spectrometers for analytical applications. 3F-PIC – pulse ion counting detection for fast event studies. Measures the concentration of gases and vapours in real time.
-
Pulse Instruments
Whether your application is characterizing a massive mosaic of CCDs for the next great observatory, designing a faster FLIR for a weapons-guidance system, or production-testing a CMOS image sensor for a digital camera, Pulse Instruments can supply you with a fully-integrated test system that allows you to focus on your yourdevice, not on your test system.
-
PI-31000 -
Pulse Instruments
The Pulse Instruments PI-31000 IEEE Interface Card is a standard GPIB Interface card offered by National Instruments. This interface card is used in applications where the PI-2005 Pattern Generator or other instruments are controlled from a remote system CPU, or it can be used as the system controller when the CompactPCI CPU is the system computer.
-
DEI Division -
Berkeley Nucleonics Corporation
is optimized for high impedance capacitive loads, driving extraction grids and deflection plates, and pulsing or gating power tube grids. It generates an output voltage of 6,000 volts with rise and fall times less than 60ns, with very flat voltage pulses from 160 nanoseconds to DC into a capacitive load.
-
DFA100 -
Doble Engineering
The DFA100 Dielectric Fault Analyzer is a handheld survey tool used to identify and locate partial discharge, particles, and mechanical defects.With three measuring modes, continuous, phase and pulse, the DFA100 uses its acoustic emission sensor to find in-service acoustic signals produced by partial discharge and loose components.
-
FMSS -
TOEI INDUSTRY CO, LTD.
The necessity of evaluation for media by thin film and high speed magnetic recording increases as high density of magnetic recording media. This equipment is newly-developed one which applies any time-range and pulse magnetic field to test sample, and detect magnetization after applied with highly sensitive resonating sample magnetometer.
-
Typhoon HIL, Inc.
Onboard 192 pin snap-in terminal dramatically simplifies the wiring between your control hardware and your HIL system. As soon as the system is up and running there are 192 test terminals for easy access to all the interface signals: firing pulses, control feedback signals and other analog/digital I/O signals.
-
Exosens Group
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
777531-01 -
NI
The PCI‑6602 performs encoder position measurements, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features eight counter/timers, digital debouncing filters, … and TTL/CMOS-compatible digital I/O. The PCI‑6602 can perform three simultaneous high-speed DMA transfers.
-
782351-01 -
NI
The PCIe‑6612 performs encoder position measurement, event counting, period measurement, pulse-width measurement, pulse generation, pulse-train generation, and frequency measurement. It features eight counter/timers, digital debouncing filters, and TTL/CMOS-compatible digital I/O. The PCIe‑6612 can perform three simultaneous high-speed DMA transfers.
-
SD Series -
L. A. B. Equipment, Inc.
The need for products to survive various shock levels in an operating environment requires in-house testing of products during design and evaluation stages. L.A.B. Equipment, Inc.''s SD-series of mechanical free-fall test systems produces accurate and repeatable half-sine, squarewave and sawtooth pulses in accordance with military and industry specifications.