Showing results: 676 - 690 of 1197 items found.
-
Taylor Dynamometer, Inc.
Each of the four models available offers excellent dynamic response due to the low moment of inertia and high pulse torque. Advanced control capabilities allow for motoring or absorbing to provide variable road load simulations and simulated terrain. Also equipped with a positioning encoder, our AC Chassis Dynamometers allow a top recommended speed of 90 mph (145 kph) at full load.
-
Rohde & Schwarz GmbH & Co. KG
R&S broadband amplifiers are innovative solid-state solutions with exceptional RF performance for generating RF power up to 13 kW in the frequency range of 4 kHz to 6 GHz. Designed as very compact amplifiers, at highest power density, they are robust against severest output mismatch while featuring high availability. Applications range from amplitude, frequency, phase, pulse to OFDM modulation.
-
GX1110 -
Marvin Test Solutions, Inc.
The GX1110 is a high performance, single-channel PXI arbitrary waveform generator that offers function generator and arbitrary waveform generator functionality within one instrument. Built-in waveforms are available for use with both the DDS or AWG modes of operation and include Sine, Triangle, Ramp, Noise, Gaussian pulse and Sinx / x. A flexible sequencer is also available as part of the AWG's architecture, supporting the generation of complex waveforms.
-
N6752A -
Keysight Technologies
The Keysight N6752A is a 100 W high-performance, autoranging DC power module that provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. Optional high-speed test extension offers an oscilloscope-like digitizer that increases measurement accuracy when viewing high-speed transient or pulse events within the device-under-test (DUT).
-
N6756A -
Keysight Technologies
The Keysight N6756A is a 500 W high-performance, autoranging DC power module that provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. Optional high-speed test extension offers an oscilloscope-like digitizer that increases measurement accuracy when viewing high-speed transient or pulse events within the device-under-test (DUT).
-
N6751A -
Keysight Technologies
The Keysight N6751A is a 50 W high-performance, autoranging DC power module that provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. Optional high-speed test extension offers an oscilloscope-like digitizer that increases measurement accuracy when viewing high-speed transient or pulse events within the device-under-test (DUT).
-
N6755A -
Keysight Technologies
The Keysight N6755A is a 500 W high-performance, autoranging DC power module that provides low noise, high accuracy and programming speeds that are up to 10 to 50 times faster than other programmable power supplies. Optional high-speed test extension offers an oscilloscope-like digitizer that increases measurement accuracy when viewing high-speed transient or pulse events within the device-under-test (DUT).
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
CYHCS-D8 -
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
Vektrex Electronic Systems
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Thermo Fisher Scientific Inc.
Identify and help correct ESD and latch-up susceptibility issues on sensitive integrated circuit components prior to full-scale production with the Thermo Scientific™ MK.2-SE ESD and Latch-Up Test System. The MK.2-SE test system provides advanced capabilities to test high pin count IC devices to Human Body Model (HBM) and Machine Model (MM) ESD standards. The system’s pulse delivery design addresses wave form hazards such as trailing pulse and pre-discharge voltage rise, and performs Latch-Up testing per the JEDEC EIA/JESD 78 Method.
-
MFCh -
Holding Informtest
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
TM1000 -
T&M Tools Limited Co
Designed to aid in the testing of fiber optic cable when using an OTDR. The OTDR LaunchFiber box is used with Optical Time Domain Reflectometers (OTDR's) to help minimize the effects of the OTDR's launch pulse onmeasurement uncertainty.
-
MPA-XL -
CDP Systems Corp.