Filter Results By:

Products

Applications

Manufacturers

Pressure

Force exerted over it's given surface area.

See Also: Differential Pressure, Absolute Pressure


Showing results: 1756 - 1770 of 1792 items found.

  • Efficient All-In-One Test Solution for Low-Cost IoT Devices

    KT RFCT 2400 - Konrad Technologies GmbH

    The low price point creates a cost effective means for testing wireless communication units, while generating a favorable cost to performance ratio.‍The calibrated RF test system has a small footprint, integrating seamlessly into test system infrastructures via a single Ethernet connection. GPIOs control the DUT and peripherals. The test system enables communication interfaces like SPI, I2C, UART and CAN. Simple Go/No-Go tests can be performed in parallel. The KT-RFCT 2400A features a 70 MHz to 6 GHz frequency range and includes non-signaling and signaling connections. Bluetooth signaling standards are supported up to 4.1 as well as BT-LE. WIFI signaling standards supported are a, b, g, n and ac.‍The KT-RFCT 2400A is the perfect test system for a wide range of applications, such as Bluetooth, Infotainment, Keyless Entry, Tire Pressure Measurement, GPS and WIFI.

  • Instruments

    Lambient Technologies

    Organizations working on new thermosets or new thermoset formulations need an intimate understanding of how these materials cure before they can proceed to the next step in the research, quality control, or production process. What happens when the material is heated? When is the best time to apply pressure to squeeze out voids? How fast does the material react at 120C? 150C? 180C? Most organizations today address this need by curing a sample for an arbitrary amount of time before using inexact, error-prone manual methods, or complex thermal analytical instruments to test cure state. Maybe the sample has reached the end of cure, but maybe not. With traditional methods, it’s difficult to tell for sure. How can organizations determine whether they’re processing materials longer than necessary? Dielectric cure monitoring lets them know for sure.

  • Level System

    Universal II - AMETEK Drexelbrook

    The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.

  • FEA and Strain Gauge Testing

    Circuit Check, Inc.

    Circuit Check began Strain Gauge Testing in 1999 when BGA/SMT technology started replacing PTH components, reducing strain levels was a reactive post fixture fabrication process. We quickly recognized that the “reactionary” process was neither efficient nor were we capable on knowing the lowest achievable strain levels. Our engineering team came up with visual tools utilized during design to easily identify areas of excessive probe force, though still not enough data was generated to identify the lowest possible strain. Finite Element Analysis software models the PCBA and test fixture and applies the pressures from test probes and board supports and indicates the micro strain level applied to the PCBA. Using the FEA software during our design process allows our engineers to modify fixture designs to attain the lowest possible micro strain before fabrication begins.

  • Laser Spectroscopic Motor Exhaust Gas Analyzer

    MEXA-ONE-QL-NX - HORIBA, Ltd.

    The MEXA-ONE-QL-NX is an analyzer for the direct, simultaneous real-time measurement of the four relevant nitrogen-containing exhaust gas components NO, NO2, N2O and NH3.The analyzer combines a light source based on the new quantum cascade technology (efficient lasers in the mid-infrared spectral region) with a precisely adjusted dual path cell to measure low concentrations with maximum sensitivity. The detection limit complies with current European legal requirements.Furthermore, the MEXA-ONE-QL-NX offers wide measuring ranges of up to 5000 ppm (for NO). By using extremely narrowband light sources and measuring under reduced pressure the cross-sensitivity to other exhaust gas components can be drastically minimized.The complete measuring system - including filtration - is specifically developed for the measurement of NH3 and thus guarantees a very fast NH3 rise time (T10-T90) of less than 5 seconds. The MEXA-ONE-QL-NX can be operated as a stand-alone analyzer or integrated into the MEXA-ONE software interface for user-friendly and simplified system operation.

  • Handheld Water Quality Meters

    LAQUA DO220 - HORIBA, Ltd.

    Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsWith real-time clock and date/time stamp for GLP complianceAuto log data; built-in memory can store up to 1000 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmPhono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty

  • pH & ORP Sensors

    Barben Analytical

    The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.

  • Hazardous Location Syringe Pump

    100HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compat​ible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    1000HLf - Teledyne LABS

    The Teledyne ISCO HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    500HLf - Teledyne LABS

    The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    260HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Integrated Gas Alarm & Control System

    MCX-32 - Teledyne Gas & Flame Detection

    The MCX-32 controller features a flexible design that allows the user to customize a system by choosing from a selection of individually addressable field devices or use addressable input and output modules. Detcon’s full range of gas sensors (purchased separately) can be used to create a gas detection system consisting of toxic gas, combustible gas, and/or oxygen deficiency. A wide range of field devices such as liquid level, temperature, pressure, flow, etc., can also be configured for input to the control system. Four standard I/O modules are available: a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). I/O modules are din-rail mounted and stackable allowing for seamless system expansion. The I/O modules may be mounted within the main system enclosure or in separate enclosures suitable for the area classification where installation will occur. In many cases using distributed I/O nodes can significantly reduce wiring and installation costs.

  • Salt Spraying Test Chamber

    Sanwood Environmental Chambers Co ., Ltd.

    Sanwood is glad to be the ODM/OEM manufacturer of Salt Spraying Chamber,Salt Spray Test Chamber,salt spraying test chamber,Salt spraying chamber,Salt spraying chamber sales enterprises all over the world! 1:It adopts 5mm or 8mm imported gray and white impact resistant P.V.C board, with high temperature resistance up to 85℃ and corrosion resistance. 2:Support frame: ¢ 10MM fiberglass rod, corrosion resistant. The steel V-frame and the fiber rod angle are placed to ensure the specimen is inclined at 15-30 degrees. 3:Pressure barrel is welded seamlessly with 2.0MMSUS304 stainless steel plate 4:The heating adopts titanium alloy electric heating tube. It has high corrosion resistance and long service life is 3-5 years higher than ordinary stainless steel heating tube. 5:The cover is made of 5MM imported transparent (Germany YLIS) acrylic sheet. It has fine workmanship, beautiful appearance and high transparency.

  • Rack Mounted Load Banks

    Junxy Energy

    Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.

  • MOTUS Stand-Alone Sensor

    Aanderaa Data Instruments AS

    There are numerous ways of measuring Ocean Waves. At Aanderaa, we focus on three measurement types: pressure, acoustic, and motion. In this section, we cover the motion-based sensors in the MOTUS family.MOTUS Directional Wave Sensor is suitable for integration on different buoy types. It is intended for commercial as well as research use. The directional stand-alone Sensor processes wave data and is configurable to directly present parameters and wave spectrum. The sensor can be connected to a SmartGuard using the CANbus-based AiCaP protocol. It can also be connected to a PC or third-party systems through the RS-232 interface.MOTUS Wave Height Sensor is for wave height only. As the MOTUS Directional Sensor, it is suitable for integration on different buoy types. In the sensor, the directional wave parameters are locked. It is possible to open the wave direction parameters with a software license from Aanderaa later if the need changes. MOTUS Lite OEM Sensor is the OEM version of the MOTUS Directional Wave sensor. It is delivered as an electronic board without housing and cables. Please get in touch with the factory for more options and restrictions.

Get Help