Showing results: 106 - 120 of 165 items found.
-
18534PS1 -
Carl E. Holmes Company
Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
UC9710xx -
UC Instruments, Corp.
The UC8710C, UC9710L and UC8710CL tunable laser modules offer superior performance in testing DWDM components, AWG & PLC components, and optical amplifiers, and performing other general- purpose fiber optical test and measurement applications particularly in fiber grating sensor fast sweep testing.
-
GM82009xx -
UC Instruments, Corp.
The GM82009C, GM820093L and GM82009CL tunable laser modules offer superior performance in testing DWDM components, AWG & PLC components, and optical amplifiers, and performing other general- purpose fiber optical test and measurement applications particularly in fiber grating sensor fast sweep testing.
-
Falcon Electric, Inc
*UPS Monitoring. Falcon’s Dry Contact Relay Card facilitates UPS status via configurable relay contact activation for simple integration into existing PLC/ monitoring systems.*Flexible Configuration. Easily installs into all SSG and SSG-RP UPS models. Configurable to allow simple selection of active open or closed relay contacts.*Notification & Remote Shutdown Capability. Provides relay contact activation during a UPS event including utility power loss, low battery, UPS fault and bypass condition. Supports safe shutdown of the UPS after a utility power loss event.*Simple Integration. The detachable connection facilitates simple integration into existing programmable logic controller (PLC) or management systems.
-
Avista Realtime Systems, LLC
If you are an Industrial Control engineer or technician dealing with Modbus RTUs, PLCs, Drivers and SCADA servers, you must have Modbus TCP Plant Simulator is your toolbox. With this tool, you can test and verify your SCADA tag names, IO Server mappings, Modbus addresses, alarms, visualization displays, historians, reports, data communication channel throughput, controls, and more without deploying even one RTU or PLC.
-
Panasonic Automotive & Industrial Systems Europe GmbH
The Panasonic product portfolio comprises both low-cost compact programmable controllers with little space requirement which are suitable for many basic tasks and high-end PLCs like the flagship FP7.A multitude of useful functions has been successfully integrated into the compact PLCs so that they offer many of the advantages of a modular high-end PLC such as analog control, network communication, and positioning control. All Panasonic PLCs offer an outstanding price-performance ratio.
-
Lisun Electronics Inc.
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
Metrix
Seismic signal conditioners are designed to accept an input from (and provide power to) a seismic sensor. They convert the signal to a proportional 4-20mA DC signal that can be used as an input to process control instrumentation such as a PLC or DCS. They provide additional convenience features such as optional displays, BNC connectors for access to the dynamic sensor signal, and bandpass filtering. Metrix offers seismic signal conditioners that can accept either acceleration or velocity sensors, and are available with or without an integral display.
-
Acopian Technical Company
Contacts to control an external horn or light, or to signal your PLC are now available on independent accessories for any power supply. These modules can be used on power supplies with DC voltages from 5 to 125 Vdc. SPDT relay contacts switch if the power supply’s output deviates by:*1.0 volt or more (for 5 volt outputs)*2.0 volts or more (for 6 to 48 volt outputs)*3.0 volts or more (for 49 to 125 volt outputs)
-
Rishabh Instruments Pvt. Ltd.,
Module of logic outputs. Control of actuators from monitoring systems or PLC over RS485. 4 relay outputs or 8 OC outputs steered through RS-485/Modbus. Fixing on a TS35 rail. Full galvanic separation between outputs (for relay outputs). Configuration through free LPConfig software.
-
Shanghai MCP Corp
.AC/DC withstand voltage test & ground bond test .Insulation resistance test(ST60).Arc detection.Zero crossing turn-on,turn-off operation switch.Controllable ramp-up time .Ture RMS cut-off current measurement .Automatic fail indicator of alarm lamp and buzzer.VFD display.Standard PLC interface .Option RS-232,RS-485
-
ETV-SERIES -
Envisys Technologies
Environmental Chamber with Vibration Shaker Interface provision consists of Environmental Test Chamber, Vibration Shaker Interface Provision, HMI/PC PLC based Control System etc., This chamber is designed with unique features to meet the control parameters like Temperature, Humidity (optional) and 3 Axis Vibration Controls which are specified in the specification.
-
Datexel
The Datexel range of Data Acquisition equipment includes Modbus RTU Masters and Slaves, Modbus Input, Modbus Output Modules, Modbus Isolation Modules and Modbus Repeaters. The range also includes converters (RS485, USB, RS232, RS422, TCP-IP). By combining these units with the DAT3000 and DAT10000 series a complete solution for your Data Acquisition can be found from Datexel. The DAT9550 is a remote Modbus display unit that can be programmed to accept data from Modbus slaves or masters such as a PLC or the DAT9000 range of Modbus controllers.
-
GLT400 -
Graphtec Corporation
*Transferring data to PLC via Modbus/TCP protocol*DC Power only for -20 to +60 operation*Supports WEB server, FTP server and FTP client network functions for remote monitoring and controlling*High Isolation inputs to ensure signals are not corrupted by noise from other channels*Connect as a remote terminal unit of GL840
-
SY024 -
Synectic Electronics
The SY024 Frequency Scaler/Multiplier can be linked to most frequency generating devices. It can be set to multiply or divide the frequency by a simple set up. When a frequency output device like a flow meter gives insufficient pulses to give the accuracy you need, or too many pulses for your Programmable logic controller or frequency counter to handle, or if you have more than one frequency output device and the rates are different you can match them by multiplying or dividing and re-transmitting to match the outputs to one another or the capabilities of your PLC etc.