Filter Results By:

Products

Applications

Manufacturers

Oil Dielectric

measures the breakdown voltage of insulating oils.

See Also: Oil Dielectric Test


Showing results: 31 - 45 of 68 items found.

  • Transformer Insulation Testing

    Megger Group Ltd.

    The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).

  • Dielectric Strength Meter

    Dielectrotest - Amperis sl

    The Dielectrotest is a fully automatic dielectric oil meter for determining the breakdown voltage of insulating liquid. It is designed for both laboratory and field use for commissioning and maintenance purposes. The test standard is selected via menu.

  • Precision Test Cell for Liquid Insulant

    RY1 & SG121 - Shanghai Jiuzhi Electric Co., Ltd.

    This precision test cell measures the dielectric properties of liquid insulants like insulation oil etc.The test cell is designed as a vacuum-sealed cylindrical capacitor with shielded measuring electrode. The cell should be used with SG121 when heating.

  • Oil Withstand Voltage Tester

    TE 6080 - Wuhan Sangao Electrical Test Installations Limit Co.

    TE6080 Automatic insulating Oil Tester, in accordance with IEC156, realizes the full automatic determination of insulating oil dielectric strength, make the original tedious and dangerous work become safe and easy. The instrument adopts special software and hardware anti-interference measures to eliminate the competing products prone to crash phenomenon. The new design will reduce the volume to the 1 / 2 of original, easy to carry and operate on-site.

  • Dielectric Strength Tester

    HY - Chongqing Lushun Scientific & Technological Development Co., Ltd.

    The instrument is designed and made as per the National Standard GB/T 507 "Test Methods for Breakdown Voltage of Lubricating Oil". It can be widely used to determine dielectric constant of lubricating oils in the field of railway, aviation, power plant, petroleum industry, and scientific institutes.

  • Automatic Dielectric Constant Tan Delta And Resistivity

    Sivananda Electronics

    No Balancing and Calculation required to calculate Volume / Surface Resistivityand Dielectric Constant.Complies IEC 60250, IS 4487, Test jig Conform to ASTMD 257Built in Thermal PrinterSerial port RS232 for data downloading.Can be used to check liquid sample with Three Terminal oil cell.Storage 100 Test reports

  • High-Voltage DC Power Supplies

    Excelitas Technologies Corp.

    Higher-voltage and Higher-power Supplies require more complex design solutions. The heat to be dissipated and installation infrastructure, plus choice of insulation system in a HVPS are driven by the output voltage and output power which ultimately dictates packaging. Typical insulation systems are based on air, dielectric oil, epoxy, RTV Silicone and even Sulfur Hexafluoride (SF6). The method of cooling is a factor as well, the choices often coming down to air, water or oil, depending on the platform design requirements. These applications require Excelitas' detailed understanding to help choose the best design solution.

  • Pressure Balanced, Oil-Filled Hose

    PBOF - Teledyne Marine ODI

    ​Pressure Balanced, Oil-Filled (PBOF) hose assemblies from Teledyne ODI are designed and qualified to accepted industry standards. The double-walled hose design incorporates inner and outer elastomeric barriers with fiber reinforcements to withstand the demands of long performance life requirements in deep ocean interconnect and distribution applications. The hose is filled with non-conductive silicone oil, which acts as a pressure compensator and dielectric. The electrical and/or optical conductors are loosely housed within the oil-filled assembly.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Automatic Oil Tan Delta & Resistivity Kit

    MOTR - The Motwane Manufacturing Company

    Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.

  • Fully Automatic Transformer Oil Test Set

    Neutronics Manufacturing Co.

    1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.

  • Dissolved Gas Analysis Monitor

    doblePRIME Delphi - Doble Engineering

    The doblePRIME Delphi is a dissolved gas analysis (DGA) monitor that helps you track transformer health by providing early warning signs of problems such as overheating, insulation degradation or mechanical movement within the transformer.The doblePRIME Delphi provides this valuable information in real time, second by second, through analysis of the insulating oil.

  • Oil & Fuel Analysis

    BETA Laboratory

    BETA Laboratory is strongly positioned to supply superior analytical results foryour Insulating Oil, Lubricating Oil and Fuel Oil samples. As a provider to fossil,nuclear and alternative fuel generating facilities as well as industrial and commercialbusinesses, we deliver accurate results in accordance with ASTM Standards, driven bystringent ISO 9001 and nuclear quality control programs.

  • Oil Tan Delta Test Set

    Megger Group Ltd.

    The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.

  • Resistivity Meter

    Eltel Industries

    Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC

Get Help