Showing results: 31 - 45 of 489 items found.
-
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
OCMA-500 -
HORIBA, Ltd.
OCMA-500 to measure concentration of oil contained in drainage and environmental water.After injecting the water sample and solvent, all you have to do is press the start button,and the system will automatically conduct the monitoring operation from oil extraction to sample measurement and draining. With no more troublesome operations like opening/closing the drainage valve, monitoring is speeded up.In addition, the color graphic LCD and the backlit extraction tank have improved operability.
-
InfraCal 2 ATR-SP -
Ametek Spectro Scientific
The InfraCal Model ATR-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels when using hexane, pentane or Vertrel MCA as the extracting solvent. Measurement data obtained with this analyzer will correlate to EPA Method 1664 as both procedures are based on evaporation techniques and measuring the residual oil and grease. The analyzer is equipped with a built-in cubic zirconia horizontal attenuated total reflection (HATR) stainless steel sample stage. The InfraCal 2 ATR-SP is a direct replacement for the original InfraCal HATR-T2 used worldwide for the determination of TOG/TPH in water and soil.
-
doblePRIME DOMINO -
Doble Engineering
The doblePRIME DOMINO provides real time data for moisture in oil, giving indications of relative saturation or absolute ppm levels. This is useful information, especially when a transformer is being loaded in excess of nameplate or when the transformer is undergoing abnormal load cycles.
-
MiniLab 23 -
Ametek Spectro Scientific
With two simple tests, the MiniLab 23 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions.
-
MiniLab 33 -
Ametek Spectro Scientific
With three simple tests, the MiniLab 33 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions
-
LD-LOGA-A10 -
Labodam
Oil and Grease analyzerLD-LOGA-A10is a tabletop analyzer with a sample testing range of0.12 mg/L to 840 mg/L. The unit displays and prints the sample spectra, position and wavenumber of the absorption peak. It features self-contained optical and electrical system withhigh degree integration. Testing data and spectrograms can be saved to hard disk forchecking and printing anytime Sensor signal processing uses lock-in amplifier circuitimproving the analyzer’s SNR and the minimum detection limit.
-
InfraCal 2 TRANS-SP -
Ametek Spectro Scientific
The InfraCal 2 TRANS-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels using the traditional EPA methods 413.2 and 418.1 or ASTM method D7066-04 and Freon-113, hydrocarbon-free grade of perchloroethylene, AK-225, S-316 or other spectroscopic infrared transparent solvent as the extracting solvent. Since the extract is deposited into a 10 mm quartz cuvette cell with Teflon stopper, light end volatile components are retained for measurement. Accurate down to 0.1 ppm.
-
Lumirati
The faster, safer and easier way to locate even tiny leaks in industrial air conditioning and refrigeration systems. Lumirati® bottled dyes can be poured directly into any AC&R system. The dye can remain safely in the system to confirm repairs and perform future preventive maintenance checks. Lumirati® Leak Detection Oil is the only dye that gives you all these benefits:- Universal dye that is compatible with all refrigerants and lubricants- OEM-approved by major compressor, refrigerant, lubricant and AC&R equipment manufacturers- Co-solvent free so dye will not impair lubricant properties, which could lead to excessive wear or damage to the system components
-
MicroLab 40 -
Ametek Spectro Scientific
MicroLab 40 is designed primarily for fleets operating equipment with hydraulic components or heavy equipment gears and transmissions. This would include off-road mining and construction vehicles as well as over-the-road equipment with hydraulics such as bucket trucks, fire engine ladder trucks or solid waste trucks. The MicroLab 40 is also used in applications for offshore drilling equipment. In addition to the basic oil chemistry and extended elemental analysis provided with the MicroLab 30, the MicroLab 40 model includes a particle counter which provides critical analysis for cleanliness of hydraulic oils and gear oils to determine the health of those oils and mechanical condition of those components.
-
-
Weshine Electric Manufacturing Co., Ltd
Automatically complete the operations of extractant addition, neutralization titration and end point discrimination, acid value calculation, data storage and print output.
-
AJIT Electronics Co.
Theses tester sets are used for determining the di-electric BDV of insulating oils, both new and in-service from transformers, switchgear and other electrical equipments.
-
BAUR Prüf- und Messtechnik GmbH
Insulating materials are the elixir of life of electrical equipment. These materials lose their insulating and cooling properties due to impuri ties and ageing. This damages equipment, causes failures and is consequently often accompanied by high costs. Precise and reliable measurement results.
-
Kharkovenergopribor Ltd.
The main functions of electrical insulating oils are heat dissipation and reliable insulation of energised parts of electrical installations. During the normal operation, moisture and other impurities penetrate into insulating oils, leading to a deterioration of their dielectric properties. This in turn may result in catastrophic failures of critical electrical equipment.