Showing results: 5986 - 6000 of 9914 items found.
-
60-553-005 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-553-006 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-553-003 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-553-007 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-553-008 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
EXC-4000P104plus -
Excalibur Systems, Inc.
The EXC-4000P104plus is a multiprotocol P104plus interface board for embedded applications or avionics test and simulation applications. Each board holds up to five independent modules. Two on-board modules use the MIL-STD-1553 communications protocol (M4K1553Px); another on-board module uses the ARINC-429 communications protocol; two additional detachable modules can be any one of the following types:M4K1553PxS (Single Function - RT validated) This module operates as a Bus Controller, Remote Terminal or a Bus Monitor. This module qualifies for airborne applications.M4K1553Px (Multi Function) This module operates as a Bus Controller, up to 32 Remote Terminals and as a Bus Monitor. Supports an Internal Concurrent Monitor in RT and BC/RT modes.M4K1553Px(S)-1760 Same as M4K1553Px(S) plus MIL-STD-1760 options.M4KMMSI Mini Munitions Store Interface module. Supports RT, BC/Concurrent-RT/Concurrent Monitor and Bus Monitor modes. Up to 8 hub ports EBR-1553 [10 Mbps 1553 protocol using RS-485 transceivers] and 1 monitor output.M4KH009 Based on our H009 family. This module operates as a Central Computer Complex (CCC) and/or up to 16 Peripheral Units (PUs) simultaneously, or as a Bus Monitor. In addition, a Concurrent Bus Monitor enables concurrent monitoring of the bus during CCC and PU simulation.M4K429RTx Based on our ARINC 429RxTx board. This module supports either five or ten ARINC 429 channels each of which can be configured in real time as a receive or transmit channel.M4K708 This module supports two channels of ARINC 708/453, each one selectable as either transmit or receive.M4KSerial This module supports up to 4 independent channels of serial communications, each of which can be selected as RS485, RS422 or RS232.M4KDiscrete This module supports 20 selectable input/open collector output discretes. The module supports TTL (0 to 5 volts) or avionics (0 to 32 volts) voltage levels.M4KCAN This module supports up to 6 independent channels of CAN 2.0B protocol with standard and extended message frames and message identifiers.
-
MCX-32 -
Teledyne Gas & Flame Detection
The MCX-32 controller features a flexible design that allows the user to customize a system by choosing from a selection of individually addressable field devices or use addressable input and output modules. Detcon’s full range of gas sensors (purchased separately) can be used to create a gas detection system consisting of toxic gas, combustible gas, and/or oxygen deficiency. A wide range of field devices such as liquid level, temperature, pressure, flow, etc., can also be configured for input to the control system. Four standard I/O modules are available: a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). I/O modules are din-rail mounted and stackable allowing for seamless system expansion. The I/O modules may be mounted within the main system enclosure or in separate enclosures suitable for the area classification where installation will occur. In many cases using distributed I/O nodes can significantly reduce wiring and installation costs.
-
K- PT100/1000 -
Influx Technology LTD
Our K-PT module is designed to connect up to PT100/PT1000 sensors and simply provides an output voltage signal. Thus enabling the most standard voltage measurement devices to work with PT100/PT1000 sensors. The PT100 sensors offer excellent accuracy and repeatability.
-
PA201 -
Gasera Ltd.
Gasera’s PA201 custom gas measurement system is a gas cell with an integrated detector that can be combined with different types of laser sources, making it an extremely versatile research tool. It also includes the gas exchange module that makes it extremely easy to use.
-
TEF0008-02 -
Sundance Multiprocessor Technology Ltd.
The Trenz Electronic TEF0008 is a FPGA to Mezzanine Card (FMC) based on VITA 57.1 FMC HPC Standard, with four SFP+ 10 GBit ports for fiber optical SFP modules. It is inteded for use on a FMC HPC carrier and can not be used stand-alone.
-
Curtiss-Wright Defense Solutions
Designing a graphics-intensive application isn't an easy feat. Curtiss-Wright graphics and video modules reduce costs, speed time-to-market, and reduce program risk by providing low-power, high-reliability, rugged SWaP-optimized solutions based on modular open systems approaches.
-
XMC-WMUX -
Alta Data Technologies LLC
Alta Data Technologies’ XMC-WMUX interface module (PCI Express Mezzanine Card for Carriers and Single Board Computers or Carriers) is a single or dual-channel (A-B Redundant = 4 Busses per Channel/Wings) WMUX card supported by the latest software technologies.
-
DGH Corporation
Provide direct connection to a wide variety of sensors to any host with an RS232 or RS485 port. The modules perform all signal conditioning, scaling, linearization, and A/D conversion. They each contain some discrete digital I/O lines and can measure signals such as:
-
DA8-G9-UNIV -
Finna Sensors
Designed for semi-solids; powdered, granular or textile materials; and pliable sheets in rolls or stacks. Optional needle electrodes and sensitivity modules which allow for a wide range of moisture measurements. Rechargeable NiMH batteries save hassle and money of battery replacement.
-
ProfiMessage -
Delphin Technology AG
ProfiMessage devices have been specially developed for use as modular measurement, control and monitoring units. ProfiMessage uses a master/slave concept and has a range of I/O modules to meet the requirements of any system. This enables the problem-free functioning of multi-channel systems.