Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 9961 - 9975 of 10562 items found.

  • PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays

    M9103A - Keysight Technologies

    The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.

  • NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780181-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    779593-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • Digital Insulation Mult-Meter

    8010 IN - Standard Electric Works Co., Ltd

    ● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1

  • Voltage/Continuity Testers

    VOT-53 - Standard Electric Works Co., Ltd

    ● 2000-count digital display (LCD type).    ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function:   ACV/DCV: 1000V   Resistance: 2000Ω   Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard :     EN 61010-1 CAT III 1000V    EN 61010-1 CAT IV 600V    EN 61243-3    EN 61326-1

  • PXIe-5114, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope, 256 MB

    783591-03 - NI

    PXIe, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXIe‑5114 low-cost PXI oscilloscope has two channels that sample up to 250 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXIe‑5114 also features advanced PXI synchronization and data streaming capabilities.

  • PXIe-1086, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis

    781720-01 - NI

    PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis - The PXIe‑1086 incorporates hot-swappable, redundant AC power supplies as well as hot-swappable, front-accessible, redundant cooling fans. These high-availability features improve the mean time between failure (MTBF) and mean time to repair (MTTR) of the PXI system. The PXIe‑1086 monitors power supply health/voltages, air intake temperature, and fan health/speed; it provides any failure feedback with the status LEDs located on the chassis. This chassis is ideal for test, measurement, and control applications with demanding system uptime requirements.

  • sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780874-01 - NI

    Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.

  • PXIe-1095, 18-Slot, Up to 24 GB/s PXI Chassis

    783882-01 - NI

    PXIe, 18-Slot, Up to 24 GB/s PXI Chassis—The PXIe-1095 features a high-bandwidth backplane and 58 W of power and cooling in every slot to meet a wide range of high-performance test and measurement application needs. The chassis incorporates two hot-swappable power supplies to improve the mean time to repair (MTTR) of the PXI system; it also offers an optional timing and synchronization upgrade that includes a built-in oven-controlled crystal oscillator (OCXO) for increased clock accuracy and external clock and trigger routing. It accepts PXI Express modules in every slot and supports standard PXI hybrid-compatible modules in up to five slots.

  • sbRIO-9236, Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    781580-01 - NI

    Non-Enclosed, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The sbRIO‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The sbRIO‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. Non-enclosed modules are designed for OEM applications.

  • sbRIO-9235, Non-Enclosed, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    781579-01 - NI

    Non-Enclosed, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The sbRIO‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The sbRIO‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. Non-enclosed modules are designed for OEM applications.

  • PCI-6123, 8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O DeviceMultifunction I/O Device

    779409-01 - NI

    8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device - The PCI‑6123 is a simultaneous-sampling, multifunction DAQ device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PCI‑6123 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements. The PCI‑6123 dimensions require chassis slots that can accommodate full-length PCI modules.

  • PCI-6123, 8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device

    779408-01 - NI

    8 AI (16-Bit, 500 kS/s/ch), 8 DIO, PCI Multifunction I/O Device - The PCI‑6123 is a simultaneous-sampling, multifunction DAQ device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PCI‑6123 is ideal for a variety of applications, such as IF digitization; transient recording; ISDN, ADSL, and POTS manufacturing test in the telecom industry; ultrasound and sonar testing; and high-energy physics. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements. The PCI‑6123 dimensions require chassis slots that can accommodate full-length PCI modules.

  • PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module

    779687-01 - NI

    204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.

  • PXIe-5114, 125 MHz, 2-Channel, 8-Bit, PXI Express Oscilloscope, 8 MB

    783591-01 - NI

    PXIe, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope—The PXIe‑5114 low-cost PXI oscilloscope has two channels that sample up to 250 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require flexible measurement configurations and up to 125 MHz of analog bandwidth. The PXIe‑5114 also features advanced PXI synchronization and data streaming capabilities.