Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 8041 - 8055 of 10608 items found.

  • Field Strength Meter

    FIM-71 VHF - Potomac Instruments, Inc.

    The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • Field Strength Meter

    FIM-72A UHF - Potomac Instruments, Inc.

    The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • Power modules

    G.R.A.S. Sound & Vibration A/S

    It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation

  • PSD Signal Processing Tool

    SEEPOS - SiTek Electro Optics AB

    For most position measurement applications the SiTek SEEPOS system offers a complete and easy-to-use solution. High speed PSD electronics combined with digital signal processing and high speed USB data transfer gives a powerful measurement system. With its large dynamic range it can handle light powers from nW to mW from DC light sources as well as modulated light sources. All parameters, such as PSD bias voltage, amplifier gain, the use of analog and digital filters etc., are easily controlled from the included software and light spot position is continuously displayed both in XY and X-t, Y-t graphs. Optimized plot algorithms ensure that all data is visually seen on the screen even in full speed measurements. Included tools for data analysis and visualization simplify rapid scan through large data sets in order to find specific parts of interest.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

  • Coating Thickness Gauge

    NOVOTEST TP-1M - NovoTest

    Portable Coating Thickness Gauge NOVOTEST TP-1M – device for operative non-destructive measuring of coating thickness in compliance with ISO 2808 with high measurement accuracy.Coating thickness gauge is designed to test:thickness of various thick protective coatings on various metals and alloys;thickness of paint and other dielectrics – radioabsorbing, mastic, teflon, plastic, electroplating coatings on steel;thickness of electroplating and paint coatings on non-ferromagnetic alloys and non-ferrous metals;thickness of bitumen and other thick coatings on various metals and alloys;as well as relative humidity, air temperature, surface temperature, dew point temperature and difference between surface and dew point temperatures, estimate the depth of grooves and the surface roughnessElectronic thickness gauge – device which widely used in shipbuilding and automotive industries for measuring of the thickness of paint, in order to test the quality of products, also it used for determining technical condition of the tested objects.

  • CompactDAQ Controller

    NI

    The CompactDAQ Controller is a rugged, reliable, high-performance embedded controller with industry-standard certifications. It is ideal for performing waveform acquisition and inline software analysis while logging data to onboard or removable SD memory. C Series modules deliver high-accuracy I/O with measurement-specific signal conditioning to connect to any sensor type. The controller also offers a wide array of standard connectivity and expansion options, such as USB, Ethernet, CAN/LIN, and RS232 serial. It runs either the NI Linux Real-Time OS or Windows Embedded Standard 7. You can customize and deploy your measurement application with support for multiple programming languages, including LabVIEW, which contains over 950 signal processing and analysis functions to accelerate development. The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis.

  • Digital AC/DC Auto-Ranging Clamp Meter

    PCMT20 - Pyle Audio Inc.

    Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit

  • Fourier Transform Optical Spectrum Analyzer, 350 - 1100 nm

    OSA201C - Thorlabs, Inc.

    Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.

  • Fourier Transform Optical Spectrum Analyzer, 600 - 1700 nm

    OSA202C - Thorlabs, Inc.

    Thorlabs' Optical Spectrum Analyzers (OSAs) perform highly accurate spectral measurements. Compatible with fiber-coupled and free-space light sources, these compact benchtop instruments suit a wide variety of applications, such as analyzing the spectrum of a telecom signal, resolving the Fabry-Perot modes of a gain chip, and identifying gas absorption lines. Many commonly available OSAs use grating-based monochromators, which have slow acquisition times due to the need to mechanically scan the grating and average out noise at each wavelength. Thorlabs' OSAs acquire the spectrum via a Fourier transform using a scanning Michelson interferometer in a push/pull configuration. This approach dramatically improves the acquisition time, enables a high-precision wavelength meter mode with 7 significant figures and ±1 part-per-million accuracy, and allows the included software to provide robust statistical analysis of the acquired spectra, as explained in the Design tab.

  • Gas Filter Correlation CO Analyzer

    Model T300U - Teledyne Advanced Pollution Instrumentation

    The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.

  • HandyScope HS4 DIFF: 50 MS/s 100MHz BW, 4 Channel, USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder

    HS4-50-DIFF - TEAM SOLUTIONS, INC.

    * record length is 131060 samples * 128K samples on screen without loss of information * free settable pre trigger position, from 0 to 100% * easy time axis zoom using unique scaleable sroll bar slider * free adjustable sample frequency * vertical offset and gain adjustable with graphical shiftable and scaleable axis * WYSIWYG trigger level, slope and hysteresis adjustment using combined trigger control * Auto setup to reduce setting time with unknown signals * linear/quadratical interpolation * extended cursor measurements * all settings accessable through popup menus * storing and recalling reference signals * software math channel available * easy to use speedbutton toolbar for easy access of all functions * comment tags to mark specific events in the signal * color hardcopy supported * explanatory comments with all controls * envelope mode * averaging of signals

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL D - Tenma

    The 72-7755 CAL D from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL - Tenma

    The 72-7755 CAL from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL DU - Tenma

    The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

Get Help