Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 7801 - 7815 of 10567 items found.

  • Analog Clamp Tester (CE)

    M-3000 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *High accuracy analog display with strong taut band meter.*Meter lock function.*AC current, AC/DC voltage and resistance measurements.*Conform to IEC safety requirements.

  • True RMS Clamp Meter with DC Current

    FLIR CM46 - Teledyne FLIR

    The FLIR CM46 clamp meter is designed for commercial and residential electricians. Featuring both AC/DC measurement, the meter is equipped with a bright backlit display for use inside electrical panels. Accu-Tip™ technology delivers amperage measurements on smaller-gauged wires more accurately — to a tenth of a digit. The meter also offers MAX/MIN/AVG recording; measures DCµA, temperature, capacitance, and frequency; and has electrical field detection to help you determine voltage presence and relative strength of the field.

  • Digital Insulation Resistance Tester (CE)

    MIS-D - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *The big digital and bar graph LCD display with back light enabled easy observation. Especially useful when working in dark place.*Hand free and continuous measurements with custom made switch.*Safe design with built in automatic discharging function for any capacitors present in the circuit.*The voltage in the circuit or capacitor can be checked by warning lamp for safe insulation measurements.*Data hold and auto power off function.*Compact, light weight and heavy duty rugged case.

  • Transformer Winding Resistance Meters

    TWA Advanced Series - Amperis sl

    The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.

  • Battery Monitoring System

    BMS-3923 - Kongter Test & Measurement Co., Limited

    This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.

  • Vehicle Electromagnetic Field Test System

    Beijing KeHuan Century EMC Technology Co,.LTD

    Vehicles are the daily means of transportation for our public, and the electromagnetic pollution in vehicles has received more and more attention from the public. The newly revised mandatory standard GB27630-201X "Air Quality Evaluation Standard for Passenger Cars" intends to require the electromagnetic field in the vehicle as one of the indicators. The measurement method measures the magnetic field strength in the vehicle. Within the frequency range of 10Hz-400kHz, the electromagnetic field measurement results should meet the requirements of the public limit of electromagnetic exposure in GB8702-2014.

  • Loss Tangent M in Dielectric Oil

    TAND220A - Amperis sl

    The measuring instrument type TAND220A complies with the international standard IEC 61620. The instrument is based on the so-called "low-amplitude, low-frequency alternating current square wave method" and allows accurate measurements of conductivity and relative permittivity. Conductivity measurement in the range of 0.01 pS/m to 20,000 pS/m allows the use of this instrument for quality control of high resistivity liquids even at room temperature. The TAND220A works with a low test voltage and also with a low test current so that it does not represent a danger for the operators.

  • Essential Instruments

    Digilent Inc.

    All Digilent test and measurement devices are multi-instrument electronics tools designed to bring the benchtop to you. Digilent's portable USB scopes, logic analyzers and signal generators allow you to measure, visualize, generate, record, and control mixed-signal circuits of all kinds. Combined with our free WaveForms software, detailed documentation, and a dedicated support community, our test and measurement hardware will turn your computer into a multi-instrument circuit analysis tool, all without the physical constraints of a lab.

  • Inspection Systems

    MicroImage Video Systems

    Video Inspection Systems with?or without measurement capabilities are an excellent way to evaluate and test small items or items in?difficult to access locations. Many options are available in addition to the measurement capability. Video Inspection is used for a variety of purposes including the ability to see? and measure items that are much smaller than the eye can see or that hand tools can measure. Video systems can also reduce the eye and/or back strain associated with production environments where an operator must look in a microscope all day.

  • Mixed Signal Oscilloscope - 6 GHz, 2 Analog and 16 Digital Channels

    MSOX6002A - Keysight Technologies

    1 GHz - 6 GHz2 analog plus 16 digital channels Easily view and isolate signals on the 12.1-in capacitive multi-touch screen with Zone triggering and 450,000 wfms/s update rate Make more precise measurements with 115 Vrms noise floor at 1 mV/div (1 GHz)Get performance measurements anywhere with the portable 6-in deep size Quickly see analysis details with standard histogram and color grade View signal integrity with jitter and eye diagram analysis options

  • Mixed Signal Oscilloscope - 1-6 GHz, 4 Analog Plus 16 Digital Channels

    MSOX6004A - Keysight Technologies

    1 6 GHz4 analog plus 16 digital channels Easily view and isolate signals on the 12.1-in capacitive multi-touch screen with Zone triggering and 450,000 wfms/s update rate Make more precise measurements with 115 Vrms noise floor at 1 mV/div (1 GHz)Get performance measurements anywhere with the portable 6-in deep size Quickly see analysis details with standard histogram and color grade View signal integrity with jitter and eye diagram analysis options

  • PCI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.8 MS/s), 24 DIO PCI Multifunction I/O Device

    779109-01 - NI

    The PCI‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • Mobile HV AC Test System

    Power Diagnostix Systems GmbH

    The system stays within the load and size limitations for permission-free road use. Additionally, the matching transformer and the reactor are filled with ester instead mineral oil. Thus, it can be easily transported to a substation, power plant, or other high voltage areas for testing HV components after installation or repair. Additionally, it is applicable for condition assessment and fault investigations. PD measurements can be performed in non-shielded environments as part of the on-site acceptance test on a power transformer, or as a method to locate PD failures acoustically, or by electrical measurement.

  • NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

    779781-02 - NI

    100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.

Get Help