Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 7561 - 7575 of 10567 items found.

  • Materials Test System

    ModuLab XM MTS - Ametek Scientific Instruments

    I-V (voltage scans with current measurement - used to characterize electronic and dielectric materials)P-E (polarization / electric field - used to run hysteresis tests to characterize ferroelectric materials) High-speed pulse (used to activate charge carriers in electronic and dielectric materials)Staircase and smooth stepless analog ramp waveformsImpedance, admittance, permittivity / capacitance, electrical modulusC-V capacitance - voltage, Mott-SchottkyAutomatic sequencing of time domain and impedance/capacitance measurements

  • PXI Digital Multimeter

    NI

    PXI Digital Multimeters, or DMMs, feature AC/DC voltage, AC/DC current, 2- or 4-wire resistance, and frequency/period measurements, as well as diode tests. You can also choose a PXI DMM with an isolated, high-voltage digitizer that can acquire waveforms at sample rates up to 1.8 MS/s at full input range, up to 3 A or 1,000 V. Additionally, you can choose a PXI DMM that can perform basic inductance and capacitance measurements.

  • Energy Analyser

    DUCA-LCD - Ducati energia S. p. A.

    Energy Analyser for DIN-rail mounting (4 modules), for Single-Phase/Three-Phase systems with Graphic LCD screen, Co-generation Energy measurement and "Wide Range" Power Supply (24 - 240 Vac/dc); voltage and current waveforms and harmonics measurement and visualization; 2 digital output for pulses or alarms; 2 digital pulse input. Optional RS485 serial line interface (Modbus or ASCII_DUCBUS), Ethernet Interface (Webserver / Modbus-TCP).

  • CT Tester, Meter Tester, Circuit Analyzer

    GOLD MINER IV - EMSYST Ltd

    Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.

  • Optical Power Meter W/6 Wavelength Calibrating Spots

    Maxcom Inc.

    With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.

  • HV Test System for Patient Monitors

    LXinstruments GmbH

    HV test enclosure for testing medical products (patient monitors). Insulated test booth with large space for DUT.3 different test nests for adapting different devices.Displays from patient monitors are checked. For this, insulation tests and leakage current measurements must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.

  • Data Acquisition System - 3U 5-Slot

    DAQ-35CP0G - North Atlantic Industries

    is a preconfigured rugged system ideally suited to support a multitude of military/aerospace data acquisition applications that require "SBC-less" remote Gig-E command and control of high-density, multichannel programmable ARINC 429/575; Dual-Redundant, Quad Channel MIL-STD-1553B; CANBus (CAN 2.0 A&B or J1939); A/D Conversion; RTD Measurement; RS-232/422/485 Serial Communications; Thermocouple Measurement; Discrete I/O; Differential Transceiver and Dual-Port Gig-E Ethernet.

  • Digital Macro Vickers Hardness Tester w/ Printer

    900-398 - Phase II Plus

    The 900-398 Vickers Hardness Tester is engineered to produce a clear indentation and a more precise measurement. By means of a load cell, closed circuit system for control, the CPU controls testing force to load/dwell/unload, allowing for the highest degree of accuracy. The large LCD shows the measuring methods, the testing force, the indentation length, hardness value, the dwell time of the testing force as well as the number of the measurement on its screen.

  • Transforming Analog Circuit Breaker Testers

    MAC-21 - ETI Precision

    The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.

  • Ground Resistance Milli-Ohmmeter & Bond Meter, Portable, 10 mΩ to 20 kΩ Auto-Ranging

    R1L-C - TEGAM Inc.

    The Model R1L-C is a Ground Resistance Ohmmeter designed to measure grounding system resistance as well as soil resistivity, over ranges from 2 to 20 k full scale. These resistance measurements correspond to soil resistivity from as low as 2 -cm to as high as 600,000 -cm. The R1L-C is capable of Wenner, Fall of Potential, 62% methods as well as bond and continuity measurements. Two, three and four are standard for this instrument.

  • Oscilloscope 10 GHz, 4 Channels, 3.5 mm

    UXR0104B - Keysight Technologies

    UXR0104B Infiniium UXR-Series, is the 10 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope with the most comprehensive set of probing, analysis applications, and measurements for advanced technologies. EVM performance for wideband mmWave measurements that rivals even the best signal analyzers. UXR-Series scopes have flexible upgrades: Bandwidth up to 110GHz, Memory up to 2Gpts, DDC up to 2.16GHz, and configurable frequency extensions up to 10GHz.

  • Chemiluminescence NO/NO2/NOX Analyzer

    Model T200 - Teledyne Advanced Pollution Instrumentation

    The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.

  • DC Power Supply

    ◎PW-4063R - PINTEK Electronics

    *Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.

  • Device Current Waveform Analyzers

    Keysight Technologies

    The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.

  • Digital Multimeters

    HDM3065 series - Qingdao Hantek Electronic Co., Ltd.

    6 1/2 bit resolution;front and back multimeter input,measure a key switch;statistic analysis、 histogram and run chart display function;Double display measurement function,display 2 kinds of signal parameters at the same time;3A/10A current range;4.3 inch 64K LCD;0.1uV resolution,easy to use,parameters can be setted easily; 13 kinds of measure functions:DC Voltage, AC Voltage, DC current, AC current, 2 line resistance, 4 line resistance, capacitance, diode, connectivity, frequency, period, Arbitrary sensor, temperature.

Get Help