Showing results: 361 - 375 of 1959 items found.
-
40-511-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-511-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-511-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-505-001 -
Pickering Interfaces Ltd.
This range of medium density PXI matrix modules (40-505 thru 509) are able to switch up to 2 Amps or 300VDC/250VAC and come in42x4, 32x6, 25x8, 18x12 and 14x16 options. The modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 160-pin DIN 41612, 78-pin D-type or 50-pin D-Type connector that is fully supported by the wide range of our cable and connector accessories.
-
40-551-002 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
40-551-001 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, also available with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
40-551-003 -
Pickering Interfaces Ltd.
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
40-522-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 12x8, 1-pole matrix - it is also available inreed relayformats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable forswitching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems.The two banks may be used for operating a 4-wire measurement system (bank-1 for source,bank-2 for measure). Larger matrices may be constructed by daisy chaining the commonsignals from multiple PXI Modules.
-
40-522-022 -
Pickering Interfaces Ltd.
Medium density PXI dual 12x8, 2-pole matrix - it is also available in reed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-584-001 -
Pickering Interfaces Ltd.
Our model 40-584, along with the following models40-584, 40-585, 40-586A and 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
40-523-022 -
Pickering Interfaces Ltd.
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
40-586A-001 -
Pickering Interfaces Ltd.
Our model 40-586A, along with the following models40-584, 40-585, 40-587Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
40-524-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
50-513A-021 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.
-
50-513A-022 -
Pickering Interfaces Ltd.
The 50-510A series of matrix cards feature a wide range of switching configurations (22x4, dual 20x4, 22x8 and 44x4). Larger matrices may be constructed by daisy chaining the common signals from multiple cards. Expansion cables are available for the 50-512 and 50-513: The 50-512 can be expanded to 44x8 or the 50-513 can be expanded to 88x4 using two cards linked by the ribbon cable assembly 50-976-020-0.1M. Also the 50-512 can be expanded to 22x16 or the 50-513 can be expanded to 44x8 using two cards linked by the ribbon cable assembly 50-976-050-0.1M.