Showing results: 181 - 195 of 1959 items found.
-
60-550-025 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
40-525A-001 -
Pickering Interfaces Ltd.
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.
-
40-535-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
40-536-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
40-537-021-S -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-519B-002 -
Pickering Interfaces Ltd.
The 40-519B-002 is a 32x4 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.
-
40-533A-022 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-533A-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
60-310-302 -
Pickering Interfaces Ltd.
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
60-310-202 -
Pickering Interfaces Ltd.
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
40-548-001 -
Pickering Interfaces Ltd.
Model 40-548-001 is a high density single 1-pole 20x4 power matrix module. It is also available in single 10x4, dual 10x4 or single 10x8 relay formats: Typical applications include power routing in Functional ATE systems, specifically automotive electronics, for example testing of Engine Management Units.
-
40-332-002 -
Pickering Interfaces Ltd.
Designed for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. This range is available in 12x2 or 6x4(shown here)matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
40-534A-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
40-534A-021-S -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
40-534A-022 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.